Monitoring of Free Flaps with Combined Tissue Spectrophotometry and Laser Doppler Flowmetry in an Animal Experimental Model

被引:4
|
作者
Berggren-Olsen, Mette Marie [1 ,2 ]
Rauff-Mortensen, Andreas [3 ,4 ]
Holst, Rene [2 ,5 ]
Houlind, Kim Christian [2 ]
Birke-Sorensen, Hanne [1 ,6 ]
机构
[1] Kolding Cty Hosp, Dept Vasc Surg, DK-6000 Kolding, Denmark
[2] Univ Southern Denmark, Inst Reg Hlth Res, Odense, Denmark
[3] Aarhus Univ Hosp, Dept Anaesthesiol & Intens Care Med, Aarhus, Denmark
[4] Aarhus Univ Hosp, Res Ctr Emergency Med, Aarhus, Denmark
[5] Univ Oslo, Oslo Ctr Biostat & Epidemiol, Oslo, Norway
[6] Aarhus Univ Hosp, Inst Clin Med, Aarhus, Denmark
关键词
free flap; monitoring; O2C; BREAST RECONSTRUCTION; PERFORATOR FLAPS; EXPERIENCE; OXYGENATION; THROMBOSIS; ARTERIAL; OXIMETRY;
D O I
10.1055/s-0037-1603735
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background When mobilizing free flaps, postoperative monitoring of perfusion is crucial to detect ischemia. Continuous monitoring may be feasible by applying a combination of tissue spectrophotometry and laser Doppler flowmetry (oxygen-2-see [O2C]). Material and Methods On 10 pigs, two symmetrical myocutaneous flaps were mobilized on each side of the abdomen based on the deep inferior epigastric vessels. Flaps were randomized to clamp either the artery or the vein and measurements using O2C were performed before, during, and after the intervention yielding information on blood flow, saturation (sat), and relative tissue hemoglobin (rHgb) concentration. Results Baseline values were similar in all groups. Introduction of ischemia caused a rapid decline in arterial ischemic flaps which all reached threshold levels in 3 minutes, whereas that was only the case for three of six venous ischemic flaps. Venous clamping resulted in a decline in sat, while the response to arterial clamping was an initial decline followed by an increase in sat. In all arterial ischemic flaps, rHgb concentration either decreased or remained at baseline levels but increased in all venous ischemic flaps. The median time to a 30% rise was 1 minute at an 8-mm depth. The rate of decreasing flow along with the rHgb measurements made it possible to distinguish the arterial ischemia (AI) from the venous ischemia (VI) within the first few minutes. Conclusion In this animal experimental model, O2C measurements of blood flow reliably detected ischemia. By adding information about rHgb, it was possible to distinguish between AI and VI.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 50 条
  • [31] THE EFFICACY OF POSTOPERATIVE MONITORING: A SINGLE SURGEON COMPARISON OF CLINICAL MONITORING AND THE IMPLANTABLE DOPPLER PROBE IN 547 CONSECUTIVE FREE FLAPS
    Rozen, Warren M.
    Chubb, Daniel
    Whitaker, Iain S.
    Acosta, Rafael
    MICROSURGERY, 2010, 30 (02) : 105 - 110
  • [32] Intraoperative Vascular Neuromonitoring in Patients with Subarachnoid Hemorrhage: A Pilot Study Using Combined Laser-Doppler Spectrophotometry
    Schmitz, Emilija
    Bischoff, Barbara
    Wolf, Dennis
    Schmitt, Hubert J.
    Eyupoglu, Ilker Y.
    Roessler, Karl
    Buchfelder, Michael
    Sommer, Bjoern
    WORLD NEUROSURGERY, 2017, 107 : 542 - 548
  • [33] Remote monitoring of head and neck free flaps using near infrared spectroscopic tissue oximetry
    Starr, Nicole C.
    Slade, Emily
    Gal, Thomas J.
    Adekunle, Ayooluwatomiwa
    Bigler, Diana
    Cheung, Brian
    Wang, Duane
    Yeoh, Melvyn
    Liau, James
    Kejner, Alexandra
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2021, 42 (01)
  • [34] Self-repaired Process of a Traumatized Maxillary Central Incisor with Pulp Infarct after Horizontal Root Fracture Monitored by Laser Doppler Flowmetry Combined with Tissue Oxygen Monitor
    Liao, Qian
    Ye, Wenjun
    Yue, Junli
    Zhao, Xiaoxi
    Zhang, Ling
    Zhang, Lan
    Huang, Dingming
    Zheng, Qinghua
    JOURNAL OF ENDODONTICS, 2017, 43 (07) : 1218 - 1222
  • [35] POSTOPERATIVE MONITORING OF LOWER LIMB FREE FLAPS WITH THE COOK-SWARTZ IMPLANTABLE DOPPLER PROBE: A CLINICAL TRIAL
    Rozen, Warren M.
    Enajat, Morteza
    Whitaker, Iain S.
    Lindkvist, Ulrica
    Audolfsson, Thorir
    Acosta, Rafael
    MICROSURGERY, 2010, 30 (05) : 354 - 360
  • [36] A Prospective Analysis of Free Flap Monitoring Techniques: Physical Examination, External Doppler, Implantable Doppler, and Tissue Oximetry
    Lohman, Robert F.
    Langevin, Claude-Jean
    Bozkurt, Mehmet
    Kundu, Neilendu
    Djohan, Risal
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2013, 29 (01) : 51 - 56
  • [37] Laser Tissue Welding in Lung and Tracheobronchial Repair An Animal Model
    Bleier, Benjamin S.
    Cohen, Neri M.
    Bloom, Jason D.
    Palmer, James N.
    Cohen, Noam A.
    CHEST, 2010, 138 (02) : 345 - 349
  • [38] Direct comparison of postoperative monitoring of free flaps with microdialysis, implantable cook-swartz Doppler probe, and clinical monitoring in 20 consecutive patients
    Frost, Markus Winther
    Niumsawatt, Vachara
    Rozen, Warren Matthew
    Eschen, Gete Ester Toft
    Damsgaard, Tine Engberg
    Kiil, Birgitte Jul
    MICROSURGERY, 2015, 35 (04) : 262 - 271
  • [39] Evaluation of intestinal necrosis with laser Doppler in experimental mesenteric ischemia model
    Aksoy, Nurullah
    Kaplan, Davut Sinan
    Orkmez, Mustafa
    Eronat, Omer
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2024, 30 (01): : 1 - 8
  • [40] Experimental model for the study of soft tissue fixation methods on skin-pericranium flaps in rats
    Cavazana, William Cesar
    Nakamura Cuman, Roberto Kenji
    Takeshita, Wilton Mitsunari
    Passeri, Luis Augusto