Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry

被引:25
作者
Beach, Daniel G. [1 ]
Melanson, Jeremy E. [2 ]
Purves, Randy W. [3 ]
机构
[1] Natl Res Council Canada, Measurement Sci & Stand, Halifax, NS B3H 3Z1, Canada
[2] Natl Res Council Canada, Measurement Sci & Stand, Ottawa, ON K1A 0R6, Canada
[3] Univ Saskatchewan, Dept Plant Sci, Saskatoon, SK S7N 5A8, Canada
关键词
Differential mobility spectrometry (DMS); Paralytic shellfish poisoning (PSP); Algal toxins; Marine biotoxins; Liquid chromatography-mass spectrometry; High-field asymmetric waveform ion mobility spectrometry (FAIMS); QUANTITATIVE-DETERMINATION; LABORATORY VALIDATION; FAIMS; SENSITIVITY; SEPARATION; OYSTERS; MUSSELS;
D O I
10.1007/s00216-015-8488-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of paralytic shellfish toxins (PSTs) by liquid chromatography-mass spectrometry remains a challenge because of their high polarity, large number of analogues and the complex matrix in which they occur. Here we investigate the potential utility of high-field asymmetric waveform ion mobility spectrometry (FAIMS) as a gas-phase ion separation tool for analysis of PSTs by mass spectrometry. We investigate the separation of PSTs using FAIMS with two divergent goals: using FAIMS as a primary separation tool for rapid screening by electrospray ionization (ESI)-FAIMS-MS or combined with LC in a multidimensional LC-ESI-FAIMS-MS separation. First, a survey of the parameters that affect the sensitivity and selectivity of PST analysis by FAIMS was carried out using ESI-FAIMS-MS. In particular, the use of acetonitrile as a gas additive in the carrier gas flow offered good separation of all PST epimeric pairs. A second set of FAIMS conditions was also identified, which focussed PSTs to a relatively narrow CV range allowing development of an LC-ESI-FAIMS-MS method for analysis of PST toxins in complex mussel tissue extracts. The quantitative capabilities of this method were evaluated by analysing a PST containing mussel tissue matrix material. Results compared favourably with analysis by an established LC-post-column oxidation-fluorescence method with recoveries ranging from 70 to 106 %, although sensitivity was somewhat reduced. The current work represents the first successful separation of PST isomers using ion mobility and shows the promise of FAIMS as a tool for analysis of algal biotoxins in complex samples and outlines some critical requirements for its future improvement.
引用
收藏
页码:2473 / 2484
页数:12
相关论文
共 34 条
[11]   Detection of nine chlorinated and brominated haloacetic acids at part-per-trillion levels using ESI-FAIMS-MS [J].
Ells, B ;
Barnett, DA ;
Purves, RW ;
Guevremont, R .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4555-4559
[12]   Comparison of high-field asymmetric waveform ion mobility spectrometry with GC methods in analysis of haloacetic acids in drinking water [J].
Gabryelski, W ;
Wu, FW ;
Froese, KL .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2478-2486
[13]  
Guevremont R, 2006, US Patent, Patent No. [7,026,612, 70266612]
[14]   Extending the Dynamic Range of the Ion Trap by Differential Mobility Filtration [J].
Hall, Adam B. ;
Coy, Stephen L. ;
Kafle, Amol ;
Glick, James ;
Nazarov, Erkinjon ;
Vouros, Paul .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (09) :1428-1436
[15]   Three Rs approaches in marine biotoxin testing - The report and recommendations of a joint ECVAM/DG SANCO workshop (ECVAM workshop 55) [J].
Hess, Philipp ;
Grune, Barbara ;
Anderson, David B. ;
Aune, Tore ;
Botana, Luis M. ;
Caricato, Paolo ;
van Egmond, Hans P. ;
Halder, Marlies ;
Hall, Sherwood ;
Lawrence, James F. ;
Moffat, Colin ;
Poletti, Roberto ;
Richmond, John ;
Rossini, Gian Paolo ;
Seamer, Catherine ;
Vilageliu, Jorge Serratosa .
ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2006, 34 (02) :193-224
[16]  
MBA, 2000, 95908 MBA AOAC INT
[17]  
McNabb P, 2005, J AOAC INT, V88, P761
[18]  
Poyer S, 2014, 62 ASMS C MASS SPECT
[19]   On an Aerodynamic Mechanism to Enhance Ion Transmission and Sensitivity of FAIMS for Nano-Electrospray Ionization-Mass Spectrometry [J].
Prasad, Satendra ;
Belford, Michael W. ;
Dunyach, Jean-Jacques ;
Purves, Randy W. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (12) :2143-2153
[20]   Using Gas Modifiers to Significantly Improve Sensitivity and Selectivity in a Cylindrical FAIMS Device [J].
Purves, Randy W. ;
Ozog, Allison R. ;
Ambrose, Stephen J. ;
Prasad, Satendra ;
Belford, Michael ;
Dunyach, Jean-Jacques .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (07) :1274-1284