Measuring fetal adipose tissue using 3D water-fat magnetic resonance imaging: a feasibility study

被引:11
|
作者
Giza, Stephanie A. [1 ]
Olmstead, Craig [2 ]
McCooeye, Daniel A. [1 ]
Miller, Michael R. [3 ,4 ]
Penava, Deborah A. [2 ,3 ,5 ]
Eastabrook, Genevieve D. [2 ,3 ,5 ]
McKenzie, Charles A. [1 ,3 ]
de Vrijer, Barbra [2 ,3 ,5 ]
机构
[1] Western Univ, Schulich Sch Med & Dent, Dept Med Biophys, London, ON, Canada
[2] Western Univ, Schulich Sch Med & Dent, 800 Commissioners Rd E, London, ON, Canada
[3] Childrens Hlth Res Inst, London, ON, Canada
[4] Western Univ, Schulich Sch Med & Dent, Dept Pediat, London, ON, Canada
[5] Western Univ, Schulich Sch Med & Dent, Dept Obstet & Gynaecol, London, ON, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
Adipose tissue; development; fetus; magnetic resonance imaging; water-fat MRI; SUBCUTANEOUS FAT; BIRTH-WEIGHT; IN-UTERO; GROWTH; PREGNANCIES; PHENOTYPE; THICKNESS; HEALTHY; MRI;
D O I
10.1080/14767058.2018.1506438
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose: Analysis of fetal adipose tissue volumes may provide useful insight towards assessment of overall fetal health, especially in cases with abnormal fetal growth. Here, we assess whether fetal adipose tissue volume can be reliably measured using 3D water-fat MRI, using a quantitative assessment of the lipid content of tissues. Materials and methods: Seventeen women with singleton pregnancies underwent a fetal MRI and water-only and fat-only images were acquired (modified 2-point Dixon technique). Water and fat images were used to generate a fat signal fraction (fat/(water + fat)) from which subcutaneous adipose tissue was segmented along the fetal trunk. Inter-rater (three readers) and intrarater reliability was assessed using intraclass-correlation coefficients (ICC) for 10 image sets. Relationships between adipose tissue measurements and gestational age and estimated fetal weight percentiles were examined. Results: The ICC of the inter-rater reliability was 0.936 (p < .001), and the ICC of the intrarater reliability was 0.992 (p < .001). Strong positive correlations were found between adipose tissue measurements (lipid volume, lipid volume/total fetal volume, mean fat signal fraction) and gestational age. Conclusions: 3D water-fat MRI can reliably measure volume and quantify lipid content of fetal subcutaneous adipose tissues.
引用
收藏
页码:831 / 837
页数:7
相关论文
共 50 条
  • [41] Brain Tumor Segmentation Using 3D Magnetic Resonance Imaging Scans
    Junejo, Aisha Zahid
    Memon, Sheeraz A.
    Memon, Isha Zameer
    Talpur, Shahnawaz
    2018 1ST INTERNATIONAL CONFERENCE ON ADVANCED RESEARCH IN ENGINEERING SCIENCES (ARES), 2018,
  • [42] Magnetic resonance imaging in fetal anomalies: What does it add to 3D and 4D US?
    Behairy, Noha H.
    Talaat, Soha
    Saleem, Sahar N.
    Abd El-Raouf, Maged
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (01) : 250 - 255
  • [43] Intrahepatic fat, abdominal adipose tissues, and metabolic state: magnetic resonance imaging study
    Meir, Anat Yaskolka
    Tene, Lilac
    Cohen, Noa
    Shelef, Ilan
    Schwarzfuchs, Dan
    Gepner, Yftach
    Zelicha, Hila
    Rein, Michal
    Bril, Nitzan
    Serfaty, Dana
    Kenigsbuch, Shira
    Chassidim, Yoash
    Sarusy, Benjamin
    Dicker, Dror
    Thiery, Joachim
    Ceglarek, Uta
    Stumvoll, Michael
    Blueher, Matthias
    Stampfer, Meir J.
    Rudich, Assaf
    Shai, Iris
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2017, 33 (05)
  • [44] Study of the development of fetal baboon brain using magnetic resonance imaging at 3 Tesla
    Liu, Feng
    Garland, Manianne
    Duan, Yunsuo
    Stark, Raymond I.
    Xu, Dongrong
    Dong, Zhengchao
    Barisal, Ravi
    Peterson, Bradley S.
    Kangarlu, Alayar
    NEUROIMAGE, 2008, 40 (01) : 148 - 159
  • [45] Optimization of the image contrast for the developing fetal brain using 3D radial VIBE sequence in 3 T magnetic resonance imaging
    Liao, Yi
    Li, Xuesheng
    Jia, Fenglin
    Ye, Zhijun
    Ning, Gang
    Liu, Sai
    Li, Pei
    Fu, Chuan
    Li, Qing
    Wang, Shaoyu
    Zhang, Huapeng
    Qu, Haibo
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [46] Optimization of the image contrast for the developing fetal brain using 3D radial VIBE sequence in 3 T magnetic resonance imaging
    Yi Liao
    Xuesheng Li
    Fenglin Jia
    Zhijun Ye
    Gang Ning
    Sai Liu
    Pei Li
    Chuan Fu
    Qing Li
    Shaoyu Wang
    Huapeng Zhang
    Haibo Qu
    BMC Medical Imaging, 22
  • [47] Measuring water distribution in extrudates using magnetic resonance imaging (MRI)
    Tomer, G
    Mantle, MD
    Gladden, LF
    Newton, JM
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1999, 189 (01) : 19 - 28
  • [48] Exploring Adipose Tissue Structure by Methylsalicylate Clearing and 3D Imaging
    Gilleron, Jerome
    Meziat, Cindy
    Sulen, Andre
    Ivanov, Stoyan
    Jager, Jennifer
    Esteve, David
    Muller, Catherine
    Tanti, Jean-Francois
    Cormont, Mireille
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (162): : 1 - 16
  • [49] Application of a fuzzy inference system to the quantification of 3D magnetic resonance imaging of breast tissue
    Carballido-Gamio, J
    Klifa, C
    Majumdar, S
    Hylton, N
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1539 - 1547
  • [50] Brown adipose tissue estimated with the magnetic resonance imaging fat fraction is associated with glucose metabolism in adolescents
    Lundstrom, Elin
    Ljungberg, Joy
    Andersson, Jonathan
    Manell, Hannes
    Strand, Robin
    Forslund, Anders
    Bergsten, Peter
    Weghuber, Daniel
    Morwald, Katharina
    Zsoldos, Fanni
    Widhalm, Kurt
    Meissnitzer, Matthias
    Ahlstrom, Hakan
    Kullberg, Joel
    PEDIATRIC OBESITY, 2019, 14 (09):