Programmable Analytical Feature of Ratiometric Electrochemical Biosensor by Alternating the Binding Site of Ferrocene to DNA Duplex for the Detection of Aflatoxin B1†

被引:8
|
作者
Liu, Dong [1 ]
Jia, Fan [1 ]
Wei, Ya [1 ]
Li, Yuye [1 ]
Meng, Shuyun [1 ]
You, Tianyan [1 ]
机构
[1] Jiangsu Univ, Sch Agr Engn, Key Lab Modern Agr Equipment & Technol, Minist Educ, Zhenjiang 212013, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemistry; Biosensors; Aptamers; Ratiometric detection; Aflatoxins; APTASENSOR; SENSORS;
D O I
10.1002/cjoc.202200155
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Comprehensive Summary Ratiometric biosensor is among the promising strategies for the advanced analysis; its applicability in multiple scenarios, however, is seriously limited for the fixed analytical feature. Here, we reported ratiometric electrochemical biosensors with programmable analytical feature by alternating the binding site of ferrocene (Fc) to DNA duplex for the detection of aflatoxin B1 (AFB1). DNA duplex was synthesized with AFB1 aptamer and its complementary DNA (cDNA) with Fc molecular tagged on aptamer or cDNA. For analysis, aptamer-AFB1 complex stripped from the electrode, and free cDNA triggered hybridization chain reaction to produce double-stranded DNA for methylene blue (MB) absorption. In this way, redox currents of Fc (I-Fc) and absorbed MB (I-MB) at the electrode were collected to produce the ratiometric signal of I-MB/I-Fc as a yardstick for AFB1. When Fc was tagged on aptamer, I-Fc decreased with higher concentration of AFB1 (c(AFB1)), the resultant biosensor allowed detection with an On/Off (I-MB/I-Fc) mode; when Fc was tagged on cDNA, I-Fc kept constant as c(AFB1) varying, offering an On/Constant (I-MB/I-Fc) mode for the detection. Consequently, biosensor with On/Off mode showed a linear range of 0.1-100 pg/mL with a limit of detection (LOD) of 0.0650 pg/mL, while biosensor with On/Constant mode offered a wider linear rang of 1-10000 pg/mL but a relatively poor LOD of 0.330 pg/mL. Our work revealed the vital importance of binding site of probes to DNA, and this principle can endow ratiometric biosensor with programmable analytical feature (e.g., linear range, LOD), allowing detections in various scenarios.
引用
收藏
页码:2232 / 2238
页数:7
相关论文
共 50 条
  • [1] Sensitivity programmable ratiometric electrochemical aptasensor based on signal engineering for the detection of aflatoxin B1 in peanut
    Li, Yuye
    Liu, Dong
    Zhu, Chengxi
    Shen, Xiuli
    Liu, Yang
    You, Tianyan
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 387
  • [2] DNAzyme-driven tripedal DNA walker for ratiometric electrochemical aptasensor ultrasensitive detection of aflatoxin B1
    Liang, Jiong
    Zhang, Yunzhe
    Li, Zikun
    Lu, Xin
    Qi, Congyan
    Yang, Qian
    Zhang, Wei
    FOOD CONTROL, 2024, 164
  • [3] Gold nanobipyramids integrated ultrasensitive optical and electrochemical biosensor for Aflatoxin B1 detection
    Bhardwaj, Hema
    Sumana, Gajjala
    Marquette, Christophe A.
    TALANTA, 2021, 222
  • [4] Dual-ratiometric electrochemical aptasensor enabled by programmable dynamic range: Application for threshold-based detection of aflatoxin B1
    Li, Yuye
    Liu, Dong
    Meng, Shuyun
    Chen, Ting
    Liu, Chang
    You, Tianyan
    BIOSENSORS & BIOELECTRONICS, 2022, 195
  • [5] DNA tetrahedral scaffold based one-step ratiometric electrochemical detection of aflatoxin B1 in tobacco samples
    He, Fan
    Jiao, Shaohe
    Zou, Rongxing
    Lai, Miao
    Zhao, Mingqin
    Wang, Nianlei
    Zhang, Hong
    MICROCHEMICAL JOURNAL, 2024, 207
  • [6] Gold nanobipyramids integrated ultrasensitive optical and electrochemical biosensor for Aflatoxin B1 detection
    Bhardwaj, Hema
    Sumana, Gajjala
    Marquette, Christophe A.
    Talanta, 2022, 222
  • [7] Thermal stabilization of the DNA duplex by adducts of aflatoxin B1
    Giri, I
    Stone, MP
    BIOPOLYMERS, 2002, 65 (03) : 190 - 201
  • [8] An electrochemical biosensor for the detection of aflatoxin B1 based on the specific aptamer and HCR biological magnification
    Zhang, Hongyan
    Ye, Siying
    Huang, Lishan
    Fan, Shen
    Mao, Weiwei
    Hu, Yijin
    Yu, Yuyan
    Fu, Fengfu
    ANALYTICAL METHODS, 2022, 15 (01) : 99 - 108
  • [9] Preparation of a biosensor for DNA damage detection and its application in rapid detection of aflatoxin B1 in feed
    Fang, Jun-Jie
    Sun, Yu-Xue
    Ye, Yong-Kang
    Sun, Han-Ju
    Modern Food Science and Technology, 2014, 30 (08) : 270 - 275
  • [10] A reusable ratiometric electrochemical biosensor on the basis of the binding of methylene blue to DNA with alternating AT base sequence for sensitive detection of adenosine
    Cui, Lin
    Lu, Mengfei
    Li, Ying
    Tang, Bo
    Zhang, Chun-yang
    BIOSENSORS & BIOELECTRONICS, 2018, 102 : 87 - 93