Multiscale Poincare plot analysis of time series from laser speckle contrast imaging data

被引:4
|
作者
Humeau-Heurtier, Anne [1 ]
Mahe, Guillaume [2 ]
Hunault, Gilles [3 ]
Gascoin, Lydie [4 ]
Abraham, Pierre [5 ]
机构
[1] Univ Angers, LARIS, 62 Ave Notre Dame du Lac, F-49000 Angers, France
[2] Univ Rennes 1, Rennes Pontchaillou Hosp, Pole Imagerie Med & Explorat Fonct, Inserm CIC 1414, Rennes, France
[3] Univ Angers, HIFIH Lab Hemodynam Interact Fibrose & Invasivite, Angers, France
[4] Univ Angers, Angers Hosp, Lab Physiol & Explorat Vasc, Angers, France
[5] Univ Angers, Angers Hosp, Lab Physiol & Explorat Vasc, UMR CNRS 6214,INSERM 1083, Angers, France
关键词
Complexity; Nonlinear dynamics; Multiscale; Laser speckle contrast imaging; Poincare plot; AGE-RELATED-CHANGES; BLOOD-FLOW; ENDOTHELIAL FUNCTION; DOPPLER; FLOWMETRY; ENTROPY; MICROCIRCULATION; REPRODUCIBILITY; OSCILLATIONS; VARIABILITY;
D O I
10.1016/j.bspc.2017.07.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The monitoring of microvascular blood flow is of importance for research and clinical purposes because, for some pathologies as diabetes, the microcirculation may be affected long before organ dysfunctions are diagnosed. Laser speckle contrast imaging (LSCI) is gaining an increased interest to monitor microvascular blood flow (peripheral cardiovascular data). However, in spite of this and by opposition to central cardiovascular data as electrocardiograms, very few studies have been conducted on the analysis of LSCI through scales. We therefore propose to process LSCI data with a multiscale approach relying on Poincare plots. For this purpose, we first study multiscale Poincare (MSP) plots of simulated signals (synthetic white and 1/f noise time series). Then, MSP plots of LSCI time series recorded in 24 healthy volunteers are generated and analyzed. Furthermore, this analysis on real-life data is also conducted to study the role played by age on the results. Thus, the subjects were divided into two age groups: 13 young subjects (mean age = 23.8 +/- 3.2 years old) and 11 elderly subjects (mean age=56.94 +/- 6.7 years old). Our results show properties that may reveal a weak fractal structure for LSCI data. Moreover, we find no statistical difference (p >= 0.05) for the descriptors of MSP plots between the two age groups. MSP plots may become a simple-to-implement visualization tool to provide new insights into biomedical data across scales. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:361 / 369
页数:9
相关论文
共 50 条
  • [21] Wavelet Analysis of the Temporal Dynamics of the Laser Speckle Contrast in Human Skin
    Mizeva, Irina
    Dremin, Viktor
    Potapova, Elena
    Zherebtsov, Evgeny
    Kozlov, Igor
    Dunaev, Andrey
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (07) : 1882 - 1889
  • [22] Impact of light polarization on laser speckle contrast imaging with a custom phantom for microvascular flow
    Amini, Nasrin
    Esteki, Ali
    Ahmadi, Mohsen
    Sasanpour, Pezhman
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] Comparison of laser speckle contrast imaging with laser Doppler perfusion imaging for tissue perfusion measurement
    Guven, Goksel
    Dijkstra, Annemieke
    Kuijper, Tjallingius Martijn
    Trommel, Nicole
    van Baar, Margriet Elisabeth
    Topeli, Arzu
    Ince, Can
    van der Vlies, Cornelis Hendrik
    MICROCIRCULATION, 2023, 30 (01)
  • [24] Improving Contrast Accuracy and Resolution of Laser Speckle Contrast Imaging Using Two-Dimensional Entropy Algorithm
    Liu, Xinglong
    Yang, Hui
    Li, Ran
    IEEE ACCESS, 2021, 9 : 148925 - 148932
  • [25] Effect of static scatterers in laser speckle contrast imaging: an experimental study on correlation and contrast
    Vaz, Pedro G.
    Humeau-Heurtier, Anne
    Figueiras, Edite
    Correia, Carlos
    Cardoso, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01)
  • [26] Analysis of Critically Perfused Tissues by Laser Speckle Contrast Analysis (LASCA) Perfusion Imaging
    Limbourg, A.
    Radtke, C.
    Ipaktchi, R.
    Vogt, P. M.
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2016, 48 (06) : 354 - 362
  • [27] Laser Speckle Contrast Imaging for Monitoring Changes in Microvascular Blood Flow
    Ambrus, Rikard
    Strandby, Rune B.
    Svendsen, Lars Bo
    Achiam, Michael P.
    Steffensen, John F.
    Svendsen, Morten Bo Sondergaard
    EUROPEAN SURGICAL RESEARCH, 2016, 56 (3-4) : 87 - 96
  • [28] Skin perfusion evaluation between laser speckle contrast imaging and laser Doppler flowmetry
    Humeau-Heurtier, Anne
    Mahe, Guillaume
    Durand, Sylvain
    Abraham, Pierre
    OPTICS COMMUNICATIONS, 2013, 291 : 482 - 487
  • [29] The Applicability of the Poincare Plot in the Analysis of Variability of Reaction Time during Serial Testing
    Iconaru, Elena Ioana
    Ciucurel, Manuela Mihaela
    Georgescu, Luminita
    Tudor, Mariana
    Ciucurel, Constantin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (07)
  • [30] Multiscale recurrence plot and recurrence quantification analysis for financial time series
    Yin, Yi
    Shang, Pengjian
    NONLINEAR DYNAMICS, 2016, 85 (04) : 2309 - 2352