Optoelectronic iron detectors for pharmaceutical flow analysis

被引:9
作者
Rybkowska, Natalia [1 ]
Koncki, Robert [1 ]
Strzelak, Kamil [1 ]
机构
[1] Univ Warsaw, Dept Chem, Pasteura 1, PL-02093 Warsaw, Poland
关键词
Iron determination; Supplements; Optoelectronic detector; Flow analysis; PHOTOMETRY; SYSTEM; DIODES;
D O I
10.1016/j.jpba.2017.06.057
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Compact flow-through optoelectronic detectors fabricated by pairing of light emitting diodes have been applied for development of economic flow analysis systems dedicated for iron ions determination. Three analytical methods with different chromogens selectively recognizing iron ions have been compared. Ferrozine and ferene S based methods offer higher sensitivity and slightly lower detection limits than method with 1,10-phenantroline, but narrower ranges of linear response. Each system allows detection of iron in micromolar range of concentration with comparable sample throughput (20 injections per hour). The developed flow analysis systems have been successfully applied for determination of iron in diet supplements. The utility of developed analytical systems for iron release studies from drug formulations has also been demonstrated. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:504 / 508
页数:5
相关论文
共 24 条
  • [1] Beard JL, 1996, NUTR REV, V54, P295, DOI 10.1111/j.1753-4887.1996.tb03794.x
  • [2] Burtis CA., 2006, TIETZ TXB CLIN CHEM, V4th
  • [3] A flow cell with a new design to improve the utilization of the radiation emitted by LED and employed as a radiation source for photometric detection
    Dias, Tuanne R.
    Brasil, Marcos A. S.
    Feres, Mario A.
    Reis, Boaventura F.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 448 - 454
  • [4] Pulsed flows in flow analysis: Potentialities, limitations and applications
    Gonzalez, Pablo
    Knochen, Moises
    Sasaki, Milton K.
    Zagatto, Elias A. G.
    [J]. TALANTA, 2015, 143 : 419 - 430
  • [5] FERENE - A NEW SPECTROPHOTOMETRIC REAGENT FOR IRON
    HENNESSY, DJ
    REID, GR
    SMITH, FE
    THOMPSON, SL
    [J]. CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1984, 62 (04): : 721 - 724
  • [6] Double-beam photometric direct-injection detector for multi-pumping flow system
    Kalinowski, Slawomir
    Koronkiewicz, Stanislawa
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2017, 258 : 146 - 155
  • [7] Application of direct-injection detector integrated with the multi-pumping flow system to photometric stop-flow determination of total iron
    Koronkiewicz, Stanislawa
    Kalinowski, Slawomir
    [J]. TALANTA, 2012, 96 : 68 - 74
  • [8] A novel direct-injection photometric detector integrated with solenoid pulse-pump flow system
    Koronkiewicz, Stanislawa
    Kalinowski, Slawomir
    [J]. TALANTA, 2011, 86 : 436 - 441
  • [9] Krawczyk M., 2013, J PHARM BIOMED ANAL, V88, P377
  • [10] Multicommutation in Flow Systems: A Useful Tool for Pharmaceutical and Clinical Analysis
    Llorent-Martinez, Eulogio J.
    Barrales, Pilar O.
    Luisa Fernandez-de Cordova, M.
    Ruiz-Medina, Antonio
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2010, 6 (01) : 53 - 65