Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy

被引:23
作者
Mustari, Afrina [1 ]
Nishidate, Izumi [1 ]
Wares, Md Abdul [1 ,6 ]
Maeda, Takaaki [2 ]
Kawauchi, Satoko [3 ]
Sato, Shunichi [3 ]
Sato, Manabu [4 ]
Aizu, Yoshihisa [5 ]
机构
[1] Tokyo Univ Agr & Technol, Grad Sch Bioapplicat & Syst Engn, Tokyo, Japan
[2] Kushiro Natl Coll Technol, Dept Mech Engn, Kushiro, Hokkaido, Japan
[3] Natl Def Med Coll, Res Inst, Div Bioinformat & Therapeut Syst, Tokorozawa, Saitama, Japan
[4] Yamagata Univ, Grad Sch Sci & Engn, Yamagata, Japan
[5] Muroran Inst Technol, Coll Design & Mfg Technol, Muroran, Hokkaido, Japan
[6] Govt Bangladesh, Minist Fisheries & Livestock, Dept Livestock Serv, Dhaka, Bangladesh
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2018年 / 138期
关键词
Bioengineering; Issue; 138; Optical phantom; agarose gel; lipid emulsion; optical properties; hemoglobin; light scattering; light absorption; inverse Monte Carlo simulation; diffuse reflectance spectroscopy; NEAR-INFRARED SPECTROSCOPY; TURBID MEDIA; SCATTERING; LIGHT; ABSORPTION; CONTRAST; COEFFICIENT;
D O I
10.3791/57578
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This protocol describes how to make agarose-based tissue-mimicking phantoms and demonstrates how to determine their optical properties using a conventional optical system with an integrating sphere. Measuring systems for the acquisition of the diffuse reflectance and total transmittance spectra are constructed with a broadband white light source, a light guide, an achromatic lens, an integrating sphere, a sample holder, an optical fiber probe, and a multi-channel spectrometer. An acrylic mold consisting of two rectangular acrylic pieces and a U-shaped acrylic piece is constructed to create an epidermal phantom and a dermal phantom with whole blood. The application of a sodium dithionite (Na2S2O4) solution to the dermal phantom enables the researcher to deoxygenate hemoglobin in red blood cells distributed in the dermal phantom. The inverse Monte Carlo simulation with the diffuse reflectance and total transmittance spectra measured by a spectrometer with an integrating sphere is performed to determine the absorption coefficient spectrum mu(a)(lambda) and the reduced scattering coefficient spectrum mu(a)'(lambda) of each layer phantom. A two-layered phantom mimicking the diffuse reflectance of human skin tissue is also demonstrated by piling up the epidermal phantom on the dermal phantom.
引用
收藏
页数:10
相关论文
共 45 条
[1]  
Bays R, 1997, LASER SURG MED, V21, P227, DOI 10.1002/(SICI)1096-9101(1997)21:3<227::AID-LSM2>3.0.CO
[2]  
2-S
[3]   Correlation properties of multiple scattered light: implication to coherent diagnostics of burned skin [J].
Bednov, A ;
Ulyanov, S ;
Cheung, C ;
Yodh, AG .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (02) :347-352
[4]   Stable phantom materials for ultrasound and optical imaging [J].
Cabrelli, Luciana C. ;
Pelissari, Pedro I. B. G. B. ;
Deana, Alessandro M. ;
Carneiro, Antonio A. O. ;
Pavan, Theo Z. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02) :432-447
[5]   CONTRAST-DETAIL-DOSE ANALYSIS OF 6 DIFFERENT COMPUTED TOMOGRAPHIC SCANNERS [J].
COHEN, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (02) :197-203
[6]   A solid tissue phantom for photon migration studies [J].
Cubeddu, R ;
Pifferi, A ;
Taroni, P ;
Torricelli, A ;
Valentini, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (10) :1971-1979
[7]   Tissue-Mimicking Gel Phantoms for Thermal Therapy Studies [J].
Dabbagh, Ali ;
Abdullah, Basri Johan Jeet ;
Ramasindarum, Chanthiriga ;
Abu Kasim, Noor Hayaty .
ULTRASONIC IMAGING, 2014, 36 (04) :291-316
[8]   OPTICALLY DILUTE, ABSORBING, AND TURBID PHANTOMS FOR FLUORESCENCE SPECTROSCOPY OF HOMOGENEOUS AND INHOMOGENEOUS SAMPLES [J].
DURKIN, AJ ;
JAIKUMAR, S ;
RICHARDSKORTUM, R .
APPLIED SPECTROSCOPY, 1993, 47 (12) :2114-2121
[9]   Near-infrared fluorescent dyes for enhanced contrast in optical mammography: phantom experiments [J].
Ebert, B ;
Sukowski, U ;
Grosenick, D ;
Wabnitz, H ;
Moesta, TK ;
Licha, K ;
Becker, A ;
Semmler, W ;
Schlag, PM ;
Rinneberg, H .
JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (02) :134-140
[10]   A PHANTOM FOR THE TESTING AND CALIBRATION OF NEAR-INFRARED SPECTROMETERS [J].
FIRBANK, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09) :1509-1513