Determining the radon exhalation rate from a gold mine tailings dump by measuring the gamma radiation

被引:14
作者
Ongori, Joash N. [1 ]
Lindsay, Robert [1 ]
Newman, Richard T. [2 ]
Maleka, Peane P. [3 ]
机构
[1] Univ Western Cape, Dept Phys, ZA-7535 Bellville, South Africa
[2] Univ Stellenbosch, Dept Phys, ZA-7602 Stellenbosch, South Africa
[3] iThemba Lab Accelerator Based Sci LABS, Dept Nucl Phys, ZA-7129 Somerset West, South Africa
关键词
Radon; Radon exhalation; Gamma-ray spectrometry; Gold mine tailings; South Africa; RN-222; EXHALATION; DIFFUSIVE TRANSPORT; SOUTH-AFRICA; FLUX; SOIL; HOUSES; SIMULATION; MONITORS; DENSITY; SURFACE;
D O I
10.1016/j.jenvrad.2014.10.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The mining activities taking place in Gauteng province, South Africa have caused millions of tons of rocks to be taken from underground to be milled and processed to extract gold. The uranium bearing tailings are placed in an estimated 250 dumps covering a total area of about 7000 ha. These tailings dumps contain considerable amounts of radium and have therefore been identified as large sources of radon. The size of these dumps make traditional radon exhalation measurements time consuming and it is difficult to get representative measurements for the whole dump. In this work radon exhalation measurements from the non-operational Kloof mine dump have been performed by measuring the gamma radiation from the dump fairly accurately over an area of more than 1 km(2). Radon exhalation from the mine dump have been inferred from this by laboratory-based and insitu gamma measurements. Thirty four soil samples were collected at depths of 30 cm and 50 cm. The weighted average activity concentrations in the soil samples were 308 +/- 7 Bq kg(-1), 255 +/- 5 Bq kg(-1) and 18 +/- 1 Bq kg(-1) for U-238, K-40 and Th-232, respectively. The MEDUSA (Multi-Element Detector for Underwater Sediment Activity) gamma-ray detection system was used for field measurements. The radium concentrations were then used with soil parameters to obtain the radon flux using different approaches such as the IAEA (International Atomic Energy Agency) formula. Another technique the MEDUSA Laboratory Technique (MELT) was developed to map radon exhalation based on (1) recognising that radon exhalation does not affect K-40 and Th-232 activity concentrations and (2) that the ratio of the activity concentration of the field (MEDUSA) to the laboratory (HPGe) for U-238 and K-40 or U-238 and Th-232 will give a measure of the radon exhalation at a particular location in the dump. The average, normalised radon flux was found to be 0.12 +/- 0.02 Bq m(-2) s(-1) for the mine dump. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 77 条
  • [1] AKERBLOM G., 1997, Radon measurements by eatched track detectors. Applications in radiation Protection, P21
  • [2] ALDENKAMP FJ, 1992, RADIAT PROT DOSIM, V45, P449
  • [3] Numerical modelling of radon-222 entry into houses: an outline of techniques and results
    Andersen, CE
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 272 (1-3) : 33 - 42
  • [4] [Anonymous], SURFER8 US GUID CONT
  • [5] [Anonymous], INT RAD S
  • [6] [Anonymous], INT RAD S 2
  • [7] [Anonymous], NAT RAD ENV 8 INT S
  • [8] [Anonymous], 1982, ION RAD SOURC BIOL E
  • [9] [Anonymous], HLTH EFF EXP RAD BEI
  • [10] [Anonymous], REF MAN VERS 6 0 1 R