Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall

被引:3
作者
Ortilles, A. [1 ,2 ]
Pascual, G. [3 ,4 ]
Pena, E. [1 ,4 ]
Rodriguez, M. [4 ,5 ]
Perez-Kohler, B. [4 ,5 ]
Mesa-Ciller, C. [4 ,5 ]
Calvo, B. [1 ,4 ]
Bellon, J. M. [4 ,5 ]
机构
[1] Univ Zaragoza, Aragon Inst Engn Res I3A, Zaragoza, Spain
[2] Univ Zaragoza, Dept Anim Pathol, Zaragoza, Spain
[3] Univ Alcala, Fac Med & Hlth Sci, Dept Med & Med Special, Alcala De Henares, Spain
[4] Ctr Invest Biomed Red Bioingn Biomat & Nanomed CI, Zaragoza, Spain
[5] Univ Alcala, Fac Med & Hlth Sci, Dept Surg Med & Social Sci, Alcala De Henares, Spain
关键词
Mesh fixation; Cyanoacrylate glue; Suture; High-density polypropylene meshes; Hernia; INGUINAL-HERNIA REPAIR; FIBRIN-SEALANT; LICHTENSTEIN TECHNIQUE; SUTURE; TRIAL; EFFICIENCY; ADHESIVES; PAIN;
D O I
10.1016/j.jmbbm.2017.08.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex viva and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops.
引用
收藏
页码:434 / 441
页数:8
相关论文
共 25 条
  • [1] Tuning adhesion failure strength for tissue-specific applications
    Artzi, Natalie
    Zeiger, Adam
    Boehning, Fiete
    bon Ramos, Adriana
    van Vliet, Krystyn
    Edelman, Elazer R.
    [J]. ACTA BIOMATERIALIA, 2011, 7 (01) : 67 - 74
  • [2] Behavior of a new long-chain cyanoacrylate tissue adhesive used for mesh fixation in hernia repair
    Bellon, Juan M.
    Fernandez-Gutierrez, Mar
    Rodriguez, Marta
    Perez-Lopez, Paloma
    Perez-Kohler, Barbara
    Kuhnhardt, Andree
    Pascual, Gemma
    San Roman, Julio
    [J]. JOURNAL OF SURGICAL RESEARCH, 2017, 208 : 68 - 83
  • [3] Transporous hernia mesh fixation with fibrin sealant in an in vitro model of spray application
    Brand, Julian
    Gruber-Blum, Simone
    Gruber, Kerstin
    Fortelny, Rene H.
    Redl, Heinz
    Petter-Puchner, Alexander H.
    [J]. JOURNAL OF SURGICAL RESEARCH, 2013, 183 (02) : 726 - 732
  • [4] Objective hypoesthesia and pain after transabdominal preperitoneal hernioplasty: a prospective, randomized study comparing tissue adhesive versus spiral tacks
    Bruegger, Lukas
    Bloesch, Martina
    Ipaktchi, Ramin
    Kurmann, Anita
    Candinas, Daniel
    Beldi, Guido
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (04): : 1079 - 1085
  • [5] Randomized, controlled, blinded trial of Tissucol/Tisseel for mesh fixation in patients undergoing Lichtenstein technique for primary inguinal hernia repair: rationale and study design of the TIMELI trial
    Campanelli, G.
    Champault, G.
    Pascual, M. Hidalgo
    Hoeferlin, A.
    Kingsnorth, A.
    Rosenberg, J.
    Miserez, M.
    [J]. HERNIA, 2008, 12 (02) : 159 - 165
  • [6] Meta-analysis of glue versus sutured mesh fixation for Lichtenstein inguinal hernia repair
    de Goede, B.
    Klitsie, P. J.
    van Kempen, B. J. H.
    Timmermans, L.
    Jeekel, J.
    Kazemier, G.
    Lange, J. F.
    [J]. BRITISH JOURNAL OF SURGERY, 2013, 100 (06) : 735 - 742
  • [7] Laparoscopic spray application of fibrin sealant effects on hemodynamics and spray efficiency at various application pressures and distances
    Druckrey-Fiskaaen, K. T.
    Janssen, M. W. W.
    Omidi, L.
    Polze, N.
    Kaisers, U.
    Nur, I.
    Goldberg, E.
    Bokel, G.
    Hauss, J.
    Schoen, Michael R.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2007, 21 (10): : 1750 - 1759
  • [8] Structural Analysis and Application of n-Alkyl Cyanoacrylate Surgical Adhesives to the Fixation of Meshes for Hernia Repair
    Fernandez-Gutierrez, Mar
    Rodriguez-Mancheno, Marta
    Perez-Kohler, Barbara
    Pascual, Gemma
    Manuel Bellon, Juan
    San Roman, Julio
    [J]. MACROMOLECULAR BIOSCIENCE, 2016, 16 (12) : 1803 - 1814
  • [9] Assessment of pain and quality of life in Lichtenstein hernia repair using a new monofilament PTFE mesh: comparison of suture vs. fibrin-sealant mesh fixation
    Forteiny, Rene H.
    Petter-Puchner, Alexander H.
    Redi, Heinz
    May, Christopher
    Pospischil, Wolfgang
    Glaser, Karl
    [J]. FRONTIERS IN SURGERY, 2014, 1
  • [10] Long-term anisotropic mechanical response of surgical meshes used to repair abdominal wall defects
    Hernandez-Gascon, B.
    Pena, E.
    Pascual, G.
    Rodriguez, M.
    Bellon, J. M.
    Calvo, B.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 5 (01) : 257 - 271