Imaging of triglycerides in tissues using nanospray desorption electrospray ionization (Nano-DESI) mass spectrometry

被引:26
作者
Unsihuay, Daisy [1 ]
Qiu, Jiamin [2 ]
Swaroop, Sneha [1 ]
Nagornov, Konstantin O. [3 ]
Kozhinov, Anton N. [3 ]
Tsybin, Yury O. [3 ]
Kuang, Shihuan [2 ]
Laskin, Julia [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Anim Sci, W Lafayette, IN 47907 USA
[3] Spectroswiss EPFL, Innovat Pk 1015, CH-1015 Lausanne, Switzerland
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
EXTRACTION; LIPIDOMICS; MIXTURES;
D O I
10.1016/j.ijms.2019.116269
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Nonpolar triglycerides (TGs) are rarely detected in mass spectrometry imaging (MSI) experiments unless they are abundant in the sample. Herein, we use nanospray desorption electrospray ionization (nano-DESI) to explore the role of the solvent composition and ionic dopants on the detection of TGs in a murine gastrocnemius muscle tissue used as a model system. We evaluated three solvent mixtures for their ability to extract nonpolar TG species: MeOH:H2O 9:1 (v/v), MeOH:DCM 6:4 (v/v) and MeO-H:AcN:tol 5:3.5:1.5 (v/v/v). We observe that TGs are mainly detected as [M+K](+) adducts and their extraction efficiency is improved using less polar solvents: MeOH:DCM and MeOH:AcN:tol. We also explore whether the ionization efficiency of TGs may be improved by doping the MeOH:AcN:tol solvent with ammonium formate (AF) and other ionic additives. However, the formation of [M+NH4](+) adducts of TGs is less efficient than that of [M+K](+) adducts in the range of AF concentrations from 0.1 to 10 mM. Chemical derivatization using 100 mu M of Girard T reagent predominately generates reaction products of phosphatidylcholines rather than TG species. Moreover, the presence of the Girard T reagent suppresses ion signals of all the species in the spectrum including TGs. Nano-DESI MSI experiments performed using MeOH:AcN:tol solvent enable imaging of TGs without any detectable adverse effect on signals of other lipids and metabolites. Specifically, 10 out of 14 TG species were detected exclusively using MeOH:AcN:tol and the sensitivity towards other TGs was improved by at least an order of magnitude. Although polyunsaturated TGs can be detected using both solvents, saturated and monounsaturated TGs are only detected using MeOH:AcN:tol. Our results provide a direct path for the improved detection of TGs in tissue imaging experiments using liquid-based ambient ionization techniques. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Metabolite aberrations in early diabetes detected in rat kidney using mass spectrometry imaging
    Bergman, Hilde-Marlene
    Lindfors, Lina
    Palm, Fredrik
    Kihlberg, Jan
    Lanekoff, Ingela
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (13) : 2809 - 2816
  • [2] MALDI Imaging of Lipid Biochemistry in Tissues by Mass Spectrometry
    Berry, Karin A. Zemski
    Hankin, Joseph A.
    Barkley, Robert M.
    Spraggins, Jeffrey M.
    Caprioli, Richard M.
    Murphy, Robert C.
    [J]. CHEMICAL REVIEWS, 2011, 111 (10) : 6491 - 6512
  • [3] Toward Merging Untargeted and Targeted Methods in Mass Spectrometry-Based Metabolomics and Lipidomics
    Cajka, Tomas
    Fiehn, Oliver
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (01) : 524 - 545
  • [4] Practical implications of some recent studies in electrospray ionization fundamentals
    Cech, NB
    Enke, CG
    [J]. MASS SPECTROMETRY REVIEWS, 2001, 20 (06) : 362 - 387
  • [5] Dichloromethane as a solvent for lipid extraction and assessment of lipid classes and fatty acids from samples of different natures
    Cequier-Sanchez, Elena
    Rodriguez, Covadonga
    Ravelo, Angel G.
    Zarate, Rafael
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (12) : 4297 - 4303
  • [6] Cross-Platform Comparison of Untargeted and Targeted Lipidomics Approaches on Aging Mouse Plasma
    Contrepois, Kevin
    Mahmoudi, Salah
    Ubhi, Baljit K.
    Papsdorf, Katharina
    Hornburg, Daniel
    Brunet, Anne
    Snyder, Michael
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [7] MALDI imaging mass spectrometry: molecular snapshots of biochemical systems
    Cornett, Dale S.
    Reyzer, Michelle L.
    Chaurand, Pierre
    Caprioli, Richard M.
    [J]. NATURE METHODS, 2007, 4 (10) : 828 - 833
  • [8] ELECTROSPRAY AND TANDEM MASS-SPECTROMETRIC CHARACTERIZATION OF ACYLGLYCEROL MIXTURES THAT ARE DISSOLVED IN NONPOLAR-SOLVENTS
    DUFFIN, KL
    HENION, JD
    SHIEH, JJ
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1781 - 1788
  • [9] Quantitative Mass Spectrometry Imaging of Prostaglandins as Silver Ion Adducts with Nanospray Desorption Electrospray Ionization
    Duncan, Kyle D.
    Fang, Ru
    Yuan, Jia
    Chu, Rosalie K.
    Dey, Sudhansu K.
    Burnum-Johnson, Kristin E.
    Lanekoff, Ingela
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (12) : 7246 - 7252
  • [10] Classifying Human Brain Tumors by Lipid Imaging with Mass Spectrometry
    Eberlin, Livia S.
    Norton, Isaiah
    Dill, Allison L.
    Golby, Alexandra J.
    Ligon, Keith L.
    Santagata, Sandro
    Cooks, R. Graham
    Agar, Nathalie Y. R.
    [J]. CANCER RESEARCH, 2012, 72 (03) : 645 - 654