Test-retest reliability of clitoral blood flow measurements using color Doppler ultrasonography at rest and after a pelvic floor contraction task in healthy adult women

被引:8
作者
Mercier, Joanie [1 ]
Tang, An [2 ]
Morin, Melanie [3 ]
Khalife, Samir [4 ]
Lemieux, Marie-Claude [5 ]
Reichetzer, Barbara [6 ]
Dumoulin, Chantale [1 ]
机构
[1] Univ Montreal, Inst Univ Geriatrie Montreal, Res Ctr, Sch Rehabil,Fac Med, Montreal, PQ, Canada
[2] Ctr Hosp Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ, Canada
[3] Univ Sherbrooke, Ctr Hosp Univ Sherbrooke, Res Ctr, Fac Med,Sch Rehabil, Sherbrooke, PQ, Canada
[4] McGill Univ, Sir Mortimer B Davis Jewish Gen Hosp, Dept Obstet & Gynecol, Montreal, PQ, Canada
[5] Maisonneuve Rosemont Hosp, Dept Obstet & Gynecol, Montreal, PQ, Canada
[6] Univ Montreal, Ctr Hosp, Dept Obstet & Gynecol, Montreal, PQ, Canada
关键词
Doppler; dorsal clitoral artery; imaging; pelvic floor contractions; ultrasound; VASCULAR MODIFICATIONS; SEXUAL DYSFUNCTION; EXERCISE; MENOPAUSE; AROUSAL;
D O I
10.1002/nau.23582
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
AimsTest-retest reliability assessment of the dorsal clitoral artery's blood flow at rest and after muscle activation has never been documented. If this outcome measure is to be used in conditions impeding vascularity, it requires a psychometric evaluation. The aim of this study was to assess the inter-session test-retest reliability of clitoral blood flow in healthy women using color Doppler ultrasonography at rest and after a pelvic floor muscle (PFM) contraction task. MethodsTwo assessment sessions were conducted using a clinical ultrasound system. Clitoral blood flow measurements were repeated at rest and after a PFM contraction task. Measurements of the peak systolic velocity (PSV), time-averaged maximum velocity (TAMX), end-diastolic velocity (EDV), pulsatility index (PI), and resistance index (RI) were taken. The test-retest reliability was assessed using paired t-test, intraclass correlation coefficient (ICC), and Bland-Altman plots. ResultsFor reliability at rest, ICC values were 0.95 for PSV, 0.87 for TAMX, and 0.67 for both PI and RI. The variability between measurements, as per Bland-Altman plots, was small for PSV, TAMX, and RI and acceptable for PI. For reliability after the PFM contractions task, ICC values were 0.85 for PSV, 0.77 for TAMX, 0.79 for PI, and 0.81 for RI. The variability between measurements was small for PSV and RI and acceptable for TAMX and PI. EDV parameter did not perform as well in both conditions. ConclusionsAssessment of the clitoral blood flow with color Doppler ultrasound is reliable at rest and after a PFM contraction task.
引用
收藏
页码:2249 / 2256
页数:8
相关论文
共 26 条
[1]  
[Anonymous], 2017, CANC INTIMACY SEXUAL
[2]  
[Anonymous], 2011, DESIGN ANAL CLIN EXP
[3]   Periovulatory Morphometric and Vascular Modifications of the Clitoris in Young Adult and Middle-Aged Women. A Pilot Study [J].
Battaglia, Cesare ;
Nappi, Rossella Elena ;
Cianciosi, Arianna ;
Busacchi, Paolo ;
Sisti, Giovanni ;
Paradisi, Roberto ;
Venturoli, Stefano .
JOURNAL OF SEXUAL MEDICINE, 2009, 6 (10) :2707-2714
[4]   Menstrual Cycle-Related Morphometric and Vascular Modifications of the Clitoris [J].
Battaglia, Cesare ;
Nappi, Rossella Elena ;
Mancini, Fulvia ;
Cianciosi, Arianna ;
Persico, Nicola ;
Busacchi, Paolo ;
Facchinetti, Fabio ;
de Aloysio, Domenico .
JOURNAL OF SEXUAL MEDICINE, 2008, 5 (12) :2853-2861
[5]   Effects of Exercise Intensity on Flow Mediated Dilation in Healthy Humans [J].
Birk, G. K. ;
Dawson, E. A. ;
Batterham, A. M. ;
Atkinson, G. ;
Cable, T. ;
Thijssen, D. H. J. ;
Green, D. J. .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2013, 34 (05) :409-414
[6]   Investigation of Optimal Cues to Instruction for Pelvic Floor Muscle Contraction: A Pilot Study Using 2D Ultrasound Imaging in Pre-Menopausal, Nulliparous, Continent Women [J].
Crotty, Kay ;
Bartram, Clive I. ;
Pitkin, Joan ;
Cairns, Mindy C. ;
Taylor, Paul C. ;
Dorey, Grace ;
Chatoor, Dave .
NEUROUROLOGY AND URODYNAMICS, 2011, 30 (08) :1620-1626
[7]  
Culligan W., 2013, Yale J. Biol. Med, V86, P285
[8]  
Currier D.P., 1984, ELEMENTS RES PHYS TH, V2nd
[9]   Effects of caffeine on blood pressure, heart rate, and forearm blood flow during dynamic leg exercise [J].
Daniels, JW ;
Molé, PA ;
Shaffrath, JD ;
Stebbins, CL .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (01) :154-159
[10]  
Egginton S, 2008, PFLUGERS ARCH, V457, P963, DOI DOI 10.1007/S00424-008-0563-9.PMID:18704490