The Role of the Back Plate in Angle Anatomy with the Boston Type I Keratoprosthesis

被引:8
|
作者
Taniguchi, Elise V. [1 ,2 ]
Paschalis, Eleftherios I. [1 ]
Crnej, Alja [1 ]
Ren, Ai [1 ]
Colby, Kathryn A. [1 ,3 ]
Chodosh, James [1 ]
Pasquale, Louis R. [1 ]
Shen, Lucy Q. [1 ]
Dohlman, Claes H. [1 ]
Cruzat, Andrea [1 ,4 ]
机构
[1] Harvard Med Sch, Massachusetts Eye & Ear, Dept Ophthalmol, 243 Charles St, Boston, MA 02114 USA
[2] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[3] Univ Chicago, Med Ctr, Dept Ophthalmol, Chicago, IL 60637 USA
[4] Pontificia Univ Catolica Chile, Dept Ophthalmol, Santiago, Chile
关键词
Boston type I keratoprosthesis; anterior segment optical coherence tomography; anterior chamber angle anatomy; glaucoma; OPTICAL COHERENCE TOMOGRAPHY; GLAUCOMA DRAINAGE DEVICES; TERM OUTCOMES; IMPLANTATION; COMPLICATIONS; MULTICENTER; SURGERY; PROGRESSION; PREVENTION; RETENTION;
D O I
10.1097/ICO.0000000000001248
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To quantitatively evaluate the angle anatomy in eyes with the Boston type I keratoprosthesis (B-KPro) differing in the back plate (BP) material and size using anterior segment optical coherence tomography. Methods: B-KPro eyes with poly(methyl methacrylate) (PMMA) (7.0 and 8.5 mm) and titanium (7.0, 8.5, and 9.5 mm) BPs were imaged with anterior segment optical coherence tomography. The angle opening distance at 500 mu m from the scleral spur (AOD500), trabecular iris surface area at 500 mu m from the scleral spur (TISA500), and trabecular iris angle at 500 1.1m from the scleral spur (TIA500) were measured. Among the visible quadrants, the average, the temporal, the widest, and the narrowest angle of each eye were included in the analysis. Average time between B-KPro implantation and imaging was 7.5 +/- 1.4 years for a PMMA BP and 2.4 +/- 2.3 years for a titanium BP (P < 0.0001). Results: We analyzed 17 B-KPro eyes with PMMA BPs and 24 B-KPro eyes with titanium BPs. The average AOD500 (394.1 +/- 226.9 vs. 454.5 +/- 255.6 mu m, P = 0.44), average TIA500 (26.2 +/- 14.2 vs. 29.8 +/- 13.9 degrees, P = 0.43), and average TISA500 (0.15 +/- 0.08 vs. 0.17 +/- 0.10 mu m(2), P = 0.52) were not statistically different between eyes with PMMA and titanium BPs, nor were the temporal, the narrowest, and the widest angle measurements of each eye (all P > 0.05). Similarly, no significant differences were found between the angle measurements of B-KPro eyes with a titanium BP diameter of 8.5 or 9.5 mm (all P > 0.05). Conclusions: We successfully visualized the angle anatomy in 66.1% of the imaged eyes, including all BPs studied. Neither the material nor the size of the B-KPro BP had a significant impact on the angle anatomy.
引用
收藏
页码:1096 / 1101
页数:6
相关论文
共 50 条
  • [31] Glaucoma Management in Patients With Aniridia and Boston Type 1 Keratoprosthesis
    Nascimento E Silva, Rafaella
    Shen, Lucy Q.
    Chiou, Carolina A.
    Shanbhag, Swapna S.
    Paschalis, Eleftherios I.
    Pasquale, Louis R.
    Colby, Kathryn A.
    Lman, Claes H. Doh
    Chodosh, James
    Alves, Milton R.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 207 : 258 - 267
  • [32] Management of glaucoma with Boston type 1 keratoprosthesis
    Utine, Canan Asli
    Arikan, Gul
    Yardim, Elvan
    Gunenc, Uzeyir
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2023, 86 (02) : 137 - 144
  • [33] Predictors of Visual Outcomes Following Boston Type 1 Keratoprosthesis Implantation
    Ahmad, Sumayya
    Akpek, Esen K.
    Gehlbach, Peter L.
    Dunlap, Karen
    Ramulu, Pradeep Y.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (04) : 739 - 747
  • [34] Chronic Hypotony Associated With the Boston Type 1 Keratoprosthesis
    Dokey, Adrian
    Ramulu, Pradeep Y.
    Utine, Canan A.
    Tzu, Jonathan H.
    Eberhart, Charles G.
    Shan, Shannon
    Gelhbach, Peter L.
    Akpek, Esen K.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (02) : 266 - 271
  • [35] Experience with Boston keratoprosthesis type 1 in the developing world
    de Oliveira, Lauro Augusto
    Magalhaes, Fernanda Pedreira
    Hirai, Flavio E.
    de Sousa, Luciene Barbosa
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2014, 49 (04): : 351 - 357
  • [36] Ten-Year Outcome of Boston Type I Keratoprosthesis Surgery at a Tertiary Care Center
    Tsou, Brittany C.
    Koseoglu, N. Dilruba
    Akpek, Esen K.
    Liu, T. Y. Alvin
    CORNEA, 2024, 43 (08) : 982 - 988
  • [37] Comparison of the Clinical Efficacy of Boston Keratoprosthesis Type I and Repetitive Penetrating Keratoplasty for Refractory Keratopathy
    Chen, Yingxin
    Wang, Cuiyu
    Liu, Qiming
    Wang, Ziyue
    Gao, Minghong
    JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (02) : E194 - E199
  • [38] Improving glaucoma management for the Boston keratoprosthesis type 1: tubes versus lasers
    Geoffrion, Dominique
    Harissi-Dagher, Mona
    EXPERT REVIEW OF OPHTHALMOLOGY, 2020, 15 (06) : 313 - 320
  • [39] POSTOPERATIVE POSTERIOR SEGMENT COMPLICATIONS IN EYES TREATED WITH THE BOSTON TYPE I KERATOPROSTHESIS
    Goldman, Darin R.
    Hubschman, Jean-Pierre
    Aldave, Anthony J.
    Chiang, Allen
    Huang, Jennifer S.
    Bourges, Jean-Louis
    Schwartz, Steven D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2013, 33 (03): : 532 - 541
  • [40] The Boston Type I Keratoprosthesis: An Assessment of Its Efficacy and Safety
    Verdejo-Gomez, Lucia
    Pelaez, Natalia
    Gris, Oscar
    Luis Gueell, Jose
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (06) : 446 - 452