Energy matching analysis for net-zero energy buildings

被引:11
作者
Mohamed, Ayman [1 ,2 ]
Hasan, Ala [3 ]
机构
[1] Aalto Univ, Dept Energy Technol, Sch Engn, POB 14400, FI-00076 Aalto, Finland
[2] Helwan Univ, Dept Power Mech Engn, Fac Engn Mattaria, Cairo, Egypt
[3] VTT, VTT Tech Res Ctr Finland, Espoo, Finland
基金
芬兰科学院;
关键词
SINGLE-FAMILY HOUSE; MICRO-COGENERATION; SMALL-SCALE; FUEL-CELL; BIOMASS; PERFORMANCE; NZEB;
D O I
10.1080/23744731.2016.1176850
中图分类号
O414.1 [热力学];
学科分类号
摘要
A net zero energy building is a grid connected building that exports as much energy as it imports over a predefined period of time based on a certain balance metric. Energy matching defines how much the building load covered with its own generation, as well as the interplay with the surrounding grids. This study aims to investigate the energy matching of a building and its effect on categorizing its net zero energy building balance options. Three common net zero energy building balance metrics are considered: site-energy, primary energy, and CO2-eq emission based on Finnish reference data. A single family house located in Helsinki, Finland served by four conventional heating systems and seven biomass-based co-generation heat and power technologies are simulated using a simulation-based model software. A photovoltaic (PV) system is a supplementary system that can bring the building to a balanced status, when needed. Energy matching is analyzed under the consideration that the building is connected with the bi-direction electrical grid. The results show that the lowest imported weighted energy does not necessarily represent the best net zero energy building case. The energy matching analysis could become another criterion for the best net zero energy building case selection. The co-generation heat and power technologies show a better energy matching situation than the conventional heating systems fulfilling all of the net zero energy building balances investigated.
引用
收藏
页码:885 / 901
页数:17
相关论文
共 21 条
[1]  
[Anonymous], 2012, FINL COD BUILD REG C
[2]  
[Anonymous], 2012, FINL COD BUILD REG E
[3]  
Candanedo J., 2015, Modeling, Design, and Optimization of Net-Zero Energy Buildings, P207, DOI [10.1002/9783433604625.ch06, DOI 10.1002/9783433604625.CH06]
[4]   Energy matching analysis of on-site micro-cogeneration for a single-family house with thermal and electrical tracking strategies [J].
Cao, Sunliang ;
Mohamed, Ayman ;
Hasan, Ala ;
Siren, Kai .
ENERGY AND BUILDINGS, 2014, 68 :351-363
[5]   On-site energy matching indices for buildings with energy conversion, storage and hybrid grid connections [J].
Cao, Sunliang ;
Hasan, Ala ;
Siren, Kai .
ENERGY AND BUILDINGS, 2013, 64 :423-438
[6]   Performance assessment of fuel cell micro-cogeneration systems for residential buildings [J].
Dorer, V ;
Weber, R ;
Weber, A .
ENERGY AND BUILDINGS, 2005, 37 (11) :1132-1146
[7]   The externally-fired gas-turbine (EFGT-Cycle) for decentralized use of biomass [J].
Kautz, Martin ;
Hansen, Ulf .
APPLIED ENERGY, 2007, 84 (7-8) :795-805
[8]  
Laitinen A., 2005, SPECIFICATION RET SI
[9]   The performance of small scale multi-generation technologies in achieving cost-optimal and zero-energy office building solutions [J].
Mohamed, Ayman ;
Hamdy, Mohamed ;
Hasan, Ala ;
Siren, Kai .
APPLIED ENERGY, 2015, 152 :94-108
[10]   Selection of micro-cogeneration for net zero energy buildings (NZEB) using weighted energy matching index [J].
Mohamed, Ayman ;
Cao, Sunliang ;
Hasan, Ala ;
Siren, Kai .
ENERGY AND BUILDINGS, 2014, 80 :490-503