Visual Field Testing with Head-Mounted Perimeter 'imo'

被引:64
作者
Matsumoto, Chota [1 ]
Yamao, Sayaka [1 ]
Nomoto, Hiroki [1 ]
Takada, Sonoko [1 ]
Okuyama, Sachiko [1 ]
Kimura, Shinji [2 ]
Yamanaka, Kenzo [2 ]
Aihara, Makoto [3 ,4 ]
Shimomura, Yoshikazu [1 ]
机构
[1] Kindai Univ, Fac Med Osaka Sayama City, Dept Ophthalmol, Osaka, Japan
[2] CREWT Med Syst Inc, Tokyo, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Ophthalmol, Tokyo, Japan
[4] Univ Tokyo, Fac Med, Tokyo, Japan
关键词
FREQUENCY-DOUBLING TECHNOLOGY; ADAPTATION;
D O I
10.1371/journal.pone.0161974
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose We developed a new portable head-mounted perimeter, "imo", which performs visual field (VF) testing under flexible conditions without a dark room. Besides the monocular eye test, imo can present a test target randomly to either eye without occlusion (a binocular random single eye test). The performance of imo was evaluated. Methods Using full HD transmissive LCD and high intensity LED backlights, imo can display a test target under the same test conditions as the Humphrey Field Analyzer (HFA). The monocular and binocular random single eye tests by imo and the HFA test were performed on 40 eyes of 20 subjects with glaucoma. VF sensitivity results by the monocular and binocular random single eye tests were compared, and these test results were further compared to those by the HFA. The subjects were asked whether they noticed which eye was being tested during the test. Results The mean sensitivity (MS) obtained with the HFA highly correlated with the MS by the imo monocular test (R: r = 0.96, L: r = 0.94, P < 0.001) and the binocular random single eye test (R: r = 0.97, L: r = 0.98, P < 0.001). The MS values by the monocular and binocular random single eye tests also highly correlated (R: r = 0.96, L: r = 0.95, P < 0.001). No subject could detect which eye was being tested during the examination. Conclusions The perimeter imo can obtain VF sensitivity highly compatible to that by the standard automated perimeter. The binocular random single eye test provides a non-occlusion test condition without the examinee being aware of the tested eye.
引用
收藏
页数:12
相关论文
共 12 条
[1]   Normal aging effects for frequency doubling technology perimetry [J].
Adams, CW ;
Bullimore, MA ;
Wall, M ;
Fingeret, M ;
Johnson, CA .
OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) :582-587
[2]   Effect of dichoptic adaptation on frequency-doubling perimetry [J].
Anderson, AJ ;
Johnson, CA .
OPTOMETRY AND VISION SCIENCE, 2002, 79 (02) :88-92
[3]   Quantifying adaptation and fatigue effects in frequency doubling perimetry [J].
Anderson, Andrew John ;
McKendrick, Allison Maree .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (02) :943-948
[4]  
Artes PH, 2002, INVEST OPHTH VIS SCI, V43, P2654
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   GANZFELD BLANKOUT OCCURS IN BOWL PERIMETRY AND IS ELIMINATED BY TRANSLUCENT OCCLUSION [J].
FUHR, PS ;
HERSHNER, TA ;
DAUM, KM .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (07) :983-988
[7]   Use of a portable head mounted perimetry system to assess bedside visual fields [J].
Hollander, DA ;
Volpe, NJ ;
Moster, ML ;
Liu, GT ;
Balcer, LJ ;
Judy, KD ;
Galetta, SL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (10) :1185-1190
[8]   Effect of decreased retinal illumination on frequency doubling technology [J].
Kogure, S ;
Membrey, WL ;
Fitzke, FW ;
Tsukahara, S .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2000, 44 (05) :489-493
[9]   Validation of a new static perimetric thresholding strategy (GATE) [J].
Luithardt, Annette Franziska ;
Meisner, Christoph ;
Monhart, Matthias ;
Krapp, Elke ;
Mast, Andrea ;
Schiefer, Ulrich .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (01) :11-15
[10]  
Nagata S, 1997, PERIMETRY UPDATE 198, P337