Disagreement between pulse contour analysis and transpulmonary thermodilution for cardiac output monitoring after routine therapeutic interventions in ICU patients with acute circulatory failure

被引:27
作者
Muller, Laurent [1 ,2 ]
Candela, Damien [1 ,2 ]
Nyonzyma, Lambert [3 ]
Mattatia, Laurent [1 ,2 ]
Suehs, Carey [4 ]
Fabbro-Peray, Pascale [4 ]
Louart, Guillaume [1 ,2 ]
de La Coussaye, Jean E. [1 ,2 ]
Jaber, Samir [5 ]
Leone, Marc [1 ,6 ]
Lefrant, Jean-Y [1 ,2 ]
机构
[1] Univ Nimes Hosp, Dept Anesthesiol Crit Care Emergency & Pain, F-30006 Nimes, France
[2] Univ Montpellier 1, Med Sch Montpellier Nimes, Cardiovasc & Expt Anaesthesia Lab Vasc Interfaces, EA 2992, Nimes, France
[3] Hosp Moulins Yzeure, Dept Anesthesiol, Moulins, France
[4] Univ Nimes Hosp, Dept Epidemiol & Biostat, F-30006 Nimes, France
[5] Univ Hosp Montpellier, St Eloi Hosp, Dept Anesthesiol & Crit Care B, Montpellier, France
[6] Univ Aix Marseille 2, Hop Nord, Assistance Publ Hop Marseille, Dept Anaesthesia & Crit Care, Marseille, France
关键词
cardiac output measurement; intensive care; pulse contour; therapeutic interventions; transpulmonary thermodilution; CRITICALLY-ILL PATIENTS; ARTERIAL THERMODILUTION; PULMONARY-ARTERY; RELIABILITY; CATHETERIZATION; VENTILATION; AGREEMENT; ACCURACY; PRESSURE; HEART;
D O I
10.1097/EJA.0b013e328346adda
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective The present prospective study was aimed at assessing the reliability of the pulse contour method for measuring cardiac output (CO) after different routinely used therapeutic interventions that can influence vascular compliance and systemic vascular resistances in ICU patients (fluid challenges, changes in norepinephrine or dobutamine infusion rates and changes in ventilatory settings). Methods In ICU patients requiring CO monitoring, transpulmonary thermodilution CO (CO(TD)) and pulse contour CO (CO(PC)) were measured with a PiCCO device after therapeutic manoeuvre-free periods (<= and > 1 h) and after therapeutic interventions without recalibration. Results Three hundred fifty-two sets of CO measurement pairs in 63 ICU patients were performed. The biases (and percentage errors) between CO(PC) and CO(TD) for the overall paired measurement, therapeutic manoeuvre-free periods and therapeutic manoeuvres were 0.20 +/- 1.09 (33%), -0.01 +/- 0.93 (29%) and 0.37 +/- 1.18 (34%), respectively. The percentage errors were 36 and 39% for fluid challenges and changes in norepinephrine infusion rate, respectively. Conclusion In ICU patients requiring therapeutic interventions, CO(PC) is frequently in disagreement with CO(TD). Eur J Anaesthesiol 2011; 28: 664-669 Published online 12 May 2011
引用
收藏
页码:664 / 669
页数:6
相关论文
共 27 条
[1]   The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration [J].
Bein, Berthold ;
Meybohm, Patrick ;
Cavus, Erol ;
Renner, Jochen ;
Tonner, Peter H. ;
Steinfath, Markus ;
Scholz, Jens ;
Doerges, Volker .
ANESTHESIA AND ANALGESIA, 2007, 105 (01) :107-113
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[4]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[5]   Injuries and liability related to central vascular catheters - A closed claims analysis [J].
Domino, KB ;
Bowdle, TA ;
Posner, KL ;
Spitellie, PH ;
Lee, LA ;
Cheney, FW .
ANESTHESIOLOGY, 2004, 100 (06) :1411-1418
[6]   CHARACTERIZATION OF INTENSIVE-CARE UNIT PATIENTS USING A MODEL-BASED ON THE PRESENCE OR ABSENCE OF ORGAN DYSFUNCTIONS AND OR INFECTION - THE ODIN MODEL [J].
FAGON, JY ;
CHASTRE, J ;
NOVARA, A ;
MEDIONI, P ;
GIBERT, C .
INTENSIVE CARE MEDICINE, 1993, 19 (03) :137-144
[7]   Is It a Bird? Is It a Plane? The Role of Patient Monitors in Medical Decision Making [J].
Feldman, Jeffrey M. .
ANESTHESIA AND ANALGESIA, 2009, 108 (03) :707-710
[8]   Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting [J].
Funk, Duane J. ;
Moretti, Eugene W. ;
Gan, Tong J. .
ANESTHESIA AND ANALGESIA, 2009, 108 (03) :887-897
[9]   A TRIAL OF GOAL-ORIENTED HEMODYNAMIC THERAPY IN CRITICALLY ILL PATIENTS [J].
GATTINONI, L ;
BRAZZI, L ;
PELOSI, P ;
LATINI, R ;
TOGNONI, G ;
PESENTI, A ;
FUMAGALLI, R .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (16) :1025-1032
[10]  
Gödje O, 2002, CRIT CARE MED, V30, P52