Experimental study of solving thermal heterogeneity problem of data center servers

被引:32
作者
Nada, S. A. [1 ]
Attia, Ali M. A. [1 ]
Elfeky, K. E. [1 ]
机构
[1] Benha Univ, Benha Fac Engn, Dept Mech Engn, Banha 13511, Egypt
关键词
Data center; Energy management; Heterogeneous temperature management; Servers fans speeds; TEMPERATURE; MANAGEMENT; FLOW;
D O I
10.1016/j.applthermaleng.2016.08.097
中图分类号
O414.1 [热力学];
学科分类号
摘要
Desirable thermal management of data center requires uniform temperature distribution along the servers. Hot air recirculation and cold air bypass in data center leads to non-homogeneous cold air distribution along the servers of the racks which may lead to heterogeneous temperatures distribution along the servers. The present work aims to experimentally study the possibility of controlling these heterogeneous temperature distributions by controlling the cold air flow rates along the servers. A physical scaled data center model was used to conduct this investigation. The effectiveness of thermal management of the servers racks of the data centers has been expressed in terms of intake, rare and surface temperature distributions along the rack servers and the supply and return heat indices (commonly symbolized as SHI and RHI; respectively). Excessive tests were firstly performed under uniform servers fans speed (uniform air flow rates through the different servers). Then the air flow rates distributions along the racks servers has been changed by regulating the server's fans speeds using different schemes of fans speeds regulations at different data centers power densities. It is concluded that a uniform increase of server's flow rate from the bottom to the top of servers rack cabinet provides (i) the lowest temperature at both cooling aisle (around 10%) and exhaust aisles (around 5%), (ii) the best uniform surface temperature of all rack servers (as the standard deviation is reduced from 10 to around 2), and (iii) the best values of thermal management metrics (SHI and RHI) typically SHI is reduced by around 20% while RHI is increased by around 3% to approach the targeted values; 0.1 and 0.9, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:466 / 474
页数:9
相关论文
共 35 条
  • [1] [Anonymous], 2011, THERM GUID DAT PROC, P1
  • [2] SCALE EFFECT IN ROOM AIR-FLOW STUDIES
    AWBI, HB
    NEMRI, MM
    [J]. ENERGY AND BUILDINGS, 1990, 14 (03) : 207 - 210
  • [3] Viability of dynamic cooling control in a data center environment
    Boucher, Timothy D.
    Auslander, David M.
    Bash, Cullen E.
    Federspiel, Clifford C.
    Patel, Chandrakant D.
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2006, 128 (02) : 137 - 144
  • [4] Breen T. J., 2011, J ELECTRON PACKAGING, V133, P1, DOI DOI 10.1115/1.400327.PP.011004-011004-8
  • [5] From Chip to Cooling Tower Data Center Modeling: Chip Leakage Power and Its Impact on Cooling Infrastructure Energy Efficiency
    Breen, Thomas J.
    Walsh, Ed J.
    Punch, Jeff
    Shah, Amip J.
    Bash, Cullen E.
    Kumari, Niru
    Cader, Tahir
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2012, 134 (04)
  • [6] Thermal metrics for data centers: a critical review
    Capozzoli, Alfonso
    Serale, Gianluca
    Liuzzo, Lucia
    Chinnici, Marta
    [J]. 6TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, 2014, 62 : 391 - 400
  • [7] Measurements and predictions of the air distribution systems in high compute density (Internet) data centers
    Cho, Jinkyun
    Lim, Taesub
    Kim, Byungseon Sean
    [J]. ENERGY AND BUILDINGS, 2009, 41 (10) : 1107 - 1115
  • [8] Demetriou D. W., 2012, THESIS
  • [9] Simulation of a temperature adaptive control strategy for an IWSE economizer in a data center
    Durand-Estebe, Baptiste
    Le Bot, Cedric
    Mancos, Jean Nicolas
    Arquis, Eric
    [J]. APPLIED ENERGY, 2014, 134 : 45 - 56
  • [10] Fernando H, 2012, INT CONF INF AUTOMAT, P273, DOI 10.1109/ICIAFS.2012.6419916