Parallel transmission for ultrahigh-field imaging

被引:152
作者
Padormo, Francesco [1 ]
Beqiri, Arian [1 ]
Hajnal, Joseph V. [1 ,2 ]
Malik, Shaihan J. [1 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, Dept Biomed Engn, Kings Hlth Partners,St Thomas Hosp, London, England
[2] Kings Coll London, Div Imaging Sci & Biomed Engn, Ctr Dev Brain, Kings Hlth Partners,St Thomas Hosp, London, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会; 英国惠康基金;
关键词
ultrahigh-field MRI; parallel transmission; RF shimming; SAR; B-1; mapping; RF PULSE DESIGN; SPATIALLY-SELECTIVE EXCITATION; GRADIENT WAVE-FORMS; TO-NOISE RATIO; CARDIOVASCULAR MAGNETIC-RESONANCE; TIME-INTERLEAVED ACQUISITION; REDUCED B-1 INHOMOGENEITY; ENERGY-ABSORPTION RATE; HUMAN BRAIN; TESLA;
D O I
10.1002/nbm.3313
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of MRI systems operating at or above 7T has provided researchers with a new window into the human body, yielding improved imaging speed, resolution and signal-to-noise ratio. In order to fully realise the potential of ultrahigh-field MRI, a range of technical hurdles must be overcome. The non-uniformity of the transmit field is one of such issues, as it leads to non-uniform images with spatially varying contrast. Parallel transmission (i.e. the use of multiple independent transmission channels) provides previously unavailable degrees of freedom that allow full spatial and temporal control of the radiofrequency (RF) fields. This review discusses the many ways in which these degrees of freedom can be used, ranging from making more uniform transmit fields to the design of subject-tailored RF pulses for both uniform excitation and spatial selection, and also the control of the specific absorption rate. (c) 2015 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.
引用
收藏
页码:1145 / 1161
页数:17
相关论文
共 223 条
  • [11] Balchandani P., 2011, Proceedings of the 19th Scientific Meeting, P2907
  • [12] Improved Slice-Selective Adiabatic Excitation
    Balchandani, Priti
    Glover, Gary
    Pauly, John
    Spielman, Daniel
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 75 - 82
  • [13] SAR OPTIMIZATION IN A PHASED-ARRAY RADIOFREQUENCY HYPERTHERMIA SYSTEM
    BARDATI, F
    BORRANI, A
    GERARDINO, A
    LOVISOLO, GA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (12) : 1201 - 1207
  • [14] Beqiri A, 2014, P JOINT ANN M ISMRM, P179
  • [15] Multislice 1H MRSI of the human brain at 7 T using dynamic B0 and B1 shimming
    Boer, Vincent O.
    Klomp, Dennis W. J.
    Juchem, Christoph
    Luijten, Peter R.
    de Graaf, Robin A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 662 - 670
  • [16] Radiofrequency Pulse Design in Parallel Transmission Under Strict Temperature Constraints
    Boulant, Nicolas
    Massire, Aurelien
    Amadon, Alexis
    Vignaud, Alexandre
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 679 - 688
  • [17] Design and Application of Combined 8-Channel Transmit and 10-Channel Receive Arrays and Radiofrequency Shimming for 7-T Shoulder Magnetic Resonance Imaging
    Brown, Ryan
    Deniz, Cem Murat
    Zhang, Bei
    Chang, Gregory
    Sodickson, Daniel K.
    Wiggins, Graham C.
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (01) : 35 - 47
  • [18] Brunner D, 2008, P 16 ANN M ISMRM TOR, P615
  • [19] Optimal Design of Multiple-Channel RF Pulses Under Strict Power and SAR Constraints
    Brunner, David O.
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1280 - 1291
  • [20] B1+ Interferometry for the Calibration of RF Transmitter Arrays
    Brunner, David O.
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1480 - 1488