Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer

被引:259
作者
Underberg, RWM [1 ]
Lagerwaard, FJ [1 ]
Slotman, BJ [1 ]
Cuijpers, JP [1 ]
Senan, S [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Radiat Oncol, NL-1007 MB Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2005年 / 63卷 / 01期
关键词
4DCT scans; internal target volume; lung cancer; maximum intensity projection;
D O I
10.1016/j.ijrobp.2005.05.045
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Single four-dimensional CT (4DCT) scans reliably capture intrafractional tumor mobility for radiotherapy planning, but generating internal target volumes (ITVs) requires the contouring of gross tumor volumes (GTVs) in up to 10 phases of a 4DCT scan, as is routinely performed in our department. We investigated the use of maximum intensity projection (MIP) protocols for rapid generation of ITVs. Methods and Materials: 4DCT data from a mobile phantom and from 12 patients with Stage I lung cancer were analyzed. A single clinician contoured GTVs in all respiratory phases of a 4DCT, as well as in three consecutive phases selected for respiratory gating. MIP images were generated from both phantom and patient data, and ITVs were derived from encompassing volumes of the respective GTVs. Results: In the phantom study, the ratio between ITVs generated from all 10 phases and those from MIP scans was 1.04. The corresponding center of mass of both ITVs differed by less than 1 mm. In scans from patients, good agreement was observed between ITVs derived from 10 and 3 (gating) phases and corresponding MIPs, with ratios of 1.07 +/- 0.05 and 0.98 +/- 0.05, respectively. In addition, the center of mass of the respective ITVs differed by only 0.4 and 0.5 mm. Conclusion: MIPs are a reliable clinical tool for generating ITVs from 4DCT data sets, thereby permitting rapid assessment of mobility for both gated and nongated 4D radiotherapy in lung cancer. (c) 2005 Elsevier Inc.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 23 条
  • [1] CT techniques for imaging the lung: recommendations for multislice and single slice computed tomography
    Aziz, ZA
    Padley, SP
    Hansell, DM
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2004, 52 (02) : 119 - 136
  • [2] AAPM/RSNA physics tutorial for residents: Topics in CT - Image processing in CT
    Cody, DD
    [J]. RADIOGRAPHICS, 2002, 22 (05) : 1255 - 1268
  • [3] Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe?
    De Koste, JRV
    Lagerwaard, FJ
    de Boer, HCJ
    Nijssen-Visser, MR
    Senan, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05): : 1394 - 1399
  • [4] Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans
    de Koste, JRV
    Lagerwaard, FJ
    Nijssen-Visser, MRJ
    Graveland, WJ
    Senan, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02): : 348 - 354
  • [5] Dosimetric consequences of tumor mobility in radiotherapy of stage I non-small cell lung cancer - an analysis of data generated using 'slow' CT scans
    de Koste, JRV
    Lagerwaard, FJ
    Schuchhard-Schipper, RH
    Nijssen-Visser, MRJ
    Voet, PWJ
    Oei, SS
    Senan, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 61 (01) : 93 - 99
  • [6] Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT
    Gruden, JF
    Ouanounou, S
    Tigges, S
    Norris, SD
    Klausner, TS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (01) : 149 - 157
  • [7] International Commission in Radiation Units and Measurements, 1999, 62 ICRU
  • [8] Evaluation of small pulmonary arteries by 16-slice multidetector computed tomography - Optimum slab thickness in condensing transaxial images converted into maximum intensity projection images
    Jeong, YJ
    Lee, KS
    Yoon, YC
    Kim, TS
    Chung, MJ
    Kim, S
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (02) : 195 - 203
  • [9] 4-dimensional computed tomography imaging and treatment planning
    Keall, P
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 81 - 90
  • [10] Multiple "slow" CT scans for incorporating lung tumor mobility in radiotherapy planning
    Lagerwaard, FJ
    de Koste, JRV
    Nijssen-Visser, MRJ
    Schuchhard-Schipper, RH
    Oei, SS
    Munne, A
    Senan, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04): : 932 - 937