Effect on the bactericidal device for decontamination the air microorganisms in poultry house on the content of toxic gases

被引:1
|
作者
Palii, A. P. [1 ]
Nanka, O., V [1 ]
Kovalchuk, Y. O. [2 ]
Kovalchuk, A. O. [3 ]
Kalabska, V. S. [4 ]
Kholod, I., V [4 ]
Pobirchenko, O. M. [4 ]
Umrihina, O. S. [4 ]
Poliakov, A. M. [5 ]
Ishchenko, K., V [1 ]
Paliy, A. P. [6 ]
机构
[1] Kharkiv Natl Tech Univ Agr, Str Alchevskih 44, UA-61002 Kharkiv, Ukraine
[2] Uman Natl Univ Hort, Prov Int 1, UA-20305 Uman, Cherkasy Region, Ukraine
[3] Ivan Kozhedub Kharkiv Natl Air Force Univ, Str Sumska 77-79, UA-61023 Kharkiv, Ukraine
[4] Pavlo Tychyna Uman State Pedag Univ, Str Sadova 2, UA-20300 Uman, Cherkassy Regio, Ukraine
[5] Luhansk Natl Agr Univ, Str Slobozhanska 68, UA-92703 Starobelsk, Ukraine
[6] Inst Expt & Clin Vet Med, Natl Sci Ctr, Str Pushkinska 83, UA-61023 Kharkiv, Ukraine
来源
UKRAINIAN JOURNAL OF ECOLOGY | 2020年 / 10卷 / 01期
关键词
Poultry house; Microclimate; Air; Bacterial contamination; Toxic gases; Ultraviolet irradiation; PROCESSING EQUIPMENT; SYSTEMS;
D O I
10.15421/2020_4
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Litter in the poultry house is a source of toxic gases (ammonia, hydrogen sulphide and carbon dioxide), dust, and is a favourable place for the life and reproduction of microorganisms and helminths. The number of these secretions in the poultry house depends on many factors: the sanitary status of the poultry house, the species, the age of the birds, the microclimate, the season, feeding conditions, and so on. The purpose of the research was to substantiate the rational construction and modes of operation of the device for the decontamination of microorganisms in the air of the poultry house on the basis of the use of sources of ultraviolet irradiation. The necessity of development and application techniques for cage batteries with a litter removal belt system which provide reduction of microbial contamination of air in poultry houses and the content of harmful gases in it have been substantiated. The device was developed and the effective mode of disinfection of the air of the poultry house in the collector air duct of the litter drying system based on the use of sources of ultraviolet irradiation was determined. The application of the bactericidal device made it possible to reduce microbial air contamination on the 1st day of accumulation of the litter during the cold season - by 2.6 times, in the transitional season - by 2.1 times; on 5th day, the accumulation of the litter decreased by 3.0 and 2.3 times, respectively. During the operation of the air irradiation system, the content of toxic gases in it decreased compared to the period when the air was not treated with the ultraviolet irradiation - ammonia by 19.7% and carbon dioxide by 5.9%. The absolute values of microbial air contamination in the poultry house and the toxic gas content in the transitional season were lower than in the cold season, due to the higher indoor air exchange and the increase of clean outside air in the proportion. The difference in microbial air contamination between the basic and the proposed variants in the cold and transitional seasons was statistically significant.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 12 条
  • [1] Investigation of microclimate parameters for the content of toxic gases in poultry houses during air treatment in the scrubber with the use of various fillers
    Ishchenko, K. V.
    Palii, A. P.
    Kis, V. M.
    Petrov, R. V.
    Nagorna, L. V.
    Dolbanosova, R. V.
    Paliy, A. P.
    UKRAINIAN JOURNAL OF ECOLOGY, 2019, 9 (02): : 74 - 80
  • [2] Effect of Inner Environmental Conditions of Poultry House on Harmful Gases and Dust
    Kocaman, Bahar
    Yanik, Recep
    Yaganoglu, Aycan Mutlu
    JOURNAL OF ANIMAL AND VETERINARY ADVANCES, 2012, 11 (08): : 1275 - 1277
  • [3] Design and experiment of the filtration and cleaning device for air emitted from poultry house
    Liu C.
    Shi L.
    Li Z.
    Zheng W.
    Zhang Z.
    Yang L.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2023, 39 (02): : 166 - 172
  • [4] Improved techniques for the reduction of microbial contamination toxic gas content in the air of the poultry houses
    Palii, A. P.
    Lukyanov, I. M.
    Gurskyi, P., V
    Svirgun, O. A.
    Chaly, I., V
    Milenin, A. M.
    Tokolov, Yu, I
    Grebnova, I., V
    Kovalchuk, A. O.
    Boyko, Y. A.
    Paliy, A. P.
    UKRAINIAN JOURNAL OF ECOLOGY, 2020, 10 (02): : 398 - 403
  • [5] Pollutant Gases to Algal Animal Feed: Impacts of Poultry House Exhaust Air on Amino Acid Profile of Algae
    Uguz, Seyit
    Sozcu, Arda
    ANIMALS, 2024, 14 (05):
  • [6] EFFECT OF FORM AND LEVEL OF NITROGEN IN DIET FOR SHEEP ON AMMONIA CONTENT IN RUMEN GASES AND SURROUNDING AIR
    JANOWSKI, T
    OSTROWSKI, H
    BULLETIN DE L ACADEMIE POLONAISE DES SCIENCES-SERIE DES SCIENCES BIOLOGIQUES, 1969, 17 (11-1): : 703 - +
  • [7] THE EFFECT OF MANAGEMENT ON THE VITAMIN-B12 CONTENT OF POULTRY HOUSE LITTER .2. AS DETERMINED BY MICROBIOLOGICAL ASSAY
    HALBROOK, ER
    SUTTON, TS
    WINTER, AR
    POULTRY SCIENCE, 1950, 29 (05) : 679 - 684
  • [8] THE EFFECT OF MANAGEMENT ON THE VITAMIN-B12 CONTENT OF POULTRY HOUSE LITTER .1. AS MEASURED BY CHICK GROWTH
    HALBROOK, ER
    WINTER, AR
    SUTTON, TS
    POULTRY SCIENCE, 1950, 29 (05) : 672 - 678
  • [9] Effect of Disinfectants on Physicochemical Parameters of Litter, Microbiological Quality of Poultry House Air, Health Status and Performance of Broiler Chickens
    Mituniewicz, T.
    Sowinska, J.
    Wojcik, A.
    Iwanczuk-Czernik, K.
    Witkowska, D.
    Banas, J.
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2008, 17 (05): : 745 - 750
  • [10] Singlet oxygen generated by a new nonthermal atmospheric pressure air plasma device exerts a bactericidal effect on oral pathogens
    Hirano, Yoriyuki
    Hayashi, Makoto
    Tamura, Muneaki
    Yoshino, Fumihiko
    Yoshida, Ayaka
    Masubuchi, Mitsuaki
    Imai, Kenichi
    Ogiso, Bunnai
    JOURNAL OF ORAL SCIENCE, 2019, 61 (04) : 521 - 525