Quantitative assessment of in vitro jets based on three-dimensional color Doppler reconstruction

被引:4
作者
Guo, ZY [1 ]
Boughner, DR
Dietrich, JM
Pflugfelder, PW
Durand, LG
Loew, M
Fenster, A
机构
[1] George Washington Univ, Dept Elect & Comp Engn, Washington, DC 20052 USA
[2] John P Robarts Res Inst, Imaging Res Labs, London, ON, Canada
[3] Clin Res Inst Montreal, Biomed Engn Lab, Montreal, PQ H2W 1R7, Canada
关键词
free jet; color Doppler; three-dimensional imaging; regurgitation;
D O I
10.1016/S0301-5629(00)00337-9
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Three-dimensional (3-D) color Doppler imaging of flow jets was performed to investigate the effects of flow rate and orifice size on jet volumes. Flow jets were generated using a how model to simulate mitral regurgitation. This flow model consisted of a ventricular chamber, a valvular plate and an atrial chamber, Steady Bow was driven through circular orifices having diameters of 2.5, 3.5, 4.5, and 6 mm, respectively, with flow rates of 5, 10, 15, 20, and 25 mL/s to form free jets in the atrial chamber. An ATL Ultramark 9 HDI system was used to perform 3-D color Doppler imaging of the Bow jets. A transesophageal probe was rotated by a stepper motor to create 3-D color Doppler images of the jets. The color jet volumes for different hemodynamic conditions were measured and then compared with the theoretical predictions. Results showed that the jet volume estimated from the 3-D color Doppler was directly proportional to the flow rate and inversely proportional to the orifice size. The estimated jet volumes correlated well (r > 0.95) with theoretical predictions, This study supports the use of color jet volume as a parameter to quantify mitral regurgitation, (C) 2001 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:235 / 243
页数:9
相关论文
共 23 条
[1]   3-DIMENSIONAL AND 4-DIMENSIONAL CARDIOVASCULAR ULTRASOUND IMAGING - A NEW ERA FOR ECHOCARDIOGRAPHY [J].
BELOHLAVEK, M ;
FOLEY, DA ;
GERBER, TC ;
KINTER, TM ;
GREENLEAF, JF ;
SEWARD, JB .
MAYO CLINIC PROCEEDINGS, 1993, 68 (03) :221-240
[2]  
Belohlavek M, 1994, J Am Soc Echocardiogr, V7, P553
[3]   A NEW METHOD FOR NONINVASIVE QUANTIFICATION OF VALVULAR REGURGITATION BASED ON CONSERVATION OF MOMENTUM - INVITRO VALIDATION [J].
CAPE, EG ;
SKOUFIS, EG ;
WEYMAN, AE ;
YOGANATHAN, AP ;
LEVINE, RA .
CIRCULATION, 1989, 79 (06) :1343-1353
[4]   QUANTIFICATION OF REGURGITANT FLOW-THROUGH BILEAFLET HEART-VALVE PROSTHESES - THEORETICAL AND IN-VITRO STUDIES [J].
CAPE, EG ;
NANDA, NC ;
YOGANATHAN, AP .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (06) :461-468
[5]   Three-dimensional color Doppler: A new approach for quantitative assessment of mitral regurgitant jets [J].
De Simone, R ;
Glombitza, G ;
Vahl, CF ;
Albers, J ;
Meinzer, HP ;
Hagl, S .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (03) :173-185
[6]   Three-dimensional color Doppler: A clinical study in patients with mitral regurgitation [J].
De Simone, R ;
Glombitza, G ;
Vahl, CF ;
Albers, J ;
Meinzer, HP ;
Hagl, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) :1646-1654
[7]   Assessment of mitral regurgitant jets by three-dimensional color Doppler [J].
De Simone, R ;
Glombitza, G ;
Vahl, CF ;
Albers, J ;
Meinzer, HP ;
Hagl, S .
ANNALS OF THORACIC SURGERY, 1999, 67 (02) :494-499
[8]   Three-dimensional color Doppler for assessing mitral regurgitation during valvuloplasty [J].
De Simone, R ;
Glombitza, G ;
Vahl, CF ;
Albers, J ;
Meinzer, HP ;
Hagl, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (02) :127-133
[9]   INTRAMACHINE AND INTERMACHINE VARIABILITY IN TRANSESOPHAGEAL COLOR DOPPLER IMAGES OF PULSATILE JETS IN-VITRO STUDIES [J].
FAN, PH ;
ANAYIOTOS, A ;
NANDA, NC ;
YOGANATHAN, AP ;
CAPE, EG .
CIRCULATION, 1994, 89 (05) :2141-2149
[10]  
FENSTER A, 1995, Patent No. 5454371