Real-time dose-guidance in radiotherapy: Proof of principle

被引:10
|
作者
Muurholm, Casper Gammelmark [1 ]
Ravkilde, Thomas [2 ]
Skouboe, Simon [3 ]
Worm, Esben [2 ]
Hansen, Rune [2 ]
Hoyer, Morten [3 ,4 ]
Keall, Paul J. [5 ]
Poulsen, Per R. [1 ,3 ,4 ]
机构
[1] Aarhus Univ Hosp, Dept Oncol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Dept Med Phys, Aarhus, Denmark
[3] Aarhus Univ Hosp, Danish Ctr Particle Therapy, Aarhus, Denmark
[4] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[5] Univ Sydney, ACRF Image Inst 10, Sydney, NSW, Australia
关键词
Dose-guidance; Real-time motion management; Stereotactic body radiotherapy; GUIDED RADIOTHERAPY; RECONSTRUCTION; RECALCULATION; THERAPY; MOTION;
D O I
10.1016/j.radonc.2021.09.024
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The outcome of radiotherapy is a direct consequence of the dose delivered to the patient. Yet image-guidance and motion management to date focus on geometrical considerations as a practical sur-rogate for dose. Here, we propose real-time dose-guidance realized through continuous motion-including dose reconstructions and demonstrate this new concept in simulated liver stereotactic body radiotherapy (SBRT) delivery. Materials and methods: During simulated liver SBRT delivery, in-house developed software performed real-time motion-including reconstruction of the tumor dose delivered so far and continuously predicted the remaining fraction tumor dose. The total fraction dose was estimated as the sum of the delivered and predicted doses, both with and without the emulated couch correction that maximized the predicted final CTV D95% (minimum dose to 95% of the clinical target volume). Dose-guided treatments were simulated for 15 liver SBRT patients previously treated with tumor motion monitoring, using both sinusoidal tumor motion and the actual patient-measured motion. A dose-guided couch correction was triggered if it improved the predicted final CTV D95% with 3, 4 or 5 %-points. The final CTV D95% of the dose-guidance strategy was compared with simulated treatments using geometry guided couch corrections (Wilcoxon signed-rank test). Results: Compared to geometry guidance, dose-guided couch corrections improved the median CTV D95% with 0.5-1.5 %-points (p < 0.01) for sinusoidal motions and with 0.9 %-points (p < 0.01, 3 %-points trigger threshold), 0.5 %-points (p = 0.03, 4 %-points threshold) and 1.2 %-points (p = 0.09, 5 %-points threshold) for patient-measured tumor motion. Conclusion: Real-time dose-guidance was proposed and demonstrated to be superior to geometrical adaptation in liver SBRT simulations. (c) 2021 The Authors. Published by Elsevier B.V. Radiotherapy and Oncology 164 (2021) 175-182 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [31] Technical note: real-time web-based wireless visual guidance system for radiotherapy
    Danny Lee
    Siyong Kim
    Jatinder R. Palta
    Taeho Kim
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 463 - 469
  • [32] Real-time Proof of Violation for Cloud Storage
    Hwang, Gwan-Hwan
    Huang, Wei-Sian
    Peng, Jenn-Zjone
    2014 IEEE 6TH INTERNATIONAL CONFERENCE ON CLOUD COMPUTING TECHNOLOGY AND SCIENCE (CLOUDCOM), 2014, : 394 - 399
  • [33] Effectiveness of a Real-Time Parking Guidance System
    Sharma, Deepak K.
    Parr, Scott
    Kara, Aycan
    CONSTRUCTION RESEARCH CONGRESS 2022: COMPUTER APPLICATIONS, AUTOMATION, AND DATA ANALYTICS, 2022, : 502 - 510
  • [34] Real-time MRI Guidance of Cardiac Interventions
    Campbell-Washburn, Adrienne E.
    Tavallaei, Mohammad A.
    Pop, Mihaela
    Grant, Elena K.
    Chubb, Henry
    Rhode, Kawal
    Wright, Graham A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (04) : 935 - 950
  • [35] Real-time sentinel lymph node biopsy guidance using combined ultrasound, photoacoustic, fluorescence imaging: in vivo proof-of-principle and validation with nodal obstruction
    Kang, Jeeun
    Chang, Jin Ho
    Kim, Sun Mi
    Lee, Hak Jong
    Kim, Haemin
    Wilson, Brian C.
    Song, Tai-Kyong
    SCIENTIFIC REPORTS, 2017, 7
  • [36] Real-time sentinel lymph node biopsy guidance using combined ultrasound, photoacoustic, fluorescence imaging: in vivo proof-of-principle and validation with nodal obstruction
    Jeeun Kang
    Jin Ho Chang
    Sun Mi Kim
    Hak Jong Lee
    Haemin Kim
    Brian C. Wilson
    Tai-Kyong Song
    Scientific Reports, 7
  • [37] A Simulation Study on Real-Time Parking Guidance
    Xu, Man
    Zhang, Zuo
    Wan, Yi
    Li, Li
    2014 IEEE 17TH INTERNATIONAL CONFERENCE ON INTELLIGENT TRANSPORTATION SYSTEMS (ITSC), 2014, : 2269 - 2270
  • [38] Real-time tomosynthesis for radiation therapy guidance
    Hsieh, Scott S.
    Ng, Lydia W.
    MEDICAL PHYSICS, 2017, 44 (11) : 5584 - 5595
  • [39] REAL-TIME OPTIMAL GUIDANCE FOR ORBITAL MANEUVERING
    COHEN, AO
    BROWN, KR
    AIAA JOURNAL, 1973, 11 (09) : 1266 - 1272
  • [40] CYBERKNIFE: IMAGE GUIDANCE AND REAL-TIME TRACKING
    Hoogeman, M.
    Nuyttens, J.
    Seppenwoolde, Y.
    Levendag, P.
    Heijmen, B.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 (09) : 627 - 627