Effect of phenols on the potentiometric response of a nitrate-ion-selective electrode

被引:2
作者
Cabrera, WJ
Urzúa, M
Ríos, HE
机构
[1] Univ Chile, Fac Ciencias, Dept Quim, Santiago, Chile
[2] Univ Arturo Prat, Dept Quim, Iquique, Chile
关键词
nitrate; ion-selective electrodes; phenols effect; cation-pi interaction;
D O I
10.1016/S0021-9797(03)00486-7
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The effect of phenols containing different electron-withdrawing substituents on the potentiometric responses of several liquid PVC membranes containing the complex trioctylmethylammonium-nitrate, TOMA(+)NO(3)(-), is analyzed. The results make it possible to separate these phenols into two groups; those phenols containing electron-releasing groups, which produce almost Nernstian slopes, and those containing electron-withdrawing substituents, which generate sub-Nernstian slopes. The highly negative standard free energy of transfer of the aryl phenolic group from water to a cationic polar head suggests that these phenols are mainly located in the membrane phase associated with TOMA(+) via a cation-pi interaction. It seems that the strength of this interaction, and hence of the nitrate dissociation, is affected by the presence of phenols in an extension which correlates well with the kind of phenol present in these membranes and, consequently, with the type of their potentiometric responses. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:44 / 48
页数:5
相关论文
共 50 条
  • [41] SURFACE STUDIES OF ION-SELECTIVE ELECTRODE MEMBRANES
    CATTRALL, RW
    DEMARCO, R
    SELECTIVE ELECTRODE REVIEWS, 1992, 14 (02): : 169 - 193
  • [42] Halide ion-selective electrode array calibration
    Baret, M
    Massart, DL
    Fabry, P
    Menardo, C
    Conesa, F
    TALANTA, 1999, 50 (03) : 541 - 558
  • [43] Potentiometric response of liquid membrane electrode incorporated with macrocyclic polyamine towards benzoate
    Bulgariu, L
    Radecka, H
    Pietraszkiewiez, M
    Pietraszkiewicz, O
    ANALYTICAL LETTERS, 2003, 36 (07) : 1325 - 1334
  • [44] POTENTIOMETRIC ION-SELECTIVE AND BIOSELECTIVE ELECTRODES BASED ON ASYMMETRIC POLYURETHANE MEMBRANES
    LIU, D
    MEYERHOFF, ME
    GOLDBERG, HD
    BROWN, RB
    ANALYTICA CHIMICA ACTA, 1993, 274 (01) : 37 - 46
  • [45] Serum/plasma potassium monitoring using potentiometric point-of-care microanalyzers with improved ion selective electrodes
    Calvo-Lopez, Antonio
    Arasa-Puig, Eva
    Alonso-Chamarro, Julian
    Puyol, Mar
    TALANTA, 2023, 253
  • [46] Nitrate-selective electrode based on a cyclic bis-thiourea ionophore
    Watts, Amanda S.
    Gavalas, Vasilis G.
    Cammers, Arthur
    Andrada, Pilar Sanchez
    Alajarin, Mateo
    Bachas, Leonidas G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (01) : 200 - 207
  • [47] Characterization of a Silver Modified PVCAc Electrode and Its Application as a Ag(I)-Selective Potentiometric Sensor
    Sejmanovic, D. M.
    Petkovic, B. B.
    Budimir, M. V.
    Sovilj, S. P.
    Jovanovic, V. M.
    ELECTROANALYSIS, 2011, 23 (08) : 1849 - 1855
  • [48] All-Solid-State Potentiometric Sensor Based on Graphene Oxide as Ion-to-Electron Transducer for Nitrate Detection in Water Samples
    Gil, Renato L.
    Rodriguez-Lorenzo, Laura
    Espina, Begona
    Queiros, Raquel B.
    CHEMOSENSORS, 2024, 12 (06)
  • [49] Anion-selective light-addressable potentiometric sensors (LAPS) for the determination of nitrate and sulphate ions
    Mourzina, YG
    Ermolenko, YE
    Yoshinobu, T
    Vlasov, Y
    Iwasaki, H
    Schöning, MJ
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3): : 32 - 38
  • [50] Application of mathematical models and genetic algorithm to simulate the response characteristics of an ion selective electrode array for system recalibration
    Wang, Liang
    Yang, Die
    Lamb, Dane
    Chen, Zuliang
    Lesniewski, Peter J.
    Megharaj, Mallavarapu
    Naidu, Ravendra
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 144 : 24 - 30