Experimental study on the amplitude characteristics and propagation velocity of dynamic pressure wave for the leakage of gas-liquid two-phase intermittent flow in pipelines

被引:11
作者
Fang Liping [1 ]
Meng Lingya [1 ]
Liu Cuiwei [1 ]
Li Yuxing [1 ]
机构
[1] China Univ Petr, Shandong Prov Key Lab Oil & Gas Storage & Transpo, Qingdao Key Lab Circle Sea Oil & Gas Storage & Tr, Qingdao 266580, Shandong, Peoples R China
基金
美国国家科学基金会;
关键词
Slug flow leakage; Cavitation number; Dynamic pressure; Gas-liquid two-phase pipeline;
D O I
10.1016/j.ijpvp.2021.104457
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Intermittent flow is one of the most complex flow patterns in gas-liquid two-phase flow in pipelines. The leakage of pipeline intermittent flow poses a threat to the operating safety. In order to improve the application of acoustic method to gas-liquid two-phase leakage detection, the amplitude characteristics and propagation velocity of dynamic pressure wave of intermittent flow for gas-liquid two-phase pipeline leakage were investigated. Experiments with conditions of superficial liquid velocity (v(sL)) from 0.57 m/s to 1.06 m/s, superficial gas velocity (v(SG)) from 0.3 m/s to 4.47 m/s, leakage aperture from 4 mm to 9 mm were carried out, and the characteristics were studied by time-domain analysis, frequency-domain analysis and time-frequency analysis. The propagation velocity formula of dynamic pressure wave in two-phase medium was fitted based on Levenberg-Marquardt algorithm, and the propagation velocity of straight pipe and elbow pipe was discussed. The experimental results indicate that the peak-to-peak value of dynamic pressure wave measured by sensor within 4.25 m increases during top or mid sustained leakage when leak aperture is larger than 4 mm in elongated bubble flow and 6 mm in slug flow. The amplitude of sustained leakage dynamic pressure increases as gas flow rate increases. The low frequency energy of signal increases immediately when leakage occurs, the energy of signal mainly concentrates at 0-15 Hz, the frequency amplitude of sustained leakage signal is much higher than normal flow signal and leak occur signal. As the gas volume fraction increases from 0.23 to 0.75, the dynamic pressure propagation velocity decreases from 33.13 m/s to 26.5 m/s and then increases from 26.5 m/s to 66.25 m/s. The propagation velocity increases when it flows through an elbow pipe section. The results are meaningful for further study of two-phase pipeline slug flow leakage detection and location.
引用
收藏
页数:10
相关论文
共 30 条
  • [1] Baptista R.M., 2002, 2002 4 INT PIPELINE
  • [2] Chronic leak detection for single and multiphase flow: A critical review on onshore and offshore subsea and arctic conditions
    Behari, Niresh
    Sheriff, M. Ziyan
    Rahman, Mohammad Azizur
    Nounou, Mohamed
    Hassan, Ibrahim
    Nounou, Hazem
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2020, 81 (81)
  • [3] Cuiwei L., 2014, J VIB SHOCK, V33, P42
  • [4] 10 YEARS OF EXPERIENCE WITH LEAK DETECTION BY ACOUSTIC-SIGNAL ANALYSIS
    FUCHS, HV
    RIEHLE, R
    [J]. APPLIED ACOUSTICS, 1991, 33 (01) : 1 - 19
  • [5] Hu Q., 2019, RES EXPLOR LAB, V38, P159
  • [6] Ji J., SCI TECHNOL ENG, V21, P01
  • [7] Ji J., 2018, OIL GAS STORAGE T, V37, P493
  • [8] Flow around a corner in the water impact problem
    Krechetnikov, R.
    [J]. PHYSICS OF FLUIDS, 2014, 26 (07)
  • [9] Li Yuxing F.S, 2010, OILGAS WATER MULTIPH
  • [10] Lingya M., 2013, J CHINA U PETROLEUM, V37, P124