An Experimental Study of Laser in situ Fenestration of Current Aortic Endografts

被引:50
作者
Jayet, J. [1 ,2 ,3 ]
Heim, F. [3 ,4 ]
Coggia, M. [1 ,2 ]
Chakfe, N. [4 ,5 ]
Coscas, R. [1 ,2 ,6 ]
机构
[1] Ambroise Pare Univ Hosp, AP HP, Dept Vasc Surg, Boulogne, France
[2] Univ Versailles St Quentin En Yvelines, Fac Med Paris Ile France Ouest, UFR Sci Sante Simone Veil, Montigny Le Bretonneux, France
[3] Grp Europeen Rech Protheses Appl Chirurg Vasc GEP, Strasbourg, France
[4] Lab Phys & Mecan Text, Mulhouse, France
[5] Univ Strasbourg, Hop Univ Strasbourg, Dept Vasc Surg & Kidney Transplantat, Strasbourg, France
[6] Versailles St Quentin En Yvelines Univ, Paris Saclay Univ, Paul Brousse Hosp, UMR 1018,Inserm Paris11,CESP, Villejuif, France
关键词
Biomechanical testing; Endovascular; Laser in situ fenestration; Textile; Thoraco-abdominal aneurysm; STENT-GRAFTS; ANEURYSMS; PUNCTURE; CHIMNEY; FATIGUE; REPAIR;
D O I
10.1016/j.ejvs.2018.03.016
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective/Background: Laser in situ fenestration (LISF) is emerging as an immediately available alternative in the endovascular treatment of complex aortic aneurysm. However, its biomechanical features remain poorly understood. The aim of this study was to experimentally evaluate textile damage secondary to LISF and to compare LISF with mechanical in situ fenestration (MISF). Methods: An in vitro study evaluated the damage created by LISF on endograft fabrics versus MISF using a needle. Five different models of commercially available aortic endografts were used (32 samples of polyethylene terephthalate and expanded polytetrafluoroethylene fabrics). Tensile strength tests were performed on the fabrics before and after in situ fenestration, to determine the loss of mechanical strength. Integral water permeability tests at the stente-fenestration interface evaluated the watertightness of junctions. Stability of the connection was assessed with a fatigue bench test flexing the branch on the fenestration. In a second step, an in vivo study evaluating LISF in sheep was conducted. Results: Resulting holes had circular and cauterised edges following LISF, whereas fabric filaments were pushed aside after MISF. Tensile tests demonstrated a 34% and a 27% mechanical resistance loss after LISF (p = .004) and MISF (p = .001) compared with non-fenestrated samples. A non-significant global decrease of 7% in mechanical resistance was found following LISF compared with MISF (p = .520). Water permeability tests highlighted that leak rates were higher following LISF than with MISF with regard to multifilament specimens (p < .05). Fatigue tests induced modification of the morphology of fenestrations. The surface area of the fenestration was increased for all samples after 170,000 cycles. Regarding the in vivo study, 14 LISF were performed in 12 sheep with a technical success rate of 88%. Conclusion: This study demonstrates that both LISF and MISF create substantial damage to all available endograft fabrics. Until comparisons with reinforced fenestrations are performed, LISF and MISF should not be used outside investigational studies. (C) 2018 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 25 条
[1]   Experimental Evaluation of Complete Endovascular Arch Reconstruction by In Situ Retrograde Fenestration [J].
Canaud, Ludovic ;
Faure, Elsa Madeleine ;
Branchereau, Pascal ;
Ozdemir, Baris Ata ;
Marty-Ane, Charles ;
Alric, Pierre .
ANNALS OF THORACIC SURGERY, 2014, 98 (06) :2086-2091
[2]   Influence of the textile structure on the degradation of explanted aortic endoprostheses [J].
Chakfé, N ;
Dieval, F ;
Riepe, G ;
Mathieu, D ;
Zbali, I ;
Thaveau, F ;
Heintz, C ;
Kretz, JG ;
Durand, B .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2004, 27 (01) :33-41
[3]   Early Results of Physician Modified Fenestrated Stent Grafts for the Treatment of Thoraco-abdominal Aortic Aneurysms [J].
Cochennec, F. ;
Kobeiter, H. ;
Gohel, M. ;
Leopardi, M. ;
Raux, M. ;
Majewski, M. ;
Desgranges, P. ;
Allaire, E. ;
Becquemin, J. P. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 50 (05) :583-592
[4]   In Situ Fenestration Through the Contralateral Iliac Artery to Convert an Aortouni-iliac Into a Bifurcated Endograft [J].
Coscas, Raphael ;
Glorion, Matthieu ;
Javerliat, Isabelle ;
Goeau-Brissonniere, Olivier ;
Coggia, Marc .
JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (03) :421-425
[5]   Technical aspects, current indications, and results of chimney grafts for juxtarenal aortic aneurysms [J].
Coscas, Raphael ;
Kobeiter, Hicham ;
Desgranges, Pascal ;
Becquemin, Jean-Pierre .
JOURNAL OF VASCULAR SURGERY, 2011, 53 (06) :1520-1527
[6]   Physician-Modified C3 Excluder Endograft as the Preferred Solution to Treat a Juxtarenal Para-Anastomotic Aneurysm [J].
Couture, Thibault ;
Coscas, Raphael ;
Lamas, Henri ;
Mlynski, Amelie ;
Javerliat, Isabelle ;
Goeau-Brissonniere, Olivier ;
Coggia, Marc .
ANNALS OF VASCULAR SURGERY, 2017, 39 :287.e1-287.e5
[7]   Graft Durability and Fatigue after In Situ Fenestration of Endovascular Stent Grafts Using Radiofrequency Puncture and Balloon Dilatation [J].
Eadie, L. A. ;
Soulez, G. ;
King, M. W. ;
Tse, L. W. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (05) :501-508
[8]   A Comprehensive Review of In Situ Fenestration of Aortic Endografts [J].
Glorion, M. ;
Coscas, R. ;
McWilliams, R. G. ;
Javerliat, I. ;
Goeau-Brissonniere, O. ;
Coggia, M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 52 (06) :787-800
[9]  
Hartley D., 2005, Patent No. [2005/034808, 2005034808]
[10]  
Hearle JWS, 1969, YARNS FABR, VI