A Portable Wearable Tele-ECG Monitoring System

被引:86
作者
Ozkan, Haydar [1 ]
Ozhan, Orhan [2 ]
Karadana, Yasemin [1 ]
Gulcu, Muhammed [3 ]
Macit, Samet [3 ]
Husain, Fasahath [4 ]
机构
[1] Fatih Sultan Mehmet Vakif Univ, Dept Biomed Engn, TR-34445 Istanbul, Turkey
[2] Fatih Sultan Mehmet Vakif Univ, Dept Elect & Elect Engn, TR-34445 Istanbul, Turkey
[3] Fatih Sultan Mehmet Vakif Univ, Dept Comp Engn, TR-34445 Istanbul, Turkey
[4] US Tech Solut Inc, Edison, NJ 08837 USA
关键词
Electrocardiography; Biomedical monitoring; Monitoring; Electrodes; Heart rate; Medical services; Servers; Bluetooth low energy (BLE); ECG telemonitoring; healthcare; Internet of Things (IoT); telehealth care; wearable monitoring system; wearable sensors; TEXTILE; ELECTRODES; ENERGY; SENSOR;
D O I
10.1109/TIM.2019.2895484
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a wearable Tele-ECG and heart rate (HR) monitoring system which has a novel architecture including a stretchable singlet redesigned with textile electrodes (TEs), textile threads, snap fasteners, Velcro, sponges, and an ECG circuit. In addition, a Bluetooth low energy (BLE), a smartphone, a server, and a web page have been added to the system for remote monitoring. The TE can be attached to and removed from the singlet by a Velcro, which allows the user to dry-clean the TE easily for long-term use. A new holter-based ECG system has been designed to evaluate the TE-based ECG system and the average correlation between the recorded ECG signals is obtained as 99.23. A filtered digital signal, with a high signal-to-noise ratio of 45.62 dB, is transmitted to the smartphone via BLE. The ECG signal is plotted, the HR is calculated with 1.83 mean absolute percentage error, and displayed. The data are sent to the server, allowing the patient's physician to analyze the signals in real time through the web page or the smartphone. If HR reaches beyond the normal range or user presses the "HELP" button on the smartphone screen, the physician is informed automatically by an short message service (SMS) with a location pin on the map. The battery lasts approximately 14 days and when it needs replacement, the system automatically alerts the users by an SMS and a flashing LED. This fast and uninterrupted telemonitoring system has the potential to improve the patient's life quality by providing a psychological reassurance.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 39 条
  • [1] Design and Characterization of Screen-Printed Textile Electrodes for ECG Monitoring
    Achilli, Andrea
    Bonfiglio, Annalisa
    Pani, Danilo
    [J]. IEEE SENSORS JOURNAL, 2018, 18 (10) : 4097 - 4107
  • [2] Andreou G., 2015, 2015 IEEE 20 C EM TE, P1, DOI DOI 10.1109/EHB.2015.7391547
  • [3] Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring
    Ankhili, Amale
    Tao, Xuyuan
    Cochrane, Cedric
    Coulon, David
    Koncar, Vladan
    [J]. MATERIALS, 2018, 11 (02):
  • [4] ECG Authentication for Mobile Devices
    Arteaga-Falconi, Juan Sebastian
    Al Osman, Hussein
    El Saddik, Abdulmotaleb
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (03) : 591 - 600
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Electrical performance of PEDOT: PSS-based textile electrodes for wearable ECG monitoring: a comparative study
    Castrillon, Reinel
    Perez, Jairo J.
    Andrade-Caicedo, Henry
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [7] Textile-based, contactless ECG monitoring for non-ICU clinical settings
    Chamadiya, B.
    Mankodiya, K.
    Wagner, M.
    Hofmann, U. G.
    [J]. JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2013, 4 (06) : 791 - 800
  • [8] Effect of pressure and padding on motion artifact of textile electrodes
    Comert, Alper
    Honkala, Markku
    Hyttinen, Jari
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [9] Crawford J., 2012, PRACTICAL ASPECTS EC
  • [10] Atrial activity extraction from single lead ECG recordings: Evaluation of two novel methods
    Dai, Huhe
    Jiang, Shouda
    Li, Ye
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (03) : 176 - 183