Consumer Grade Weather Stations for Wooden Structure Fire Risk Assessment

被引:5
作者
Log, Torgrim [1 ]
机构
[1] Western Norway Univ Appl Sci, Dept Fire Safety & HSE Engn, Gloa R&D, N-5528 Haugesund, Norway
关键词
relative humidity; consumer grade weather stations; calibration; winter fire risk;
D O I
10.3390/s18103244
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During January 2014, Norway experienced unusually cold and dry weather conditions leading to very low indoor relative humidity (RH) in inhabited (heated) wooden homes. The resulting dry wood played an important role in the two most severe accidental fires in Norway recorded since 1923. The present work describes testing of low cost consumer grade weather stations for recording temperature and relative humidity as a proxy for dry wood structural fire risk assessment. Calibration of the weather stations relative humidity (RH) sensors was done in an atmosphere stabilized by water saturated LiCl, MgCl2 and NaCl solutions, i.e., in the range 11% RH to 75% RH. When calibrated, the weather station results were well within +/- 3% RH. During the winter 2015/2016 weather stations were placed in the living room in eight wooden buildings. A period of significantly increased fire risk was identified in January 2016. The results from the outdoor sensors compared favorably with the readings from a local meteorological station, and showed some interesting details, such as higher ambient relative humidity for a home close to a large and comparably warmer sea surface. It was also revealed that a forecast predicting low humidity content gave results close to the observed outdoor weather station data, at least for the first 48 h forecast.
引用
收藏
页数:15
相关论文
共 20 条
  • [1] Benfield B., 2018, COMPANION VOLUME WEA
  • [2] Delage C., 2015, RAPPORT COMMISSAIRE
  • [3] HUMIDITY FIXED-POINTS OF BINARY SATURATED AQUEOUS-SOLUTIONS
    GREENSPAN, L
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1977, 81 (01): : 89 - 96
  • [4] Kraaijeveld A, 2016, P 10 INT FIR SCI ENG, P553
  • [5] Langelandsvik G.M., 2015, COMMUNICATION
  • [6] Measurement of Temperature and Relative Humidity with Polymer Optical Fiber Sensors Based on the Induced Stress-Optic Effect
    Leal-Junior, Arnaldo
    Frizera-Neto, Anselmo
    Marques, Carlos
    Pontes, Maria Jose
    [J]. SENSORS, 2018, 18 (03):
  • [7] High-Sensitivity and Low-Hysteresis Porous MIM-Type Capacitive Humidity Sensor Using Functional Polymer Mixed with TiO2 Microparticles
    Liu, Ming-Qing
    Wang, Cong
    Kim, Nam-Young
    [J]. SENSORS, 2017, 17 (02)
  • [8] Unmanaged heathland - A fire risk in subzero temperatures?
    Log, Torgrim
    Thuestad, Gunnar
    Velle, Liv Gun
    Khattri, Sanjay Kumar
    Kleppe, Gisle
    [J]. FIRE SAFETY JOURNAL, 2017, 90 : 62 - 71
  • [9] Cold Climate Fire Risk; A Case Study of the L'rdalsoyri Fire, January 2014
    Log, Torgrim
    [J]. FIRE TECHNOLOGY, 2016, 52 (06) : 1825 - 1843
  • [10] Water droplets evaporating on horizontal semi-infinite solids at room temperature
    Log, Torgrim
    [J]. APPLIED THERMAL ENGINEERING, 2016, 93 : 214 - 222