Monitoring and improving the effectiveness of surface cleaning and disinfection

被引:57
作者
Rutala, William A. [1 ,2 ]
Weber, David J. [1 ,2 ]
机构
[1] Univ North Carolina Hlth Care, Hosp Epidemiol, Chapel Hill, NC USA
[2] UNC Sch Med, Div Infect Dis, Chapel Hill, NC USA
关键词
Surface; disinfection; cleaning; HYDROGEN-PEROXIDE VAPOR; INTENSIVE-CARE-UNIT; RESISTANT STAPHYLOCOCCUS-AUREUS; CLOSTRIDIUM-DIFFICILE SPORES; HOSPITAL ROOM SURFACES; HIGH-TOUCH SURFACES; ENVIRONMENTAL CONTAMINATION; ADENOSINE-TRIPHOSPHATE; DECONTAMINATION; PATHOGENS;
D O I
10.1016/j.ajic.2015.10.039
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Disinfection of noncritical environmental surfaces and equipment is an essential component of an infection prevention program. Noncritical environmental surfaces and noncritical medical equipment surfaces may become contaminated with infectious agents and may contribute to cross-transmission by acquisition of transient hand carriage by health care personnel. Disinfection should render surfaces and equipment free of pathogens in sufficient numbers to prevent human disease (ie, hygienically clean). (C) 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E69 / E76
页数:8
相关论文
共 77 条
  • [1] Use of a daily disinfectant cleaner instead of a daily cleaner reduced hospital-acquired infection rates
    Alfa, Michelle J.
    Lo, Evelyn
    Olson, Nancy
    MacRae, Michelle
    Buelow-Smith, Louise
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2015, 43 (02) : 141 - 146
  • [2] Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels
    Alfa, Michelle J.
    Fatima, Iram
    Olson, Nancy
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (03) : 245 - 248
  • [3] Use of ATP bioluminescence for assessing the cleanliness of hospital surfaces: A review of the published literature (1990-2012)
    Amodio, Emanuele
    Dino, Claudia
    [J]. JOURNAL OF INFECTION AND PUBLIC HEALTH, 2014, 7 (02) : 92 - 98
  • [4] [Anonymous], 2009, Infection Control Today
  • [5] [Anonymous], 2008, Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008
  • [6] Clinical studies of the High-Intensity Narrow-Spectrum light Environmental Decontamination System (HINS-light EDS), for continuous disinfection in the burn unit inpatient and outpatient settings
    Bache, Sarah E.
    Maclean, Michelle
    MacGregor, Scott J.
    Anderson, John G.
    Gettinby, George
    Coia, John E.
    Taggart, Ian
    [J]. BURNS, 2012, 38 (01) : 69 - 76
  • [7] Environmental meticillin-resistant Staphylococcus aureus (MRSA) disinfection using dry-mist-generated hydrogen peroxide
    Bartels, M. D.
    Kristoffersen, K.
    Slotsbjerg, T.
    Rohde, S. M.
    Lundgren, B.
    Westh, H.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2008, 70 (01) : 35 - 41
  • [8] Bates CJ, 2005, J HOSP INFECT, V61, P364, DOI 10.1016/j.jhin.2005.05.003
  • [9] Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a Healthcare setting
    Boyce, John M.
    Havill, Nancy L.
    Otter, Jonathan A.
    McDonald, L. Clifford
    Adams, Nicholas M. T.
    Cooper, Timothea
    Thompson, Angela
    Wiggs, Lois
    Killgore, George
    Tauman, Allison
    Noble-Wang, Judith
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2008, 29 (08) : 723 - 729
  • [10] Environmental contamination makes an important contribution to hospital infection
    Boyce, John M.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2007, 65 : 50 - 54