Consistency of atomic data for the interpretation of beam emission spectra

被引:52
作者
Delabie, E. [6 ]
Brix, M. [1 ]
Giroud, C. [1 ]
Jaspers, R. J. E. [2 ]
Marchuk, O. [3 ]
O'Mullane, M. G. [4 ]
Ralchenko, Yu [5 ]
Surrey, E. [1 ]
von Hellermann, M. G. [6 ]
Zastrow, K. D. [1 ]
机构
[1] EURATOM CCFE Assoc, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
[2] Eindhoven Univ Technol, NL-5600 MB Eindhoven, Netherlands
[3] Forschungszentrum Julich, Assoc EURATOM FZJ, D-52425 Julich, Germany
[4] Univ Strathclyde, Dept Phys, Glasgow G4 0NG, Lanark, Scotland
[5] NIST, Atom Phys Div, Gaithersburg, MD 20899 USA
[6] EURATOM, FOM Inst Plasma Phys Rijnhuizen, NL-3430 BE Nieuwegein, Netherlands
基金
英国工程与自然科学研究理事会;
关键词
PROTON-HYDROGEN COLLISIONS; 1ST EXCITED-STATE; FUSION PLASMAS; POWER FRACTIONS; BARE IONS; IONIZATION; SPECTROSCOPY; TEXTOR; TOKAMAK; RECOMBINATION;
D O I
10.1088/0741-3335/52/12/125008
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Several collisional-radiative (CR) models (Anderson et al 2000 Plasma Phys. Control. Fusion 42 781-806, Hutchinson 2002 Plasma Phys. Control. Fusion 44 71-82, Marchuk et al 2008 Rev. Sci. Instrum. 79 10F532) have been developed to calculate the attenuation and the population of excited states of hydrogen or deuterium beams injected into tokamak plasmas. The datasets generated by these CR models are needed for the modelling of beam ion deposition and (excited) beam densities in current experiments, and the reliability of these data will be crucial to obtain helium ash densities on ITER combining charge exchange and beam emission spectroscopy. Good agreement between the different CR models for the neutral beam (NB) is found, if corrections to the fundamental cross sections are taken into account. First the H(alpha) and H(beta) beam emission spectra from JET are compared with the expected intensities. Second, the line ratios within the Stark multiplet are compared with the predictions of a sublevel resolved model. The measured intensity of the full multiplet is approximate to 30% lower than expected on the basis of beam attenuation codes and the updated beam emission rates, but apart from the atomic data this could also be due to the characterization of the NB path and line of sight integration and the absolute calibration of the optics. The modelled n = 3 to n = 4 population agrees very well with the ratio of the measured H(alpha) to H(beta) beam emission intensities.
引用
收藏
页数:17
相关论文
共 38 条
[1]   Neutral beam stopping and emission in fusion plasmas I: deuterium beams [J].
Anderson, H ;
von Hellermann, MG ;
Hoekstra, R ;
Horton, LD ;
Howman, AC ;
Konig, RWT ;
Martin, R ;
Olson, RE ;
Summers, HP .
PLASMA PHYSICS AND CONTROLLED FUSION, 2000, 42 (07) :781-806
[2]   THE DEDUCTION OF LOW-Z ION TEMPERATURE AND DENSITIES IN THE JET TOKAMAK USING CHARGE-EXCHANGE RECOMBINATION SPECTROSCOPY [J].
BOILEAU, A ;
VONHELLERMANN, M ;
HORTON, LD ;
SPENCE, J ;
SUMMERS, HP .
PLASMA PHYSICS AND CONTROLLED FUSION, 1989, 31 (05) :779-804
[3]   ENHANCEMENT OF THE NEUTRAL-BEAM STOPPING CROSS-SECTION IN FUSION PLASMAS DUE TO MULTISTEP COLLISION PROCESSES [J].
BOLEY, CD ;
JANEV, RK ;
POST, DE .
PHYSICAL REVIEW LETTERS, 1984, 52 (07) :534-537
[4]  
Bransden B. H., 1992, Charge Exchange and the Theory of Ion-Atom Collisions
[5]  
CIRIC D, 2002, 19 IEEE NPSS S FUS E
[6]   Measuring one-dimensional and two-dimensional impurity density profiles on TEXTOR using combined charge exchange-beam emission spectroscopy and ultrasoft x-ray tomography [J].
De Bock, M ;
Jakubowska, K ;
von Hellermann, M ;
Jaspers, R ;
Donné, AJH ;
Shmaenok, L .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :4155-4157
[7]  
EMIL Y, 2001, PHYS REV A, V65
[8]   DETERMINATION OF NEUTRAL-BEAM-POWER PROFILES - DIVERGENCES AND POWER FRACTIONS OF THE SPECIES FROM MEASUREMENTS INSIDE THE TORUS OF TEXTOR [J].
EURINGER, H ;
VERPLANCKE, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (09) :2996-2999
[9]   IONIZATION OF THE 1ST EXCITED-STATE OF HYDROGEN BY BARE IONS AT INTERMEDIATE AND HIGH VELOCITIES [J].
FAINSTEIN, PD ;
PONCE, VH ;
RIVAROLA, RD .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1990, 23 (09) :1481-1489
[10]   Impact of calibration technique on measurement accuracy for the JET core charge-exchange system [J].
Giroud, Carine ;
Meigs, A. G. ;
Negus, C. R. ;
Zastrow, K. -D. ;
Biewer, T. M. ;
Versloot, T. W. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)