Corrosion behaviour and biocompatibility of a new dental noble AuPdAgTi alloy

被引:3
作者
Raducanu, D. [2 ]
Cimpean, A. [3 ]
Vasilescu, E. [1 ]
Cojocaru, V. D. [2 ]
Cinca, I. [2 ]
Drob, P. [1 ]
Ivanescu, S. [4 ]
机构
[1] Inst Phys Chem Ilie Murgulescu, Bucharest 060021, Romania
[2] Univ Politehn Bucuresti, Bucharest 060042, Romania
[3] Univ Bucharest, Dept Biochem & Mol Biol, Bucharest 050095, Romania
[4] SC R& Consulting & Serv SRL, Bucharest 023761, Romania
来源
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION | 2010年 / 61卷 / 09期
关键词
GOLD ALLOY; TITANIUM; IMPLANT; STABILITY; TI; BIOMATERIALS; FIBROBLASTS; ULTRASOUND; CERAMICS; CELLS;
D O I
10.1002/maco.201005636
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aims of the study were to investigate the electrochemical response of a new dental Au-20Pd-10Ag-5Ti alloy in artificial Carter-Brugirard saliva and to assess its biocompatibility using gingival fibroblast culture. Electrochemical techniques of potentiodynamic and linear polarization were used. Also, the open circuit potentials and the corresponding open circuit potential gradients were monitored for 5000 exposure hours. The gingival fibroblast response to Au-20Pd-10Ag-5Ti alloy was estimated by LDH-cytotoxicity, MTT cell proliferation assays, the assessment of substrate-dependent changes in extracellular fibronectin network, cell morphology and actin cytoskeleton organization. The cyclic potentiodynamic curves of Au-20Pd-10Ag-5Ti alloy exhibited a passive behaviour with transpassive dissolution of silver, without pitting corrosion. Open circuit potentials were finally stable at noble values. Open circuit potential gradients have low values that could not generate galvanic or local corrosion. The new Au-20Pd-10Ag-5Ti alloy did not promote cell damage and alterations in cell adhesion and morphological features, exhibiting a good biocompatibility.
引用
收藏
页码:775 / 782
页数:8
相关论文
共 45 条
[41]   Corrosive properties of fluoride-containing odontologic gels against titanium [J].
ToumelinChemla, F ;
Rouelle, F ;
Burdairon, G .
JOURNAL OF DENTISTRY, 1996, 24 (1-2) :109-115
[42]   CLINICAL-PERFORMANCE OF MACHINED TITANIUM RESTORATIONS [J].
WALTER, M ;
BONING, K ;
REPPEL, PD .
JOURNAL OF DENTISTRY, 1994, 22 (06) :346-348
[43]  
Wataha J C, 1995, Int J Prosthodont, V8, P9
[44]   Dental materials: 1997 literature review [J].
Whitters, CJ ;
Strang, R ;
Brown, D ;
Clarke, RL ;
Curtis, RV ;
Hatton, PV ;
Ireland, AJ ;
Lloyd, CH ;
McCabe, JF ;
Nicholson, JW ;
Scrimgeour, SN ;
Setcos, JC ;
Sherriff, M ;
van Noort, R ;
Watts, DC ;
Wood, D .
JOURNAL OF DENTISTRY, 1999, 27 (06) :401-435
[45]  
YAMADA KM, 1989, FIBRONECTIN, P48