摘要
This paper presents a comparative study on performance of conventional PI controller and fuzzy controller on three phase, three wire voltage source inverter based shunt active filter that is used to compensate the harmonics currents drawn by non-linear loads in distribution systems. Hysteresis PWM method is used to generate the pulses to the switches used in active filter. The compensation is based on PLL method of fundamental current extraction. The nonlinear load taken into account is a three phase diode bridge rectifier.
引用
收藏
页码:40 / +
页数:3
相关论文
共 50 条
  • [41] Power Supply of Resistance Welding Machine as Shunt Active Power Filter
    Podnebennaya, Svetlana
    Burlaka, Vladimir
    Gulakov, Sergey
    2019 IEEE 2ND UKRAINE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (UKRCON-2019), 2019, : 295 - 298
  • [42] Simulation of Shunt Active Power Filter using Instantaneous Power Theory
    Mahajan, Vasundhara
    Agarwal, Pramod
    Gupta, Hari Om
    2012 IEEE FIFTH POWER INDIA CONFERENCE, 2012,
  • [43] Research on LCR Filter in the Link of Shunt Active Power Filter in Electrical Power System
    Zhang, Chenyu
    Zheng, Jianyong
    Mei, Jun
    ADVANCED RESEARCH ON MATERIAL ENGINEERING AND ELECTRICAL ENGINEERING, 2013, 676 : 273 - 276
  • [44] Type-2 Fuzzy Logic Controlled Three-level Shunt Active Power Filter for Power Quality Improvement
    Suresh, Dhanavath
    Singh, Saijan Pal
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (08) : 873 - 882
  • [45] Harmonic Suppression and Reactive Power Compensation of Shunt Active Power Filter
    Wei, Ping
    Chen, Houquan
    Cheng, Dengliang
    2009 THIRD INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL 1, PROCEEDINGS, 2009, : 386 - 390
  • [46] Shunt hybrid active power filter under nonideal voltage based on fuzzy logic controller
    Dey, Papan
    Mekhilef, Saad
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2016, 103 (09) : 1580 - 1592
  • [47] Improved Repetitive Controller for Active Power Filter
    Wang, Yifan
    Zheng, Hong
    Wang, Ruoyin
    Zhu, Wen
    2017 6TH INTERNATIONAL SYMPOSIUM ON ADVANCED CONTROL OF INDUSTRIAL PROCESSES (ADCONIP), 2017, : 571 - 576
  • [48] A Fixed Switching Frequency Adaptive Sliding Mode Controller for Shunt Active Power Filter System
    Mohapatra, Soumya Ranjan
    Ray, Pravat Kumar
    TENCON 2014 - 2014 IEEE REGION 10 CONFERENCE, 2014,
  • [49] Fuzzy Logic Controller Based Three Phase Shunt Active Power Filter for Harmonics Reduction
    Musa, S.
    Radzi, M. A. M.
    Hisham, H.
    Abdulwahab, N. I.
    2014 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2014, : 371 - 376
  • [50] Intelligent controlled shunt active power filter for voltage and current harmonic compensation in microgrid system
    Tan, Kuang-Hsiung
    Lin, Faa-Jeng
    Chen, Jun-Hao
    Chan, Yung-Ruei
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2018, 41 (04) : 269 - 285