This paper presents a comparative study on performance of conventional PI controller and fuzzy controller on three phase, three wire voltage source inverter based shunt active filter that is used to compensate the harmonics currents drawn by non-linear loads in distribution systems. Hysteresis PWM method is used to generate the pulses to the switches used in active filter. The compensation is based on PLL method of fundamental current extraction. The nonlinear load taken into account is a three phase diode bridge rectifier.
引用
收藏
页码:40 / +
页数:3
相关论文
共 50 条
  • [21] Fuzzy Logic Controlled Three-Phase Three-Wired Shunt Active Power Filter for Power Quality Improvement
    Gupta, N.
    Singh, S. P.
    Dubey, S. P.
    Palwalia, D. K.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (03): : 1118 - 1129
  • [22] Feedback Linearization Control of a Shunt Active Power Filter Using a Fuzzy Controller
    Li, Tianhua
    Fei, Juntao
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2013, 10
  • [23] Power Quality Improvement Based on Shunt Active Power Filter Connected to a Photovoltaic Array
    Belaidi, Rachid
    Fathi, Mohamed
    Larafi, Mohamed Mghezzi
    Kaci, Gunia Mohand
    Belaidi, Rachid
    Haddouche, A.
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 557 - 562
  • [24] A novel adaptive hysteresis band current controller for shunt active power filter
    Kale, M
    Ozdemir, E
    CCA 2003: PROCEEDINGS OF 2003 IEEE CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 2003, : 1118 - 1123
  • [25] Approximated fuzzy logic controlled shunt active power filter for improved power quality
    Singh, Rambir
    Singh, Asheesh K.
    Arya, Rakesh K.
    EXPERT SYSTEMS, 2013, 30 (02) : 152 - 161
  • [26] Comparison of Fuzzy Logic and Neuro Fuzzy Controller for Shunt Active Power Filter
    Pedapenki, Kishore Kumar
    Gupta, S. P.
    Pathak, Mukesh Kumar
    2015 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMMUNICATION NETWORKS (CICN), 2015, : 1247 - 1250
  • [27] Design of Single Input Fuzzy Logic Controller for Shunt Active Power Filter
    Suresh, Dhanavath
    Singh, Sajjan Pal
    IETE JOURNAL OF RESEARCH, 2015, 61 (05) : 500 - 509
  • [28] Simulation And Comparison Between Hybrid Active Power Filter And Shunt Active Power Filter
    Dobariya, D. R.
    Upadhyay, P. A.
    2015 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, SIGNALS, COMMUNICATION AND OPTIMIZATION (EESCO), 2015,
  • [29] PI and fuzzy logic controllers for shunt active power filter - A report
    Karuppanan, P.
    Mahapatra, Kamala Kanta
    ISA TRANSACTIONS, 2012, 51 (01) : 163 - 169
  • [30] Heterogeneous Active Power Filter Controller
    Firlit, Andrzej
    Kolek, Krzysztof
    Piatek, Krzysztof
    PROCEEDINGS OF 2017 INTERNATIONAL SYMPOSIUM ELMAR, 2017, : 241 - 244