Total-Ionization-Dose Radiation-Induced Noise Modeling and Analysis of a 2k x 2k 4T CMOS Active Pixel Sensor for Space Applications

被引:2
作者
Gao, Wu [1 ]
Wu, Mengshi [1 ]
Tang, Yin [1 ]
Liu, Yuan [1 ]
Wang, Zujun [2 ]
Chen, Wei [2 ]
Zhang, Yanning [1 ]
机构
[1] Northwestern Polytech Univ, Sch Comp Sci & Technol, Xian 710072, Shaanxi, Peoples R China
[2] Northwest Inst Nucl Technol, State Key Lab Intense Pulsed Radiat Simulat & Eff, Xian 710024, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
CMOS active pixel sensor; total ionizing dose (TID); dark current (DC); fixed pattern noise (FPN); equivalent noise charge (ENC); IMAGE SENSORS; IRRADIATION; PROTON;
D O I
10.1109/JSEN.2018.2860787
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents modeling techniques of total-ionization-dose (TID) radiation-induced noise characteristics including dark current (DC), fixed pattern noise (FPN), and equivalent noise charge (ENC) of a CMOS active pixel sensor (APS) for space applications. The noise models from theoretical derivation and experimental data analysis are discussed in detail according to the circuit structure of the CMOS APS based on 4-T transistor pixel topology followed by the column-level correlation double sampling and the column-level amplifier. From the simulation of the theoretical models, the amplitude of noise significantly increases with the increase of total dose, and a threshold dose of similar to 60 krad (Si) exists. When the total dose is below such threshold, DC, FPN, and ENC increase slowly. When the total dose exceeds the threshold value, these noise parameters increase substantially according to the exponential growth. To verify the proposed models, a gamma-ray radiation experiment using Co-60 source is performed on a commercial 2k x 2k CMOS APS chip in 180-nm CMOS technology from Vendor A. The noise performance of two CMOS APS devices at the dose rates of 50 and 10.6 rad(Si)/s has been measured. It shows that experimental results are in accordance with the rules of theoretical deduction. The dose threshold of the abovementioned three noise parameters is around 60 krad (Si). The TID-induced noise models can be applied to both the design of radiation-hardened CMOS APS and the construction of filtering algorithms in the post image processing.
引用
收藏
页码:8053 / 8063
页数:11
相关论文
共 19 条
[1]   Cobalt-60, Proton and Electron Irradiation of a Radiation-Hardened Active Pixel Sensor [J].
Beaumel, Matthieu ;
Herve, Dominique ;
Van Aken, Dirk .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) :2056-2065
[2]   Total dose and displacement damage effects in a radiation-hardened CMOS APS [J].
Bogaerts, J ;
Dierickx, B ;
Meynants, G ;
Uwaerts, D .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2003, 50 (01) :84-90
[3]   Temporal Readout Noise Analysis and Reduction Techniques for Low-Light CMOS Image Sensors [J].
Boukhayma, Assim ;
Peizerat, Arnaud ;
Enz, Christian .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2016, 63 (01) :72-78
[4]  
Boukhayma A, 2014, IEEE INT NEW CIRC, P241, DOI 10.1109/NEWCAS.2014.6934028
[5]   Reliability investigations of 850 nm silicon photodiodes under proton irradiation for space applications [J].
Bourqui, M. L. ;
Bechou, L. ;
Gilard, O. ;
Deshayes, Y. ;
Del Vecchio, P. ;
How, L. S. ;
Rosala, F. ;
Ousten, Y. ;
Touboul, A. .
MICROELECTRONICS RELIABILITY, 2008, 48 (8-9) :1202-1207
[6]   Study of radiation-induced leakage current between adjacent devices in a CMOS integrated circuit [J].
Ding Lili ;
Guo Hongxia ;
Chen Wei ;
Fan Ruyu .
JOURNAL OF SEMICONDUCTORS, 2012, 33 (06)
[7]   Total Ionizing Dose Effects in MOS and Low-Dose-Rate-Sensitive Linear-Bipolar Devices [J].
Fleetwood, Daniel M. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) :1706-1730
[8]  
He B. - P., 2015, CHINESE PHYS C, V39, P71
[9]  
[He Baoping 何宝平], 2016, [Journal of Semiconductors, 半导体学报], V37, P49
[10]  
Jin H., 2012, THESIS, P34