Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study

被引:80
作者
Kalra, MK
Wittram, C
Maher, MM
Sharma, A
Avinash, GB
Karau, K
Toth, TL
Halpern, E
Saini, S
Shepard, JA
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] GE Co, Med Syst, Waukesha, WI USA
关键词
computed tomography (CT); radiation exposure; filters; radiographic; thorax; CT;
D O I
10.1148/radiol.2281020606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Effect of noise reduction filters on chest computed tomographic (CT) images acquired with 50% radiation dose reduction was evaluated. Two sets of images were acquired with multi-detector row CT at standard (220-280 mA) and 50% reduced (110-140 mA) tube current at the level of the carina. After postprocessing with six noise reduction filters, images were compared with baseline standard-dose images for noise, sharpness, and contrast in lungs, mediastinum, and chest wall. Quantitative image noise was measured in descending thoracic aorta. Modulation transfer functions were calculated from CT images of 50-mum wire. Noise reduction filters reduced image noise on low-radiation-dose chest CT images, with some compromise in image sharpness and contrast assessed qualitatively, and slightly altered modulation transfer function at higher spatial frequencies. (C) RSNA, 2003.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 32 条
  • [1] OPTIMAL PROCESSING OF COMPUTED TOMOGRAPHY IMAGES USING EXPERIMENTALLY MEASURED NOISE PROPERTIES
    ALVAREZ, RE
    STONESTROM, JP
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (01) : 77 - 84
  • [2] The Society of Computed Body Tomography and Magnetic Resonance Imaging - Research in CT and MR imaging: 2000 and beyond
    Balfe, DM
    Ehman, RL
    [J]. RADIOLOGY, 1998, 207 (03) : 561 - 564
  • [3] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [4] Population exposure to diagnostic use of ionizing radiation in the Netherlands
    Brugmans, MJP
    Buijs, WCAM
    Geleijns, J
    Lembrechts, J
    [J]. HEALTH PHYSICS, 2002, 82 (04): : 500 - 509
  • [5] Cohnen M, 2000, AM J NEURORADIOL, V21, P1654
  • [6] A practical approach to the first iteration in the optimization of radiation dose and image quality in CT: estimates of the collective dose savings achieved
    Crawley, MT
    Booth, A
    Wainwright, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (883) : 607 - 614
  • [7] Pulmonary nodules: Experimental and clinical studies at low-dose CT
    Diederich, S
    Lenzen, H
    Windmann, R
    Puskas, Z
    Yelbuz, TM
    Henneken, S
    Klaiber, T
    Eameri, M
    Roos, N
    Peters, PE
    [J]. RADIOLOGY, 1999, 213 (01) : 289 - 298
  • [8] ERGUN DL, 1994, P SOC PHOTO-OPT INS, V2167, P663, DOI 10.1117/12.175102
  • [9] System performance of multislice spiral computed tomography
    Fuchs, TOJ
    Kachelriess, M
    Kalender, WA
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2000, 19 (05): : 63 - 70