Evaluation of four mass spectrometric methods for the gas chromatographic analysis of polychlorinated n-alkanes

被引:48
|
作者
Zencak, Z
Borgen, A
Reth, M
Oehme, M
机构
[1] Univ Basel, CH-4057 Basel, Switzerland
[2] Norwegian Inst Air Res, Kjeller, Norway
关键词
polychlorinated n-alkanes; chlorinated paraffins; intercomparison; mass spectrometry;
D O I
10.1016/j.chroma.2004.09.098
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The suitability of four mass spectrometric methods for the gas chromatographic analysis of polychlorinated n-alkanes (PCAs, also called chlorinated paraffins) was evaluated and compared using spiked and fish liver samples. Electron ionization tandem mass spectrometry (EI-MS/MS) as well as electron capture negative ionization (ECNI) combined with low and high resolution mass spectrometry and CH4/CH2Cl2-negative ion chemical ionization (NICI) low resolution mass spectrometry were investigated. All methods showed an accuracy of < 21% for the analysis of spiked fish samples. However, the analysis of real samples showed deviations of up to 46% between the four mass spectrometric methods. The influence of the selected reference standard on quantification was also evaluated. The use of a quantification standard with a degree of chlorination deviating from that of the sample can result in differences of > 100% for the ECNI methods. EI-MS/MS and CH4/CH2Cl2-NICI led to errors of maximum 17% and 33%, respectively, independent from the degree of chlorination of the used reference standard. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 50 条
  • [41] GAS-CHROMATOGRAPHIC DETERMINATION AND GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC ANALYSIS OF CHLORAMPHENICOL, THIAMPHENICOL AND THEIR METABOLITES
    NAKAGAWA, T
    MASADA, M
    UNO, T
    JOURNAL OF CHROMATOGRAPHY, 1975, 111 (02): : 355 - 364
  • [42] The Influence of Temperature on the Gas Chromatographic Retention of n-Alkanes, Arenes, and Alkanols in a PLOT Capillary Column with Aerosil
    L. A. Onuchak
    I. A. Platonov
    P. V. Smirnov
    A. V. Didenko
    Russian Journal of Physical Chemistry A, Focus on Chemistry, 2008, 82 (4): : 643 - 646
  • [43] A comparison of a gas chromatographic with electron-capture detection and a gas chromatographic with mass spectrometric detection screening methods for the analysis of famoxadone in grapes and wines
    Abreu, SD
    Caboni, P
    Cabras, P
    Alves, A
    Garau, VL
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (02) : 362 - 367
  • [45] Gas chromatographic mass spectrometric calibration bias
    Troost, JR
    Olavesen, EY
    ANALYTICAL CHEMISTRY, 1996, 68 (04) : 708 - 711
  • [46] Gas chromatographic tandem mass spectrometric analysis of clenbuterol residues in faeces
    Batjoens, P
    Courtheyn, D
    DeBrabander, HF
    Vercammen, J
    DeWasch, K
    Logghe, M
    JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) : 133 - 139
  • [47] GAS-CHROMATOGRAPHIC AND MASS-SPECTROMETRIC ANALYSIS OF SILICON TETRABROMIDE
    AGLIULOV, NK
    ZUEVA, MV
    FESHCHENKO, IA
    FAERMAN, VI
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1975, 30 (09): : 1459 - 1462
  • [48] MASS-SPECTROMETRIC AND GAS-CHROMATOGRAPHIC ANALYSIS OF HYDROGEN IODIDE
    DUDOROV, VY
    AGLIULOV, NK
    FAERMAN, VI
    ZHURNAL ANALITICHESKOI KHIMII, 1974, 29 (02): : 361 - 364
  • [49] GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC ANALYSIS OF METHYLPHENIDATE (RITALIN) IN SERUM
    CHAN, YM
    SOLDIN, SJ
    SWANSON, JM
    DEBER, CM
    THIESSEN, JJ
    MACLEOD, S
    CLINICAL BIOCHEMISTRY, 1980, 13 (06) : 266 - 272
  • [50] GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC ANALYSIS OF METHAQUALONE, PHENDIMETRAZINE AND PHENMETRAZINE
    BOYD, PM
    MOSES, PJ
    BOWMAN, L
    SPECTROSCOPY LETTERS, 1974, 7 (4-5) : 223 - 227