Radio-frequency common-mode noise propagation model for power-line cable

被引:18
作者
See, KY [1 ]
So, PL [1 ]
Kamarul, A [1 ]
Gunawan, E [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Network Technol Res Ctr, Singapore 639798, Singapore
关键词
broadband communication; electromagnetic compatibility; electromagnetic interference; impedance measurement;
D O I
10.1109/TPWRD.2005.852268
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electromagnetic-interference (EMI) radiation from a power-line communications (PLC) network has been a major concern for the widespread use of broadband PLC technology. It is also well known that the dominant radiation mode of the, PLC network is common mode (CM) by nature. Therefore, for electromagnetic-compatibility planning purposes, knowledge of the CM noise propagation path of the power line in the frequency range of 1 to 30 MHz is essential to provide insight of EMI radiation emitted by the power line. Based on a two-current-probe measurement approach, the CM noise propagation model for a three-wire power-line cable can be derived and represented by an equivalent two-wire CM transmission line. The equivalent CM noise propagation model allows us to predict the CM noise current on the power line with reasonable accuracy. The model will serve as a valuable tool in the future to identify effective ways to suppress EMI radiation from the PLC network.
引用
收藏
页码:2443 / 2449
页数:7
相关论文
共 17 条
[1]  
[Anonymous], P INT S POW LIN COMM
[2]  
[Anonymous], 1997, INF TECHN EQ RAD DIS, V22
[3]  
ASANO K, 2004, P ISPLC C, P143
[4]   Electromagnetic field radiated from broadband signal transmission on power line carrier channels [J].
DAmore, M ;
Sarto, MS .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (02) :624-631
[5]  
DOSTERT K, 2000, P 15 INT WROCL S EMC, P98
[6]  
*FED COMM COMM, 1987, FCC METH MEAS RAD NO
[7]  
HENSEN C, 2001, P ISPLC C, P155
[8]   TECHNIQUE FOR MEASUREMENT OF POWERLINE IMPEDANCES IN THE FREQUENCY-RANGE FROM 500-KHZ TO 500-MHZ [J].
KWASNIOK, PJ ;
BUI, MD ;
KOZLOWSKI, AJ ;
STUCHLY, SS .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1993, 35 (01) :87-90
[9]   Indoor radiated emission associated with power line communication systems [J].
Marthe, E ;
Rachidi, F ;
Ianoz, M ;
Zweiacker, P .
2001 IEEE EMC INTERNATIONAL SYMPOSIUM, VOLS 1 AND 2, 2001, :517-520
[10]  
MUTO C, 2003, P ISPLC C, P67