Effect of neutron irradiation on dosimetric properties of TLD-600H (6LiF:Mg,Cu,P)

被引:6
作者
Romanyukha, A. [1 ]
Minniti, R. [2 ]
Moscovitch, M. [3 ]
Thompson, A. K. [2 ]
Trompier, F. [4 ]
Colle, R. [2 ]
Sucheta, A. [1 ]
Voss, S. P. [1 ]
Benevides, L. A. [1 ]
机构
[1] Naval Dosimetry Ctr, Bethesda, MD 20814 USA
[2] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[3] Georgetown Univ, Georgetown, DC USA
[4] Inst Radioprotect & Surete Nucl, Fontenay Aux Roses, France
关键词
Neutron dosimetry; TLD; Tritium; Albedo dosimetry; Lithium fluoride;
D O I
10.1016/j.radmeas.2011.06.066
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Ideally, dosimeters should measure the dose without their dosimetric properties being affected by the radiation type being measured. Industry-wide occupational radiation workers that can be potentially exposed to neutron radiation fields are routinely monitored by thermoluminescent (TLD) dosimeters. The neutron dose measured by these devices is obtained from the interaction products of thermal (slow) neutrons and Li-6. The number of alpha particle and H-3(-) ions (tritium) released in the (n, Li-6) reaction is proportional to the dose received by the dosimeter. It is a common practice to evaluate the neutron dose indirectly from these products. In this work we present for the first time direct evidence that the neutron exposure to LiF:Mg,Cu,P (TLD-600H) can have deleterious effects on the dosimetric properties of one of the most commonly utilized dosimeters in the world. The interstitial non-negligible tritium dose contribution to the dosimeter is a result of the beta decay of the tritium nuclei interstitially present in the material. If not accounted for the effect of this self irradiation can directly affect the measured occupational dose to workers. In order to estimate the significance of these effects, tritium dose buildup was measured in the TLD-600H irradiated to different neutron doses from a reactor and a Cf-252 source and then calculated in terms of a daily dose buildup rate. The effect of the self irradiation on these dosimeters resulting from tritium decay was extensively studied. The TLD dosimeters that were exposed to neutron doses show a significant dose buildup even after they have been annealed, i.e. even after the signal produced by the incident neutron dose is completely erased from the lower energy trap states of the dosimeter. The other discovered effect of neutron irradiation on TLD-600H is a significant loss in the detection sensitivity (up to 15%). Published by Elsevier Ltd.
引用
收藏
页码:1426 / 1431
页数:6
相关论文
共 10 条
[1]  
[Anonymous], 2009, N1311 ANSIHPS
[2]  
Burgkhardt B., 1982, Radiation Protection Dosimetry, V2, P105
[3]  
Burgkhardt B., 1982, Radiation Protection Dosimetry, V2, P221
[4]  
Cassata JR, 2002, RADIAT PROT DOSIM, V101, P27, DOI 10.1093/oxfordjournals.rpd.a005983
[5]  
DeWerd L. A., 1983, RADIAT PROT DOSIM, V6, P350
[6]  
HOROWITZ A, 1993, RADIAT PROT DOSIM, V47, P69
[7]   The application of LiF:Mg,Cu,P to large scale personnel dosimetry:: Current status and future directions [J].
Moscovitch, M. ;
John, T. J. St. ;
Cassata, J. R. ;
Blake, P. K. ;
Rotunda, J. E. ;
Ramlo, M. ;
Velbeck, K. J. ;
Luo, L. Z. .
RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) :248-254
[8]   EFFECT OF BACKGROUND RADIATION ON THE LOWER LIMIT OF DETECTION FOR EXTENDED DOSEMETER ISSUE PERIODS [J].
Romanyukha, Alex ;
King, David ;
Benevides, Luis A. .
RADIATION PROTECTION DOSIMETRY, 2008, 131 (02) :180-187
[9]   Technical aspects of the Naval Dosimetry Center quality assurance programme [J].
St John, T. J. ;
Cassata, J. R. ;
Blake, P. K. ;
Wallace, W. H. ;
Minniti, R. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :273-277
[10]  
TAYLOR BN, 1994, 1297 NATL I STAND TE