摘要
Purpose: To present a new 4D method that is designed to provide high spatial resolution MR angiograms at subsecond temporal resolution by combining different techniques of view sharing with parallel imaging at 3.0T. Materials and Methods: In the keyhole-based method, a central elliptical cylinder in k-space is repeated n times (keyhole) with a random acquisition (CENTRA), and followed by the readout of the periphery of k-space. 4D-MR angiography with CENTRA keyhole (4D-TRAK) was combined with parallel imaging (SENSE) and partial Fourier imaging. In total, a speed-up factor of 66.5 (6.25 [CENTRA keyhole) x 8 [SENSE] x 1.33 [partial Fourier imaging]) was achieved yielding a temporal resolution of 608 ms and a spatial resolution of (1.1 x 1.4 x 1.1) mm(3) with whole-brain coverage 4D-TRAK was applied to five patients and compared with digital subtraction angiography (DSA). Results: 4D-TRAK was successfully completed with an acceleration factor of 66.5 in all five patients. Sharp images were acquired without any artifacts possibly created by the transition of the central cylinder and the reference dataset. MRA findings were concordant with DSA. Conclusion: 4D time-resolved MRA with keyhole (4D-TRAK) is feasible using a combination of CENTRA, keyhole, and SENSE at 3.0T and allows for more than 60 times accelerated MRA with high spatial resolution.
引用
收藏
页码:1455 / 1460
页数:6
相关论文
共 35 条
[11]   New approach to 3D time-resolved angiography [J].
Madore, B ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :1022-1025
[12]   Combined time-resolved and high-spatial-resolution 3D MRA using an extended adaptive acquisition [J].
Mazaheri, Y ;
Carroll, TJ ;
Du, JA ;
Block, WF ;
Fain, SB ;
Hany, TF ;
Aagaard, BDL ;
Strother, CM ;
Mistretta, CA ;
Grist, TM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (03) :291-301
[13]   Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experience [J].
Meckel, S ;
Mekle, R ;
Taschner, C ;
Haller, S ;
Scheffler, K ;
Radue, EW ;
Wetzel, SG .
NEURORADIOLOGY, 2006, 48 (05) :291-299
[14]   Time-resolved, high-resolution contrast-enhanced MR angiography of dialysis shunts using the CENTRA keyhole technique with parallel imaging [J].
Mende, Katja A. ;
Froehlich, Johannes M. ;
von Weymarn, Constantin ;
Hoogeveen, Romhild ;
Kistler, Thomas ;
Zollikofer, Christoph L. ;
Wentz, Klaus U. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) :832-840
[15]   Two-dimensional thick-slice MR digital subtraction anglography in the assessment of small to medium-size intracranial arteriovenous malformations [J].
Mori, H ;
Aoki, S ;
Okubo, T ;
Hayashi, N ;
Masumoto, T ;
Yoshikawa, T ;
Tago, M ;
Shin, M ;
Kurita, H ;
Abe, O ;
Ohtomo, K .
NEURORADIOLOGY, 2003, 45 (01) :27-33
[16]   High spatial-resolution CE-MRA of the carotid circulation with parallel imaging - Comparison of image quality between 2 different acceleration factors at 3.0 Tesla [J].
Nael, K ;
Ruehm, SG ;
Michaely, HJ ;
Pope, W ;
Laub, G ;
Finn, JP ;
Villablanca, JP .
INVESTIGATIVE RADIOLOGY, 2006, 41 (04) :391-399
[17]   Brain arteriovenous malformations: measurement of nidal volume using a combination of static and dynamic magnetic resonance angiography techniques [J].
Nagaraja, S ;
Capener, D ;
Coley, S ;
Lee, K ;
Wilkinson, I ;
Kemeny, A ;
Griffiths, P .
NEURORADIOLOGY, 2005, 47 (05) :387-392
[18]  
Oesterle C, 2000, JMRI-J MAGN RESON IM, V11, P312, DOI 10.1002/(SICI)1522-2586(200003)11:3<312::AID-JMRI10>3.0.CO
[19]  
2-K
[20]   DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY [J].
PRINCE, MR ;
YUCEL, EK ;
KAUFMAN, JA ;
HARRISON, DC ;
GELLER, SC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06) :877-881