Total hCG tests

被引:33
作者
Cole, Laurence A. [1 ]
DuToit, Stephen [2 ]
Higgins, Trefor N. [3 ]
机构
[1] Univ New Mexico, Dept Obstet & Gynecol, USA hCG Reference Serv, Albuquerque, NM 87131 USA
[2] Waikato Hosp, Biochem Hlth Waikato Lab, Hamilton, New Zealand
[3] DynaLifeDX, Clin Chem, Edmonton, AB, Canada
关键词
hCG; Hyperglycosylated hCG; Pregnancy test; hCG test; HUMAN CHORIONIC-GONADOTROPIN; HETEROGENEITY; IMMUNOASSAYS; CARBOHYDRATE; PREGNANCY; ISOFORMS;
D O I
10.1016/j.cca.2011.08.006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: There are 12 types of automated total hCG tests sold today, the Abbott Architect, Abbott AxSym, the Beckman Access 2. Beckman DxI 800, the Ortho Vitros EciQ Roche Elecsys hCG + beta, Siemens ACS180, Siemens Centaur, Siemens Dimension, Siemens Immulite and Siemens Stratus, and the Tosoh A1A. All tests claim to be total hCG tests but do not define what total means. Total hCG test needs to detect all hCG variants in order to be used for all hCG test clinical applications. Here we assess this ability. Methods: Coded samples of pure hCG, nicked hCG, hyperglycosylated hCG, nicked hCG missing C-terminal peptide, nicked hyperglycosylated hCG, asialo hCG, hCG beta, nicked hCG beta and beta-core fragment were tested blindly in serum and urine at 10 independent laboratories. Results: While the Siemens Immulite total hCG test detected 8 of 9 hCG variant standards, other assays poorly detected important determinants such as nicked hCG missing the C-terminal peptide, beta-core fragment, hyperglycosylated hCG, nicked hCG, asialo hCG, and hCG beta. Four assay appropriately detected 4 of 9 variants, 2 assays detected 3 of 9, 4 assays detected 2 of 9 and 1 assay only appropriately detected 1 of 7 hCG variants. Discussion: Care is needed in selecting a total hCG test. The Siemens Immulite tests performed best at detecting all the hCG variants making it appropriate for all applications. Nine assays had limited applications, 3 of the assays were appropriate for advanced pregnancy testing only. (C) 2011 Published by Elsevier B.V.
引用
收藏
页码:2216 / 2222
页数:7
相关论文
共 19 条
[11]  
Cole LA, 2010, HUMAN CHORIONIC GONADOTROPIN (HCG), P49, DOI 10.1016/B978-0-12-384907-6.00005-0
[12]  
Cole LA, 2010, J REPROD MED, V55, P99
[13]   New discoveries on the biology and detection of human chorionic gonadotropin [J].
Cole, Laurence A. .
REPRODUCTIVE BIOLOGY AND ENDOCRINOLOGY, 2009, 7
[14]   Human chorionic gonadotropin testing for early pregnancy viability and complications [J].
Davies, S ;
Byrn, F ;
Cole, LA .
CLINICS IN LABORATORY MEDICINE, 2003, 23 (02) :257-+
[15]   Carbohydrate and peptide structure of the alpha -and beta-subunits of human chorionic gonadotropin from normal and aberrant pregnancy and choriocarcinoma [J].
Elliott, MM ;
Kardana, A ;
Lustbader, JW ;
Cole, LA .
ENDOCRINE, 1997, 7 (01) :15-32
[16]   THE HETEROGENEITY OF HUMAN CHORIONIC-GONADOTROPIN (HCG) .1. CHARACTERIZATION OF PEPTIDE HETEROGENEITY IN 13 INDIVIDUAL PREPARATIONS OF HCG [J].
KARDANA, A ;
ELLIOTT, MM ;
GAWINOWICZ, MA ;
BIRKEN, S ;
COLE, LA .
ENDOCRINOLOGY, 1991, 129 (03) :1541-1550
[17]   Differential expression of human chorionic gonadotropin (hCG) glycosylation isoforms in failing and continuing pregnancies: preliminary characterization of the hyperglycosylated hCG epitope [J].
Kovalevskaya, G ;
Birken, S ;
Kakuma, T ;
Ozaki, N ;
Sauer, M ;
Lindheim, S ;
Cohen, M ;
Kelly, A ;
Schlatterer, J ;
O'Connor, JF .
JOURNAL OF ENDOCRINOLOGY, 2002, 172 (03) :497-506
[18]   Differences in Recognition of the 1st WHO International Reference Reagents for hCG-Related Isoforms by Diagnostic Immunoassays for Human Chorionic Gonadotropin [J].
Sturgeon, Catharine M. ;
Berger, Peter ;
Bidart, Jean-Michel ;
Birken, Steven ;
Burns, Chris ;
Norman, Robert J. ;
Stenman, Ulf-Hakan .
CLINICAL CHEMISTRY, 2009, 55 (08) :1484-1491
[19]   The analytical specificity of human chorionic gonadotropin assays determined using WHO International Reference Reagents [J].
Whittington, JoDell ;
Fantz, Corinne R. ;
Gronowski, Ann M. ;
McCudden, Christopher ;
Mullins, Richard ;
Sokoll, Lori ;
Wiley, Carmen ;
Wilson, Andy ;
Grenache, David G. .
CLINICA CHIMICA ACTA, 2010, 411 (1-2) :81-85