Numerical investigation of the effect of electrode arrangement and geometry on electrothermal fluid flow pumping and mixing in microchannel

被引:9
作者
Khakpour, Arezou [1 ]
Ramiar, Abas [1 ]
机构
[1] Babol Noshirvani Univ Technol, Fac Mech Engn, Microfluid & MEMs Lab, Babol Sar, Iran
关键词
OpenFOAM; Micromixer; Micropump; Electrode heating; Mixing quality; CHIP;
D O I
10.1016/j.cep.2020.107864
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Micro-mixers, due to their vast applications in different fields have been of great interest to the researchers in recent years. In this study, a transient two-dimensional solver was developed in the open-source code, OpenFOAM to simulate electrothermal effect in a micro mixer. Then, as the first step, the obtained mixing quality and fluid velocity of three different geometries with various electrode arrangements were compared. According to the results, the micromixer with a trapezoidal chamber and a circular cavity has the highest mixing and pumping efficiency. Then, in the selected micromixer, the effect of different parameters was studied such as voltage, electrode heating, electrical conductivity and size of electrode installed on the cavity and channel. The results showed that, in some phase differences, increasing the voltage improves the quality of mixing, and in others, it has an inverse effect. In addition, it is found that increasing size of electrodes in the cavity, decreases the fluid velocity and increases the mixing quality. Finally, by increasing voltage on different electrodes, a remarkable micro-mixer with a mixing quality of 99 % and an average fluid velocity of 64 mu m/s was obtained.
引用
收藏
页数:17
相关论文
共 32 条
[1]   High efficiency micromixing technique using periodic induced charge electroosmotic flow: A numerical study [J].
Alipanah, M. ;
Ramiar, A. .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2017, 524 :53-65
[2]   A numerical study of an electrothermal vortex enhanced micromixer [J].
Cao, J. ;
Cheng, P. ;
Hong, F. J. .
MICROFLUIDICS AND NANOFLUIDICS, 2008, 5 (01) :13-21
[3]   Microfluidic pumping optimization in microgrooved channels with ac electrothermal actuations [J].
Du, E. ;
Manoochehri, Souran .
APPLIED PHYSICS LETTERS, 2010, 96 (03)
[4]   Enhanced ac electrothermal fluidic pumping in microgrooved channels [J].
Du, E. ;
Manoochehri, Souran .
JOURNAL OF APPLIED PHYSICS, 2008, 104 (06)
[5]   Biofluid pumping and mixing by an AC electrothermal micropump embedded with a spiral microelectrode pair in a cylindrical microchannel [J].
Gao, Xiaobo ;
Li, Yuxiao .
ELECTROPHORESIS, 2018, 39 (24) :3156-3170
[6]   AC electrothermal actuation mechanism for on-chip mixing of high ionic strength fluids [J].
Ghandchi, Majid ;
Vafaie, Reza Hadjiaghaie .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (05) :1495-1507
[7]  
Jones T.B., 2005, ELECTROMECHANICS PAR
[8]   Analysis of micromixing of non-Newtonian fluids driven by alternating current electrothermal flow [J].
Kunti, Golak ;
Bhattacharya, Anandaroop ;
Chakraborty, Suman .
JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2017, 247 :123-131
[9]   In-plane microvortices micromixer-based AC electrothermal for testing drug induced death of tumor cells [J].
Lang, Qi ;
Ren, Yukun ;
Hobson, Divia ;
Tao, Ye ;
Hou, Likai ;
Jia, Yankai ;
Hu, Qingming ;
Liu, Jiangwei ;
Zhao, Xin ;
Jiang, Hongyuan .
BIOMICROFLUIDICS, 2016, 10 (06)
[10]   AC Electrothermal Circulatory Pumping Chip for Cell Culture [J].
Lang, Qi ;
Wu, Yanshuang ;
Ren, Yukun ;
Tao, Ye ;
Lei, Lei ;
Jiang, Hongyuan .
ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (48) :26792-26801