Fast generation of 4D PET-MR data from real dynamic MR acquisitions

被引:78
作者
Tsoumpas, C. [1 ]
Buerger, C. [1 ]
King, A. P. [1 ]
Mollet, P. [2 ]
Keereman, V. [2 ]
Vandenberghe, S. [2 ]
Schulz, V. [3 ]
Schleyer, P. [1 ]
Schaeffter, T. [1 ]
Marsden, P. K. [1 ]
机构
[1] Kings Coll London, Sch Med, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Univ Ghent, IBBT, B-9000 Ghent, Belgium
[3] Philips Res, Aachen, Germany
关键词
RESPIRATORY MOTION ESTIMATION; IMAGE-RECONSTRUCTION; HUMAN ANATOMY; SIMULATION; VALIDATION; ALGORITHM; SCANNER; SIMSET; PATH;
D O I
10.1088/0031-9155/56/20/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have implemented and evaluated a framework for simulating simultaneous dynamic PET-MR data using the anatomic and dynamic information from real MR acquisitions. PET radiotracer distribution is simulated by assigning typical FDG uptake values to segmented MR images with manually inserted additional virtual lesions. PET projection data and images are simulated using analytic forward projections (including attenuation and Poisson statistics) implemented within the image reconstruction package STIR. PET image reconstructions are also performed with STIR. The simulation is validated with numerical simulation based on Monte Carlo (GATE) which uses more accurate physical modelling, but has 150x slower computation time compared to the analytic method for ten respiratory positions and is 7000x slower when performing multiple realizations. Results are validated in terms of region of interest mean values and coefficients of variation for 65 million coincidences including scattered events. Although some discrepancy is observed, agreement between the two different simulation methods is good given the statistical noise in the data. In particular, the percentage difference of the mean values is 3.1% for tissue, 17% for the lungs and 18% for a small lesion. The utility of the procedure is demonstrated by simulating realistic PET-MR datasets from multiple volunteers with different breathing patterns. The usefulness of the toolkit will be shown for performance investigations of the reconstruction, motion correction and attenuation correction algorithms for dynamic PET-MR data.
引用
收藏
页码:6597 / 6613
页数:17
相关论文
共 32 条
[11]   Thoracic respiratory motion estimation from MRI using a statistical model and a 2-D image navigator [J].
King, A. P. ;
Buerger, C. ;
Tsoumpas, C. ;
Marsden, P. K. ;
Schaeffter, T. .
MEDICAL IMAGE ANALYSIS, 2012, 16 (01) :252-264
[12]   List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations [J].
Lamare, F. ;
Carbayo, M. J. Ledesma ;
Cresson, T. ;
Kontaxakis, G. ;
Santos, A. ;
Le Rest, C. Cheze ;
Reader, A. J. ;
Visvikis, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (17) :5187-5204
[13]   Incorporating Patient-Specific Variability in the Simulation of Realistic Whole-Body 18F-FDG Distributions for Oncology Applications [J].
Le Maitre, Amandine ;
Segars, William Paul ;
Marache, Simon ;
Reilhac, Anthonin ;
Hatt, Mathieu ;
Tomei, Sandrine ;
Lartizien, Carole ;
Visvikis, Dimitris .
PROCEEDINGS OF THE IEEE, 2009, 97 (12) :2026-2038
[14]  
Lewellen TK, 1998, MED SCI SER, P77
[15]   AMIDE: A Free Software Tool for Multimodality Medical Image Analysis [J].
Loening, Andreas Markus ;
Gambhir, Sanjiv Sam .
Molecular Imaging, 2003, 2 (03) :131-137
[16]   3D SIMULATION OF PET BRAIN IMAGES USING SEGMENTED MRI DATA AND POSITRON TOMOGRAPH CHARACTERISTICS [J].
MA, Y ;
KAMBER, M ;
EVANS, AC .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1993, 17 (4-5) :365-371
[17]   Analytical modeling of PET imaging with correlated functional and structural images [J].
Ma, YL ;
Evans, AC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) :2439-2444
[18]   Respiratory motion in positron emission tomography/computed tomography: A review [J].
Nehmeh, Sadek A. ;
Erdi, Yusuf E. .
SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (03) :167-176
[19]   Optimizing boundary detection via Simulated Search with applications to multi-modal heart segmentation [J].
Peters, J. ;
Ecabert, O. ;
Meyer, C. ;
Kneser, R. ;
Weese, J. .
MEDICAL IMAGE ANALYSIS, 2010, 14 (01) :70-84
[20]   PET-SORTEO: Validation and development of database of simulated PET volumes [J].
Reilhac, A ;
Batan, G ;
Michel, C ;
Grova, C ;
Tohka, J ;
Collins, DL ;
Costes, N ;
Evans, AC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) :1321-1328