Validation of artificial skin equivalents as in vitro testing systems

被引:1
|
作者
Schmitt, Robert [1 ,2 ]
Marx, Ulrich [2 ]
Walles, Heike [3 ]
Schober, Lena [3 ]
机构
[1] Rhein Westfal TH Aachen, Lab Machine Tools & Prod Engn WZL, Steinbachstr 19, D-52074 Aachen, Germany
[2] Fraunhofer Inst Prod Technol IPT, D-52074 Aachen, Germany
[3] Fraunhofer Inst Interfacial Engn & Biotechnol IGB, D-70569 Stuttgart, Germany
关键词
Optical Coherence Tomography; OCT; Artificial Skin Equivalent; ASE; In Vitro Monitoring; Tissue Engineering; Tissue Optics; Image Processing; OPTICAL COHERENCE TOMOGRAPHY;
D O I
10.1117/12.873804
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
With the increasing complexity of the chemical composition of pharmaceuticals, cosmetics and everyday substances, the awareness of potential health issues and long term damages for humanoid organs is shifting into focus. Artificial in vitro testing systems play an important role in providing reliable test conditions and replacing precarious animal testing. Especially artificial skin equivalents ASEs are used for a broad spectrum of studies like penetration, irritation and corrosion of substances. One major challenge in tissue engineering is the qualification of each individual ASE as in vitro testing system. Due to biological fluctuations, the stratum corneum hornified layer of some ASEs may not fully develop or other defects might occur. For monitoring these effects we developed an fully automated Optical Coherence Tomography device. Here, we present different methods to characterize and evaluate the quality of the ASEs based on image and data processing of OCT B-scans. By analysing the surface structure, defects, like cuts or tears, are detectable. A further indicator for the quality of the ASE is the morphology of the tissue. This allows to determine if the skin model has reached the final growth state. We found, that OCT is a well suited technology for automatically characterizing artificial skin equivalents and validating the application as testing system.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Testing & validation of disposable systems
    Uettwiller, I
    GENETIC ENGINEERING NEWS, 2006, 26 (03): : 54 - +
  • [32] Using in vitro human skin equivalents to understand the complexities of skin ageing and identify therapeutic interventions to restore skin health
    Smith, L.
    Costello, L.
    Low, E.
    Miwa, S.
    Alimohammadiha, G.
    Von Zglinicki, T.
    Bascom, C.
    Przyborski, S.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2022, 142 (08) : S21 - S21
  • [33] Development and validation of tissue-engineered human skin equivalents to detect stinging potential
    Harding, A.
    Danby, S.
    Murdoch, C.
    Hasan, M. Z.
    Colley, H.
    BRITISH JOURNAL OF DERMATOLOGY, 2022, 187 (01) : E31 - E31
  • [34] In vitro testing of an artificial muscle for the treatment of incontinence
    Lyko, Beate
    Gravert, Stephan-Daniel
    Katzschmann, Robert K.
    Mueller, Bert
    ELECTROACTIVE POLYMER ACTUATORS AND DEVICES, EAPAD XXVI, 2024, 12945
  • [35] KERATINOCYTE GRAFTS AND SKIN EQUIVALENTS
    CARVER, N
    LEIGH, IM
    INTERNATIONAL JOURNAL OF DERMATOLOGY, 1991, 30 (08) : 540 - 551
  • [36] A novel in vitro model for xenorejection and immune mechanisms using bioengineered living skin equivalents
    Ramsamooj, R
    Strande, L
    Kain, MH
    Doolin, EJ
    Hewitt, CW
    TRANSPLANTATION PROCEEDINGS, 1998, 30 (04) : 1087 - 1088
  • [37] In vitro skin corrosion: Human skin model test - A validation study
    Deshmukh, Gajanan Rajpal
    Kumar, Kuntrapakam Hema
    Reddy, Poojari Venkata Suresh
    Rao, Boddapati Srinivasa
    TOXICOLOGY IN VITRO, 2012, 26 (06) : 1072 - 1074
  • [38] Development of an in vitro method for skin corrosion testing
    Perkins, MA
    Osborne, R
    Johnson, GR
    FUNDAMENTAL AND APPLIED TOXICOLOGY, 1996, 31 (01): : 9 - 18
  • [39] HUMAN EPIDERMAL SKIN EQUIVALENTS
    Boyadjiev, Alexander
    Goncalves, Kirsty
    Maltman, Victoria
    Przyborski, Stefan
    Hoyle, Henry
    Smith, Lucy
    TISSUE ENGINEERING PART A, 2023, 29 (11-12) : 410 - 411
  • [40] Skin equivalents: clinical applications
    Braye, F
    Hautier, A
    Bouez, C
    Damour, O
    PATHOLOGIE BIOLOGIE, 2005, 53 (10): : 613 - 617