Influence of rotator cuff integrity on loading and kinematics before and after reverse shoulder arthroplasty

被引:4
作者
Pean, Fabien [1 ]
Favre, Philippe [2 ]
Goksel, Orcun [1 ]
机构
[1] Swiss Fed Inst Technol, Comp Assisted Applicat Med CAiM, CH-8092 Zurich, Switzerland
[2] Zimmer Biomet, Winterthur, Switzerland
关键词
Musculoskeletal simulation; Shoulder; Upper extremity; Rotator cuff tear; Reverse arthroplasty; Joint reaction force; GLENOHUMERAL JOINT; MUSCLE FORCES; UPPER EXTREMITY; MODEL; DESIGN; REVISION; COMPLICATIONS; SUPRASPINATUS; REPLACEMENT; STABILITY;
D O I
10.1016/j.jbiomech.2021.110778
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Reverse Shoulder Arthroplasty has become a very common procedure for shoulder joint replacement, even for scenarios where an anatomical reconstruction would traditionally be used. Our hypothesis is that implanting a reverse prosthesis with a functional rotator cuff may lead to higher joint reaction force (JRF) and have a negative impact on the prosthesis. Available motion capture data during anterior flexion was input to a finite-element musculoskeletal shoulder model, and muscle activations were computed using inverse dynamics. Simulations were carried out for the intact joint as well as for various types of rotator cuff tears: superior (supraspinatus), superior-anterior (supraspinatus and subscapularis), and superior-posterior (supraspinatus, infraspinatus and teres minor). Each rotator cuff tear condition was repeated after shifting the humerus and the glenohumeral joint center of rotation to represent the effect of a reverse prosthesis. Changes in compressive, shear, and total JRF were analyzed. The model compared favorably to in vivo JRF measurements, and existing clinical and biomechanical knowledge. Implanting a reverse prosthesis with a functional rotator cuff or with an isolated supraspinatus tear led to more than 2 times higher compressive JRF than with massive rotator cuff tears (superior anterior or superior-posterior), while the shear force remained comparable. The total JRF increased more than 1.5 times. While a lower shear to compressive ratio may reduce the risk of glenosphere loosening, higher JRF might increase the risk for other failure modes such as fracture or polyethylene wear of the reverse prosthesis.
引用
收藏
页数:7
相关论文
共 59 条
  • [51] Automatic prediction of tongue muscle activations using a finite element model
    Stavness, Ian
    Lloyd, John E.
    Fels, Sidney
    [J]. JOURNAL OF BIOMECHANICS, 2012, 45 (16) : 2841 - 2848
  • [52] Glenohumeral stability in simulated rotator cuff tears
    Steenbrink, F.
    de Groot, J. H.
    Veeger, H. E. J.
    van der Helm, F. C. T.
    Rozing, P. M.
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (11) : 1740 - 1745
  • [53] Simulated joint and muscle forces in reversed and anatomic shoulder prostheses
    Terrier, A.
    Reist, A.
    Merlini, F.
    Farron, A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (06): : 751 - 756
  • [54] Modeling a rotator cuff tear: Individualized shoulder muscle forces influence glenohumeral joint contact force predictions
    Vidt, Meghan E.
    Santago, Anthony C., II
    Marsh, Anthony P.
    Hegedus, Eric J.
    Tuohy, Christopher J.
    Poehling, Gary G.
    Freehill, Michael T.
    Miller, Michael E.
    Saul, Katherine R.
    [J]. CLINICAL BIOMECHANICS, 2018, 60 : 20 - 29
  • [55] Scapulohumeral rhythm in shoulders with reverse shoulder arthroplasty
    Walker, David
    Matsuki, Keisuke
    Struk, Aimee M.
    Wright, Thomas W.
    Banks, Scott A.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (07) : 1129 - 1134
  • [56] The use of the reverse shoulder arthroplasty for treatment of failed total shoulder arthroplasty
    Walker, Matthew
    Willis, Matthew P.
    Brooks, Jordan P.
    Pupello, Derek
    Mulieri, Philip J.
    Frankle, Mark A.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (04) : 514 - 522
  • [57] 3D finite element models of shoulder muscles for computing lines of actions and moment arms
    Webb, Joshua D.
    Blemker, Silvia S.
    Delp, Scott L.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (08) : 829 - 837
  • [58] An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint
    Westerhoff, P.
    Graichen, F.
    Bender, A.
    Rohmann, A.
    Bergmann, G.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2009, 31 (02) : 207 - 213
  • [59] ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion - Part II: shoulder, elbow, wrist and hand
    Wu, G
    van der Helm, FCT
    Veeger, HEJ
    Makhsous, M
    Van Roy, P
    Anglin, C
    Nagels, J
    Karduna, AR
    McQuade, K
    Wang, XG
    Werner, FW
    Buchholz, B
    [J]. JOURNAL OF BIOMECHANICS, 2005, 38 (05) : 981 - 992