Influence of rotator cuff integrity on loading and kinematics before and after reverse shoulder arthroplasty

被引:4
作者
Pean, Fabien [1 ]
Favre, Philippe [2 ]
Goksel, Orcun [1 ]
机构
[1] Swiss Fed Inst Technol, Comp Assisted Applicat Med CAiM, CH-8092 Zurich, Switzerland
[2] Zimmer Biomet, Winterthur, Switzerland
关键词
Musculoskeletal simulation; Shoulder; Upper extremity; Rotator cuff tear; Reverse arthroplasty; Joint reaction force; GLENOHUMERAL JOINT; MUSCLE FORCES; UPPER EXTREMITY; MODEL; DESIGN; REVISION; COMPLICATIONS; SUPRASPINATUS; REPLACEMENT; STABILITY;
D O I
10.1016/j.jbiomech.2021.110778
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Reverse Shoulder Arthroplasty has become a very common procedure for shoulder joint replacement, even for scenarios where an anatomical reconstruction would traditionally be used. Our hypothesis is that implanting a reverse prosthesis with a functional rotator cuff may lead to higher joint reaction force (JRF) and have a negative impact on the prosthesis. Available motion capture data during anterior flexion was input to a finite-element musculoskeletal shoulder model, and muscle activations were computed using inverse dynamics. Simulations were carried out for the intact joint as well as for various types of rotator cuff tears: superior (supraspinatus), superior-anterior (supraspinatus and subscapularis), and superior-posterior (supraspinatus, infraspinatus and teres minor). Each rotator cuff tear condition was repeated after shifting the humerus and the glenohumeral joint center of rotation to represent the effect of a reverse prosthesis. Changes in compressive, shear, and total JRF were analyzed. The model compared favorably to in vivo JRF measurements, and existing clinical and biomechanical knowledge. Implanting a reverse prosthesis with a functional rotator cuff or with an isolated supraspinatus tear led to more than 2 times higher compressive JRF than with massive rotator cuff tears (superior anterior or superior-posterior), while the shear force remained comparable. The total JRF increased more than 1.5 times. While a lower shear to compressive ratio may reduce the risk of glenosphere loosening, higher JRF might increase the risk for other failure modes such as fracture or polyethylene wear of the reverse prosthesis.
引用
收藏
页数:7
相关论文
共 59 条
  • [1] Revision of an unstable hemiarthroplasty or anatomical total shoulder replacement using a reverse design prosthesis
    Abdel, M. P.
    Hattrup, S. J.
    Sperling, J. W.
    Cofield, R. H.
    Kreofsky, C. R.
    Sanchez-Sotelo, J.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (05) : 668 - 672
  • [2] Muscle and Joint-Contact Loading at the Glenohumeral Joint after Reverse Total Shoulder Arthroplasty
    Ackland, David C.
    Roshan-Zamir, Sasha
    Richardson, Martin
    Pandy, Marcus G.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (12) : 1850 - 1858
  • [3] Three-dimensional motion of the upper extremity joints during various activities of daily living
    Aizawa, Junya
    Masuda, Tadashi
    Koyama, Takayuki
    Nakamaru, Koji
    Isozaki, Koji
    Okawa, Atsushi
    Morita, Sadao
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (15) : 2915 - 2922
  • [4] Reverse shoulder arthroplasty. Part 2: Systematic review of reoperations, revisions, problems, and complications
    Alentorn-Geli, Eduard
    Samitier, Gonzalo
    Torrens, Carlos
    Wright, Thomas W.
    [J]. INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2015, 9 (02): : 60 - 67
  • [5] Torus obstacle method as a wrapping approach of the deltoid muscle group for humeral abduction in musculoskeletal simulation
    Aurbach, M.
    Spicka, J.
    Suess, F.
    Vychytil, J.
    Havelkova, L.
    Ryba, T.
    Dendorfer, S.
    [J]. JOURNAL OF BIOMECHANICS, 2020, 109 (109)
  • [6] Complications in reverse shoulder arthroplasty
    Barco, Raul
    Savvidou, Olga D.
    Sperling, John W.
    Sanchez-Sotelo, Joaquin
    Cofield, Robert H.
    [J]. EFORT OPEN REVIEWS, 2016, 1 (03): : 72 - 80
  • [7] In vivo gleno-humeral joint loads during forward flexion and abduction
    Bergmann, G.
    Graichen, F.
    Bender, A.
    Rohlmann, A.
    Halder, A.
    Beier, A.
    Westerhoff, P.
    [J]. JOURNAL OF BIOMECHANICS, 2011, 44 (08) : 1543 - 1552
  • [8] Bergmann G., 2008, ORTHOLOAD
  • [9] A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii
    Blemker, SS
    Pinsky, PM
    Delp, SL
    [J]. JOURNAL OF BIOMECHANICS, 2005, 38 (04) : 657 - 665
  • [10] Grammont reverse prosthesis: Design, rationale, and biomechanics
    Boileau, P
    Watkinson, DJ
    Hatzidakis, AM
    Balg, F
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) : 147S - 161S