Biomechanical effects of kneeling after total knee arthroplasty

被引:27
作者
Wilkens, Kenneth J.
Duong, Long V.
McGarry, Michelle H.
Kim, William C.
Lee, Thay Q.
机构
[1] VA Long Beach Healthcare Syst, Orthopaed Biomech Lab, Long Beach, CA 90822 USA
[2] Univ Calif Irvine, Dept Orthopaed Surg, Irvine, CA USA
关键词
D O I
10.2106/JBJS.E.01201
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Kneeling following total knee arthroplasty can be a difficult task, impairing the activities of patients to varying degrees. Little is known about the biomechanical effects of kneeling following total knee replacement. The objective of this study was to quantify the effects of kneeling on patellofemoral joint contact areas and pressures, knee joint reaction force, and patellar kinematics. Methods: Total knee arthroplasties were performed on eight fresh-frozen cadaveric knees, and they were tested with use of a custom knee jig, which permits the simulation of physiologic quadriceps loading as well as the application of an anterior force to simulate kneeling. The knees were tested at flexion angles of 90 degrees,.105 degrees, 120 degrees, and 135 degrees with no anterior force (mimicking a squatting position) and with an anterior force application simulating double-stance kneeling and single-stance kneeling. Patellofemoral joint contact areas and pressures were measured with pressure-sensitive film, and the knee joint reaction force was measured with use of a six-degree-of-freedom load cell. Patellar kinematics were assessed with use of digital photographs tracking fixed markers on the patella. Results: Compared with the condition without kneeling, both single-stance and double-stance kneeling demonstrated significant increases in patellofemoral contact area (p < 0.05) and pressure at all flexion angles (p < 0.05), with the exception of double-stance kneeling at 1350 of flexion. The resultant knee joint -reaction force increased with kneeling at all flexion angles. The compressive component of this force increased with kneeling for most conditions, while the lateral component of this force decreased significantly (p < 0.05) with kneeling only at 900, and the anterior component of this force increased significantly at all knee flexion angles (p < 0.05). Overall, kneeling had minimal changes on patellar tilt, with significant changes in patellar tilt seen only with kneeling at 1200 (p = 0.02 for double stance, and p = 0.03 for single stance). Conclusions: The findings of this study suggest that kneeling at a higher flexion angle (135 degrees) after total knee arthroplasty has a smaller effect on patellofemoral joint contact area and pressure than kneeling at lower flexion angles (<= 120 degrees).
引用
收藏
页码:2745 / 2751
页数:7
相关论文
共 17 条
[1]   A STEREOPHOTOGRAMMETRIC METHOD FOR DETERMINING IN-SITU CONTACT AREAS IN DIARTHROIDAL JOINTS, AND A COMPARISON WITH OTHER METHODS [J].
ATESHIAN, GA ;
KWAK, SD ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :111-124
[2]  
BARTEL DL, 1995, CLIN ORTHOP RELAT R, P76
[3]  
BINGENHEIMER E, 2005, T ORTHOP RES SOC, V30, P484
[4]  
CAMERON HU, 1993, CAN J SURG, V36, P560
[5]  
ELBERT K, 1995, CLIN ORTHOP RELAT R, P71
[6]   CONTACT STRESS GRADIENT DETECTION LIMITS OF PRESSENSOR FILM [J].
HALE, JE ;
BROWN, TD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (03) :352-357
[7]   Kneeling requirements and arthroplasty surgery [J].
Hassaballa, M ;
Vale, T ;
Weeg, N ;
Hardy, JRW .
KNEE, 2002, 9 (04) :317-319
[8]   Patellofemoral joint kinematics and contact pressures in total knee arthroplasty [J].
Lee, TQ ;
Gerken, AP ;
Glaser, FE ;
Kim, WC ;
Anzel, SH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (340) :257-266
[9]  
Lee TQ, 1999, CLIN ORTHOP RELAT R, P274
[10]   Ability to kneel after total knee replacement [J].
Palmer, SH ;
Servant, CT ;
Maguire, J ;
Parish, EN ;
Cross, MJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (02) :220-222