Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields

被引:18
|
作者
Padilla-Cabal, Fatima [1 ,2 ]
Alejandro Fragoso, Jose [3 ]
Resch, Andreas Franz [1 ,2 ]
Georg, Dietmar [1 ,2 ]
Fuchs, Hermann [1 ,2 ]
机构
[1] Med Univ Vienna AKH, Dept Radiotherapy, Vienna, Austria
[2] Med Univ Vienna, Christian Doppler Lab Med Radiat Res Radiat Oncol, Vienna, Austria
[3] Higher Inst Technol & Appl Sci, Dept Nucl Phys, Havana, Cuba
基金
奥地利科学基金会;
关键词
beam modeling; magnetic fields; MC simulations; proton therapy; RADIOCHROMIC FILM DOSIMETRY; FLAT-BED SCANNERS; DOSE CALCULATION; EBT3; FILM; THERAPY; SIMULATION; CARBON; FEASIBILITY; VALIDATION; DEFLECTION;
D O I
10.1002/mp.13883
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeMagnetic resonance guidance in proton therapy (MRPT) is expected to improve its current performance. The combination of magnetic fields with clinical proton beam lines poses several challenges for dosimetry, treatment planning and dose delivery. Proton beams are deflected by magnetic fields causing considerable changes in beam trajectories and also a retraction of the Bragg peak positions. A proper prediction and compensation of these effects is essential to ensure accurate dose calculations. This work aims to develop and benchmark a Monte Carlo (MC) beam model for dose calculation of MRPT for static magnetic fields up to 1 T. MethodsProton beam interactions with magnetic fields were simulated using the GATE/Geant4 toolkit. The transport of charged particle in custom 3D magnetic field maps was implemented for the first time in GATE. Validation experiments were done using a horizontal proton pencil beam scanning system with energies between 62.4 and 252.7 MeV and a large gap dipole magnet (B = 0-1 T), positioned at the isocenter and creating magnetic fields transverse to the beam direction. Dose was measured with Gafchromic EBT3 films within a homogeneous PMMA phantom without and with bone and tissue equivalent material slab inserts. Linear energy transfer (LET) quenching of EBT3 films was corrected using a linear model on dose-averaged LET method to ensure a realistic dosimetric comparison between simulations and experiments. Planar dose distributions were measured with the films in two different configurations: parallel and transverse to the beam direction using single energy fields and spread-out Bragg peaks. The MC model was benchmarked against lateral deflections and spot sizes in air of single beams measured with a Lynx PT detector, as well as dose distributions using EBT3 films. Experimental and calculated dose distributions were compared to test the accuracy of the model. ResultsMeasured proton beam deflections in air at distances of 465, 665, and 1155 mm behind the isocenter after passing the magnetic field region agreed with MC-predicted values within 4 mm. Differences between calculated and measured beam full width at half maximum (FWHM) were lower than 2 mm. For the homogeneous phantom, measured and simulated in-depth dose profiles showed range and average dose differences below 0.2 mm and 1.2%, respectively. Simulated central beam positions and widths differed <1 mm to the measurements with films. For both heterogenous phantoms, differences within 1 mm between measured and simulated central beam positions and widths were obtained, confirming a good agreement of the MC model. ConclusionsA GATE/Geant4 beam model for protons interacting with magnetic fields up to 1 T was developed and benchmarked to experimental data. For the first time, the GATE/Geant4 model was successfully validated not only for single energy beams, but for SOBP, in homogeneous and heterogeneous phantoms. EBT3 film dosimetry demonstrated to be a powerful dosimetric tool, once the film response function is LET corrected, for measurements in-line and transverse to the beam direction in magnetic fields. The proposed MC beam model is foreseen to support treatment planning and quality assurance (QA) activities toward MRPT.
引用
收藏
页码:223 / 233
页数:11
相关论文
共 50 条
  • [21] Geant4 Monte Carlo simulations for the LPCTrap setup
    Rodriguez, D.
    Ban, G.
    Durand, D.
    Duval, F.
    Flechard, X.
    Lienard, E.
    Mauger, F.
    Mery, A.
    Naviliat-Cuncic, O.
    Thomas, J. -C.
    Velten, Ph.
    EUROPEAN PHYSICAL JOURNAL A, 2009, 42 (03): : 397 - 400
  • [22] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Kim, Dae-Hyun
    Kang, Young Nam
    Suh, Tae-Suk
    Shin, Jungwook
    Kim, Jong Won
    Yoo, Seung Hoon
    Park, Seyjoon
    Lee, Sang Hoon
    Cho, Sungkoo
    Shin, Dongho
    Kim, Dae Yong
    Lee, Se Byeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (07) : 1125 - 1130
  • [23] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Dae-Hyun Kim
    Young Nam Kang
    Tae-Suk Suh
    Jungwook Shin
    Jong Won Kim
    Seung Hoon Yoo
    Seyjoon Park
    Sang Hoon Lee
    Sungkoo Cho
    Dongho Shin
    Dae Yong Kim
    Se Byeong Lee
    Journal of the Korean Physical Society, 2012, 61 : 1125 - 1130
  • [24] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [25] Fano Cavity Test of the Monte Carlo Codes GEANT4 and PENH for Proton Transport
    Sterpin, E.
    Sorriaux, J.
    Vynckier, S.
    Bouchard, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    The European Physical Journal A, 2009, 42 : 397 - 400
  • [27] Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields
    Gholami, Somayeh
    Longo, Francesco
    Nedaie, Hassan Ali
    Berti, Alessio
    Mousavi, Mehdi
    Meigooni, Ali S.
    MEDICAL DOSIMETRY, 2018, 43 (03) : 214 - 223
  • [28] Polarized electron Mott scattering model for the Geant4 Monte Carlo toolkit
    Dragowski, M.
    Adamus, M.
    Weber, G.
    Wlodarczyk, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2021, 488 : 37 - 42
  • [29] RADIOTHERAPY MONTE CARLO DOSIMETRY USING GATE/GEANT4: VALIDATION STUDY IN ANTHROPOMORPHIC PHANTOM
    Perrot, Y.
    Breton, V.
    Donnarieix, D.
    Maigne, L.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S491 - S492
  • [30] Monte Carlo (GATE/Geant4) Estimation of Clinician Hand Dose from Radionuclide Injection
    Edelman, H.
    Loughery, B.
    MEDICAL PHYSICS, 2021, 48 (06)