Quantification of Glucose Diffusion in Human Lung Tissues by Using Fourier Domain Optical Coherence Tomography

被引:9
作者
Guo, Xiao [1 ,2 ]
Wu, Guoyong [3 ]
Wei, Huajiang [1 ,2 ]
Deng, Xiaoyuan [1 ,2 ]
Yang, Hongqin [4 ]
Ji, Yanhong [1 ,2 ]
He, Yonghong [5 ]
Guo, Zhouyi [1 ,2 ]
Xie, Shusen [4 ]
Zhong, Huiqing [1 ,2 ]
Zhao, Qingliang [1 ,2 ]
Zhu, Zhenguo [1 ,2 ]
机构
[1] S China Normal Univ, MOE Key Lab Laser Life Sci, Guangzhou, Guangdong, Peoples R China
[2] S China Normal Univ, Coll Biophoton, Inst Laser Life Sci, Guangzhou, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Dept Surg, Affiliated Hosp 1, Guangzhou 510275, Guangdong, Peoples R China
[4] Fujian Normal Univ, Key Lab Optoelect Sci & Technol Med, Minist Educ China, Fuzhou, Fujian, Peoples R China
[5] Tsinghua Univ, Grad Sch Shenzhen, Shenzhen 518057, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
AIRWAYS MICROSTRUCTURE; IN-VITRO; CANCER; SKIN; DIAGNOSIS; AGENTS; FEASIBILITY; IMMERSION; SURGERY;
D O I
10.1111/j.1751-1097.2011.01065.x
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this study, we report permeability coefficients of 30% glucose diffusion by the optical coherence tomography signal slope (OCTSS) method in four kinds of human lung tissue in vitro: normal lung tissue, benign granulomatosis lung tissue, squamous cell carcinoma and adenocarcinoma tumor. To quantify the permeability coefficient of the agent, the monitored region was 80 mu m thickness at a tissue depth of ca 230 mu m from the surface. The permeability coefficients of 30% glucose from 10 independent experiments were averaged and found to be (1.35 +/- 0.13) x 10-5 cm s-1 from the normal lung tissue, (1.78 +/- 0.21) x 10-5 cm s-1 from the benign granulomatosis lung tissue, (2.88 +/- 0.19) x 10-5 cm s-1 from the adenocarcinoma tumor and (3.53 +/- 0.25) x 10-5 cm s-1 from the squamous cell carcinoma, respectively. It could be clearly seen that the permeability coefficients of 30% glucose increase ca 32%, 113% and 162% in the benign granulomatosis, adenocarcinoma tumor and squamous cell carcinoma of human lung tissue compared with that from the normal lung tissue, respectively. Therefore, we inferred from this pilot study that the OCT imaging is a feasible method to distinguish normal and cancer lung tissue.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 52 条
[1]   Glucose and mannitol diffusion in human dura mater [J].
Bashkatov, AN ;
Genina, EA ;
Sinichkin, YP ;
Kochubey, VI ;
Lakodina, NA ;
Tuchin, VV .
BIOPHYSICAL JOURNAL, 2003, 85 (05) :3310-3318
[2]   Optical coherence tomography: feasibility for basic research and image-guided surgery of breast cancer [J].
Boppart, SA ;
Luo, W ;
Marks, DL ;
Singletary, KW .
BREAST CANCER RESEARCH AND TREATMENT, 2004, 84 (02) :85-97
[3]   Determination of chemical agent optical clearing potential using in vitro human skin [J].
Choi, B ;
Tsu, L ;
Chen, E ;
Ishak, TS ;
Iskandar, SM ;
Chess, S ;
Nelson, JS .
LASERS IN SURGERY AND MEDICINE, 2005, 36 (02) :72-75
[4]   Modulating the skin barrier function by DMSO: molecular dynamics simulations of hydrophilic and hydrophobic transmembrane pores [J].
den Otter, W. K. ;
Notman, R. ;
Anwar, J. ;
Noro, M. G. ;
Briels, W. J. .
CHEMISTRY AND PHYSICS OF LIPIDS, 2008, 154 :S2-S3
[5]   Optical coherence tomography evaluation of ulcerative colitis: The patterns and the comparison with histology [J].
Familiari, Luigi ;
Strangio, Giuseppe ;
Consolo, Pierluigi ;
Luigiano, Carmelo ;
Bonica, Marisa ;
Barresi, Gaetano ;
Barresi, Valeria ;
Familiari, Pietro ;
D'Arrigo, Graziella ;
Alibrandi, Angela ;
Zirilli, Agata ;
Fries, Walter ;
Scaffidi, Mariagrazia .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (12) :2833-2840
[6]  
Gansler T, 2010, CA-CANCER J CLIN, V60, P1, DOI [10.3322/caac.20073, 10.3322/caac.20049]
[7]   Quantification of molecular diffusion in arterial tissues with optical coherence tomography and fluorescence microscopy [J].
Ghosn, M. G. ;
Syed, S. H. ;
Befrui, N. A. ;
Leba, M. ;
Vijayananda, A. ;
Sudheendran, N. ;
Larin, K. V. .
LASER PHYSICS, 2009, 19 (06) :1272-1275
[8]   Nondestructive quantification of analyte diffusion in cornea and sclera using optical coherence tomography [J].
Ghosn, Mohamad G. ;
Tuchin, Valery V. ;
Larin, Kirill V. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (06) :2726-2733
[9]   Depth-resolved monitoring of glucose diffusion in tissues by using optical coherence tomography [J].
Ghosn, Mohamad G. ;
Tuchin, Valery V. ;
Larin, Kirill V. .
OPTICS LETTERS, 2006, 31 (15) :2314-2316
[10]   Monitoring of glucose permeability in monkey skin in vivo using Optical Coherence Tomography [J].
Ghosn, Mohamad G. ;
Sudheendran, Narendran ;
Wendt, Mark ;
Glasser, Adrian ;
Tuchin, Valery V. ;
Larin, Kirill V. .
JOURNAL OF BIOPHOTONICS, 2010, 3 (1-2) :25-33