Experimental study on flow boiling characteristics of pure refrigerant (R134a) and zeotropic mixture (R407C) in a rectangular micro-channel

被引:41
作者
Dang, Chao
Jia, Li [1 ]
Xu, Mingchen
Huang, Qian
Peng, Qi
机构
[1] Beijing Jiaotong Univ, Sch Mech Elect & Control Engn, Inst Thermal Engn, Beijing 100044, Peoples R China
关键词
Flow boiling; Visualization; Zeotropic mixture; Ma number; New correlation; HEAT-TRANSFER CHARACTERISTICS; HORIZONTAL SMOOTH TUBE; TRANSFER COEFFICIENTS; MIXED REFRIGERANTS; DIAMETER CHANNELS; BINARY-MIXTURES; PRESSURE-DROP; PREDICTION; PATTERN; FLUX;
D O I
10.1016/j.ijheatmasstransfer.2016.08.067
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present study, the flow boiling characteristics of pure refrigerant R134a and zeotropic mixture R407C are experimentally investigated in a single visualized rectangular micro-channel heated on three sides with the cross-sectional area of 1 mm x 1 mm and length of 106 mm. Boiling heat transfer coefficients are obtained at the saturation temperature of 21 degrees C under the heat flux and mass flux ranging from 30-150 kW/m(2) and 35-1400 kg/m(2) s, respectively. The boiling curves of the two refrigerants are also discussed. Based on the visualization results, seven flow types are identified and the flow pattern maps are plotted. Through the comparative study, the phenomena of advance into churn-annular flow and coexistent bubbles with the flow patterns from confined bubble to annular are observed for R407C. The boiling heat transfer coefficient of R407C is slightly higher than that for R134a at lower vapor quality while the opposite situation appears with the increasing vapor quality after that. During churn-annular to annular flow stage, the boiling heat transfer coefficient of R407C presents a declining trend which is obviously different from the relatively stable value of R134a. The nucleate boiling heat transfer of R407C is suppressed during bubbly flow but promoted in confined bubble to slug flow stage compared with R134a. The CHF of R407C is higher than that of R134a. A correlation for the flow boiling heat transfer coefficient of mixtures is proposed in consideration of Ma number and predicts satisfactorily the database of R407C and R404A. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:351 / 361
页数:11
相关论文
共 40 条
[1]   Flow boiling characteristics of R134a and R245fa mixtures in a vertical circular tube [J].
Abadi, Gholamreza Bamorovat ;
Yun, Eunkoo ;
Kim, Kyung Chun .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 72 :112-124
[2]  
[Anonymous], 1973, AICHE SYM SER
[3]   Comparison of R407C and R417A heat transfer coefficients and pressure drops during flow boiling in a horizontal smooth tube [J].
Aprea, C. ;
Greco, A. ;
Rosato, A. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) :1629-1636
[4]   Bubble dynamics and flow boiling instabilities in microchannels [J].
Bogojevic, D. ;
Sefiane, K. ;
Duursma, G. ;
Walton, A. J. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 58 (1-2) :663-675
[5]  
Dittus F.W., 1985, Int. Commun. Heat Mass, V12, P3, DOI [10.1016/0735-1933(85)90003-X, DOI 10.1016/0735-1933(85)90003-X]
[6]   A new correlation of flow boiling heat transfer coefficients based on R134a data [J].
Fang, Xiande .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 66 :279-283
[7]   Flow pattern maps and transition criteria for flow boiling of binary mixtures in a diverging microchannel [J].
Fu, B. R. ;
Lin, P. H. ;
Tsou, M. S. ;
Pan, Chin .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (5-6) :1754-1763
[8]   Critical heat flux of binary mixtures in pool boiling and its correlation in terms of Marangoni number [J].
Fujita, Y ;
Bai, Q .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (08) :616-622
[9]  
Gnielinskl V., 1976, INT CHEM ENG, P403