Cervical muscle strength measurement is dependent on the location of thoracic support

被引:15
作者
Rezasoltani, A. [1 ,2 ]
Ylinen, J. [3 ]
Bakhtiary, A-H [4 ]
Norozi, M. [1 ]
Montazeri, M. [1 ]
机构
[1] Shahid Beheshti Univ Med Sci, Fac Rehabil, Dept Physiotherapy, Tehran 16169, Iran
[2] Shahid Beheshti Univ Med Sci, Talagani Gen Hosp, Tehran 16169, Iran
[3] Jyvaskyla Cent Hosp, Dept Phys & Rehabil Med, Jyvaskyla, Finland
[4] Semnan Univ Med Sci & Hlth Serv, Fac Rehabil, Dept Physiotherapy, Semnan, Iran
关键词
D O I
10.1136/bjsm.2007.040709
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: In all studies in which the strength of the neck extensor muscles has been measured, the level of thoracic support has been adjusted differently so direct comparison of the results is not possible. Objective: To measure and compare the isometric force and isometric torque of neck extensor muscles at different levels of thoracic support. Methods: Twenty healthy women volunteered for the study. The maximum isometric force of the neck extensor muscles was measured with the thoracic support located at five different levels. The highest level was set at the level of the spine of the scapula ( level I) and the other levels were located 2.5 cm lower than the previous one, with the lowest level set 10 cm below the highest level. The maximum isometric torque for each level was calculated by multiplying the isometric force by the length of the lever arm measured from the upper tip of the thoracic support to the centre point of the cell load at the occiput. Results: The maximum isometric force and maximum isometric torque of the neck extensor muscles were increased step by step from 130.5 N to 138.9 N, 141.9 N, 147.9 N and 155.4 N and from 33.7 Nm to 38.7 Nm, 42.5 Nm, 47.2 Nm and 52.7 Nm, respectively. Except for the isometric force of the cervical extensor muscles measured at levels II and III, the differences between the other levels were significant ( p < 0.05). There was a significant correlation between isometric force and isometric torque measurements of the neck extensor muscles at different levels (0.81 < r < 0.96). Conclusion: Maximum isometric force and maximum isometric torque measurements of the neck extensor muscles vary with the length of the lever arm. It is recommended that a specific level of thoracic support should be used in follow-up and intervention studies. Setting the level of thoracic support at a specific level will make it possible to compare the strength of the neck extensor muscles in different studies. Measurements at the level of the spine of the scapula were easier and less time consuming.
引用
收藏
页码:379 / 382
页数:4
相关论文
共 50 条
  • [1] The Human Muscle Size and Strength Relationship: Effects of Architecture, Muscle Force, and Measurement Location
    Balshaw, Thomas G.
    Maden-Wilkinson, Thomas M.
    Massey, Garry J.
    Folland, Jonathan P.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2021, 53 (10) : 2140 - 2151
  • [2] Effects of exercise on cervical muscle strength and cross-sectional area in patients with thoracic hyperkyphosis and chronic cervical pain
    Hyunghun Moon
    Sung-Ki Lee
    Won-Moon Kim
    Yong-Gon Seo
    Scientific Reports, 11
  • [3] Effects of exercise on cervical muscle strength and cross-sectional area in patients with thoracic hyperkyphosis and chronic cervical pain
    Moon, Hyunghun
    Lee, Sung-Ki
    Kim, Won-Moon
    Seo, Yong-Gon
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [4] Cervical and thoracic/lumbar motion and muscle strength in surgically treated adolescent idiopathic scoliosis patients
    Turan, Kayhan
    Kara, Gokhan Kursat
    Camurcu, Yalkin
    Kizilay, Yusuf Onur
    Uysal, Yunus
    Sahin, Ecem
    Aydinli, Ufuk
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2022, 35 (06) : 1337 - 1343
  • [5] MEASUREMENT OF MUSCLE STRENGTH
    MILCH, H
    JOURNAL OF BONE AND JOINT SURGERY, 1945, 27 (01): : 137 - 141
  • [6] MUSCLE STRENGTH MEASUREMENT
    SEEDHOM, B
    YANG, PT
    YEOH, SH
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1982, 5 (03) : 459 - 459
  • [7] CERVICAL AND THORACIC MUSCULATURE OF LEPIDOPTERA .3. COMPARISON OF MUSCLE CATEGORIES IN CERVICAL AND THORACIC REGIONS
    BHARADWAJ, RK
    CHANDRAN, RS
    CHADWICK, LE
    JOURNAL OF NATURAL HISTORY, 1974, 8 (03) : 333 - 343
  • [8] Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength
    Vannebo, Katrine Tranaas
    Iversen, Vegard Moe
    Fimland, Marius Steiro
    Mork, Paul Jarle
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2018, 31 (03) : 557 - 565
  • [9] Measurement of muscle strength and power
    Bassey, EJ
    MUSCLE & NERVE, 1997, : S44 - S46
  • [10] MEASUREMENT OF MUSCLE STRENGTH IN CHILDREN
    MACHEK, J
    VAVRA, J
    RADVANSKY, J
    MACEK, M
    PISTEK, M
    SLEMINKOVA, J
    KRUPOVA, M
    KRYL, L
    TAXOVA, P
    LEHOVSKY, M
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (04): : P43 - P43