Application of HPLC-QQQ-MS/MS and New RP-HPLC-DAD System Utilizing the Chaotropic Effect for Determination of Nicotine and Its Major Metabolites Cotinine, and trans-3′-Hydroxycotinine in Human Plasma Samples

被引:7
|
作者
Baj, Jacek [1 ]
Flieger, Wojciech [1 ]
Przygodzka, Dominika [2 ]
Buszewicz, Grzegorz [2 ]
Teresinski, Grzegorz [2 ]
Pizon, Magdalena [3 ]
Maciejewski, Ryszard [1 ]
Flieger, Jolanta [3 ]
机构
[1] Med Univ Lublin, Dept Anat, Jaczewskiego 4, PL-20090 Lublin, Poland
[2] Med Univ Lublin, Dept Forens Med, PL-20090 Lublin, Poland
[3] Med Univ Lublin, Dept Analyt Chem, Chodzki 4A, PL-20093 Lublin, Poland
来源
MOLECULES | 2022年 / 27卷 / 03期
关键词
nicotine; cotinine; trans-3 '-hydroxycotinine; RP-HPLC-DAD; HPLC-QQQ-MS/; MS chaotropic effect; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; MINOR TOBACCO ALKALOIDS; SOLID-PHASE EXTRACTION; HUMAN URINE; SIMULTANEOUS QUANTIFICATION; SERUM NICOTINE; SMOKE EXPOSURE; VALIDATION; SALIVA;
D O I
10.3390/molecules27030682
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The routine techniques currently applied for the determination of nicotine and its major metabolites, cotinine, and trans-3 & PRIME;-hydroxycotinine, in biological fluids, include spectrophotometric, immunoassays, and chromatographic techniques. The aim of this study was to develop, and compare two new chromatographic methods high-performance liquid chromatography coupled to triple quadrupole mass spectrometry (HPLC-QQQ-MS/MS), and RP-HPLC enriched with chaotropic additives, which would allow reliable confirmation of tobacco smoke exposure in toxicological and epidemiological studies. The concentrations of analytes were determined in human plasma as the sample matrix. The methods were compared in terms of the linearity, accuracy, repeatability, detection and quantification limits (LOD and LOQ), and recovery. The obtained validation parameters met the ICH requirements for both proposed procedures. However, the limits of detection (LOD) were much better for HPLC-QQQ-MS/MS (0.07 ng mL(-1) for trans-3 & PRIME;-hydroxcotinine; 0.02 ng mL(-1) for cotinine; 0.04 ng mL(-1) for nicotine) in comparison to the RP-HPLC-DAD enriched with chaotropic additives (1.47 ng mL(-1) for trans-3 & PRIME;-hydroxcotinine; 1.59 ng mL(-1) for cotinine; 1.50 ng mL(-1) for nicotine). The extraction efficiency (%) was concentration-dependent and ranged between 96.66% and 99.39% for RP-HPLC-DAD and 76.8% to 96.4% for HPLC-QQQ-MS/MS. The usefulness of the elaborated analytical methods was checked on the example of the analysis of a blood sample taken from a tobacco smoker. The nicotine, cotinine, and trans-3 & PRIME;-hydroxycotinine contents in the smoker's plasma quantified by the RP-HPLC-DAD method differed from the values measured by the HPLC-QQQ-MS/MS. However, the relative errors of measurements were smaller than 10% (6.80%, 6.72%, 2.04% respectively).
引用
收藏
页数:16
相关论文
共 2 条
  • [1] Rapid, sensitive, and reliable quantitation of nicotine and its main metabolites cotinine and trans-3′-hydroxycotinine by LC-MS/MS: Method development and validation for human plasma
    Mallock, Nadja
    Rabenstein, Andrea
    Laux, Peter
    Ruether, Tobias
    Hutzler, Christoph
    Parr, Maria Kristina
    Luch, Andreas
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1179
  • [2] A novel, simple and reliable method for the determination of hydronidone and its metabolites M3 and M4 in human plasma and urine by HPLC-MS/ MS and its application to a pharmacokinetic study in health Chinese subjects
    Zhang, Rui
    Li, Peixia
    Zhou, Jinping
    Guo, Pengpeng
    Liu, Yani
    Shi, Shaojun
    ANALYTICAL BIOCHEMISTRY, 2022, 655