Interleaved Variable Density Sampling With a Constrained Parallel Imaging Reconstruction for Dynamic Contrast-Enhanced MR Angiography

被引:19
作者
Wang, Kang [1 ,2 ]
Busse, Reed F. [3 ]
Holmes, James H. [2 ]
Beatty, Philip J. [4 ]
Brittain, Jean H. [2 ]
Francois, Christopher J. [5 ]
Reeder, Scott B. [1 ,5 ,6 ,7 ]
Du, Jiang [8 ]
Korosec, Frank R. [1 ,5 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
[3] GE Healthcare, MR Res, Waukesha, WI USA
[4] GE Healthcare, Global Appl Sci Lab, Thornhill, ON, Canada
[5] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[7] Univ Wisconsin, Sch Med, Madison, WI USA
[8] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
interleaved variable density sampling; constrained reconstruction; contrast-enhanced MR angiography; parallel imaging; HYCR; HYPR; PROJECTION RECONSTRUCTION; HYPR LR; RESOLUTION; BACKPROJECTION; ACQUISITION; SENSE;
D O I
10.1002/mrm.22814
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For MR applications such as contrast-enhanced MR angiography, it is desirable to achieve simultaneously high spatial and temporal resolution. The current clinical standard uses view-sharing methods combined with parallel imaging; however, this approach still provides limited spatial and temporal resolution. To improve on the clinical standard, we present an interleaved variable density (IVD) sampling method that pseudorandomly undersamples each individual frame of a 3D Cartesian k(y)-k(z) plane combined with parallel imaging acceleration. From this dataset, time-resolved images are reconstructed with a method that combines parallel imaging with a multiplicative constraint. Total acceleration factors on the order of 20 are achieved for contrast-enhanced MR angiography of the lower extremities, and improvements in temporal fidelity of the depiction of the contrast bolus passage are demonstrated relative to the clinical standard. Magn Reson Med 66:428-436, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:428 / 436
页数:9
相关论文
共 47 条
[1]  
[Anonymous], 2009, P INT SOC MAGN RES M
[2]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[3]  
Beatty PJ., 2007, Proceedings of the 15th Annual Meeting of ISMRM, P1749
[4]   Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods [J].
Brau, Anja C. S. ;
Beatty, Philip J. ;
Skare, Stefan ;
Bammer, Roland .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :382-395
[5]  
Busse R, 2009, P 17 ANN M ISMRM HAW, P2834
[6]  
BUSSE RF, 2009, P 17 ANN M ISMRM HAW, P4534
[7]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[8]   Application of reduced-encoding imaging with generalized-series reconstruction (RIGR) in dynamic MR imaging [J].
Chandra, S ;
Liang, ZP ;
Webb, A ;
Lee, H ;
Morris, HD ;
Lauterbur, PC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05) :783-797
[9]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[10]   Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction [J].
Du, J ;
Carroll, TJ ;
Brodsky, E ;
Lu, AM ;
Grist, TM ;
Mistretta, CA ;
Block, WF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :894-900